Zero Sequence Voltage using Zero Sequence Impedance (One Conductor Open) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Zero Sequence Voltage in OCO = -Zero Sequence Impedance in OCO*Zero Sequence Current in OCO
V0(oco) = -Z0(oco)*I0(oco)
This formula uses 3 Variables
Variables Used
Zero Sequence Voltage in OCO - (Measured in Volt) - Zero Sequence Voltage in OCO is consists of a balanced three-phase voltage and current, phasors of which all have the same phase angles and rotate counterclockwise together.
Zero Sequence Impedance in OCO - (Measured in Ohm) - Zero Sequence Impedance in OCO is consists of a balanced three-phase voltage and current, phasors of which all have the same phase angles and rotate counter clockwise together.
Zero Sequence Current in OCO - (Measured in Ampere) - Zero Sequence Current in OCO is consists of a balanced three-phase current, phasors of which all have the same phase angles and rotate counterclockwise together.
STEP 1: Convert Input(s) to Base Unit
Zero Sequence Impedance in OCO: 8 Ohm --> 8 Ohm No Conversion Required
Zero Sequence Current in OCO: 2.2 Ampere --> 2.2 Ampere No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
V0(oco) = -Z0(oco)*I0(oco) --> -8*2.2
Evaluating ... ...
V0(oco) = -17.6
STEP 3: Convert Result to Output's Unit
-17.6 Volt --> No Conversion Required
FINAL ANSWER
-17.6 Volt <-- Zero Sequence Voltage in OCO
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Zero Sequence Calculators

Zero Sequence Impedance using Zero Sequence Voltage (One Conductor Open)
​ LaTeX ​ Go Zero Sequence Impedance in OCO = (-1)*Zero Sequence Voltage in OCO/Zero Sequence Current in OCO
Zero Sequence Current using Zero Sequence Voltage (One Conductor Open)
​ LaTeX ​ Go Zero Sequence Current in OCO = (-1)*Zero Sequence Voltage in OCO/Zero Sequence Impedance in OCO
Zero Sequence Voltage using Zero Sequence Impedance (One Conductor Open)
​ LaTeX ​ Go Zero Sequence Voltage in OCO = -Zero Sequence Impedance in OCO*Zero Sequence Current in OCO
Zero Sequence Current (One Conductor Open)
​ LaTeX ​ Go Zero Sequence Current in OCO = (B Phase Current in OCO+C Phase Current in OCO)/3

Zero Sequence Voltage using Zero Sequence Impedance (One Conductor Open) Formula

​LaTeX ​Go
Zero Sequence Voltage in OCO = -Zero Sequence Impedance in OCO*Zero Sequence Current in OCO
V0(oco) = -Z0(oco)*I0(oco)

What are open conductor faults?

Open conductor faults are series faults that involve a break in one or two of the three conductors of a three-phase power system. The phenomenon is treated analytically through calculations and then the calculated results are confirmed through computer simulations using SIMPOW, a power system simulation software.

How to Calculate Zero Sequence Voltage using Zero Sequence Impedance (One Conductor Open)?

Zero Sequence Voltage using Zero Sequence Impedance (One Conductor Open) calculator uses Zero Sequence Voltage in OCO = -Zero Sequence Impedance in OCO*Zero Sequence Current in OCO to calculate the Zero Sequence Voltage in OCO, The Zero Sequence Voltage using Zero Sequence Impedance (One conductor open) formula is consists of a balanced three-phase voltage and current, phasors of which all have the same phase angles and rotate counterclockwise together. Zero Sequence Voltage in OCO is denoted by V0(oco) symbol.

How to calculate Zero Sequence Voltage using Zero Sequence Impedance (One Conductor Open) using this online calculator? To use this online calculator for Zero Sequence Voltage using Zero Sequence Impedance (One Conductor Open), enter Zero Sequence Impedance in OCO (Z0(oco)) & Zero Sequence Current in OCO (I0(oco)) and hit the calculate button. Here is how the Zero Sequence Voltage using Zero Sequence Impedance (One Conductor Open) calculation can be explained with given input values -> -17.446 = -8*2.2.

FAQ

What is Zero Sequence Voltage using Zero Sequence Impedance (One Conductor Open)?
The Zero Sequence Voltage using Zero Sequence Impedance (One conductor open) formula is consists of a balanced three-phase voltage and current, phasors of which all have the same phase angles and rotate counterclockwise together and is represented as V0(oco) = -Z0(oco)*I0(oco) or Zero Sequence Voltage in OCO = -Zero Sequence Impedance in OCO*Zero Sequence Current in OCO. Zero Sequence Impedance in OCO is consists of a balanced three-phase voltage and current, phasors of which all have the same phase angles and rotate counter clockwise together & Zero Sequence Current in OCO is consists of a balanced three-phase current, phasors of which all have the same phase angles and rotate counterclockwise together.
How to calculate Zero Sequence Voltage using Zero Sequence Impedance (One Conductor Open)?
The Zero Sequence Voltage using Zero Sequence Impedance (One conductor open) formula is consists of a balanced three-phase voltage and current, phasors of which all have the same phase angles and rotate counterclockwise together is calculated using Zero Sequence Voltage in OCO = -Zero Sequence Impedance in OCO*Zero Sequence Current in OCO. To calculate Zero Sequence Voltage using Zero Sequence Impedance (One Conductor Open), you need Zero Sequence Impedance in OCO (Z0(oco)) & Zero Sequence Current in OCO (I0(oco)). With our tool, you need to enter the respective value for Zero Sequence Impedance in OCO & Zero Sequence Current in OCO and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!