Zero Sequence Current for Star Connected Load Solution

STEP 0: Pre-Calculation Summary
Formula Used
Zero Sequence Current = Zero Sequence Voltage/(Star Impedance+(3*Fault Impedance))
I0 = V0/(Zy+(3*Zf))
This formula uses 4 Variables
Variables Used
Zero Sequence Current - (Measured in Ampere) - Zero Sequence Current is consists of a balanced three-phase current, phasors of which all have the same phase angles and rotate counterclockwise together.
Zero Sequence Voltage - (Measured in Volt) - Zero Sequence Voltage is consists of a balanced three-phase voltage and current, phasors of which all have the same phase angles and rotate counterclockwise together.
Star Impedance - (Measured in Ohm) - Star Impedance is defined as the impedance Of star connected network.
Fault Impedance - (Measured in Ohm) - Fault Impedance is defined as the impedance that caused the fault.
STEP 1: Convert Input(s) to Base Unit
Zero Sequence Voltage: 60.59 Volt --> 60.59 Volt No Conversion Required
Star Impedance: 4.12 Ohm --> 4.12 Ohm No Conversion Required
Fault Impedance: 7.86 Ohm --> 7.86 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
I0 = V0/(Zy+(3*Zf)) --> 60.59/(4.12+(3*7.86))
Evaluating ... ...
I0 = 2.18736462093863
STEP 3: Convert Result to Output's Unit
2.18736462093863 Ampere --> No Conversion Required
FINAL ANSWER
2.18736462093863 2.187365 Ampere <-- Zero Sequence Current
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

Sequence Current and Voltage Calculators

Zero Sequence Voltage for Star Connected Load
​ LaTeX ​ Go Zero Sequence Voltage = (Star Impedance+3*Fault Impedance)*Zero Sequence Current
Positive Sequence Voltage for Delta Connected Load
​ LaTeX ​ Go Positive Sequence Voltage = (Delta Impedance*Positive Sequence Current)/3
Negative Sequence Voltage for Star Connected Load
​ LaTeX ​ Go Negative Sequence Voltage = Negative Sequence Current*Star Impedance
Positive Sequence Voltage for Star Connected Load
​ LaTeX ​ Go Positive Sequence Voltage = Star Impedance*Positive Sequence Current

Zero Sequence Current for Star Connected Load Formula

​LaTeX ​Go
Zero Sequence Current = Zero Sequence Voltage/(Star Impedance+(3*Fault Impedance))
I0 = V0/(Zy+(3*Zf))

What is the zero-Sequence Current?

The unbalanced current flows in the circuit during the earth fault is known as the zero-sequence current or the DC component of the fault current. The zero phase sequence means the magnitude of three phases has zero phase displacement.

How to Calculate Zero Sequence Current for Star Connected Load?

Zero Sequence Current for Star Connected Load calculator uses Zero Sequence Current = Zero Sequence Voltage/(Star Impedance+(3*Fault Impedance)) to calculate the Zero Sequence Current, The Zero Sequence Current for Star Connected Load formula consists of a balanced three-phase current, phasors of which all have the same phase angles and rotate counterclockwise together. Zero Sequence Current is denoted by I0 symbol.

How to calculate Zero Sequence Current for Star Connected Load using this online calculator? To use this online calculator for Zero Sequence Current for Star Connected Load, enter Zero Sequence Voltage (V0), Star Impedance (Zy) & Fault Impedance (Zf) and hit the calculate button. Here is how the Zero Sequence Current for Star Connected Load calculation can be explained with given input values -> 2.189736 = 60.59/(4.12+(3*7.86)).

FAQ

What is Zero Sequence Current for Star Connected Load?
The Zero Sequence Current for Star Connected Load formula consists of a balanced three-phase current, phasors of which all have the same phase angles and rotate counterclockwise together and is represented as I0 = V0/(Zy+(3*Zf)) or Zero Sequence Current = Zero Sequence Voltage/(Star Impedance+(3*Fault Impedance)). Zero Sequence Voltage is consists of a balanced three-phase voltage and current, phasors of which all have the same phase angles and rotate counterclockwise together, Star Impedance is defined as the impedance Of star connected network & Fault Impedance is defined as the impedance that caused the fault.
How to calculate Zero Sequence Current for Star Connected Load?
The Zero Sequence Current for Star Connected Load formula consists of a balanced three-phase current, phasors of which all have the same phase angles and rotate counterclockwise together is calculated using Zero Sequence Current = Zero Sequence Voltage/(Star Impedance+(3*Fault Impedance)). To calculate Zero Sequence Current for Star Connected Load, you need Zero Sequence Voltage (V0), Star Impedance (Zy) & Fault Impedance (Zf). With our tool, you need to enter the respective value for Zero Sequence Voltage, Star Impedance & Fault Impedance and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.