Zero Bias Sidewall Junction Capacitance per Unit Length Solution

STEP 0: Pre-Calculation Summary
Formula Used
Sidewall Junction Capacitance = Zero Bias Sidewall Junction Potential*Depth of Sidewall
Cjsw = Cj0sw*xj
This formula uses 3 Variables
Variables Used
Sidewall Junction Capacitance - (Measured in Farad) - Sidewall Junction Capacitance refers to the capacitance associated with the sidewall of a semiconductor junction.
Zero Bias Sidewall Junction Potential - (Measured in Farad) - Zero Bias Sidewall Junction Potential is the built-in potential in the sidewall junction of certain transistor structures.
Depth of Sidewall - (Measured in Meter) - Depth of Sidewall refers to the distance from the surface of a structure or material to a specified point within the sidewall.
STEP 1: Convert Input(s) to Base Unit
Zero Bias Sidewall Junction Potential: 4.6E-10 Farad --> 4.6E-10 Farad No Conversion Required
Depth of Sidewall: 6.32 Micrometer --> 6.32E-06 Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Cjsw = Cj0sw*xj --> 4.6E-10*6.32E-06
Evaluating ... ...
Cjsw = 2.9072E-15
STEP 3: Convert Result to Output's Unit
2.9072E-15 Farad --> No Conversion Required
FINAL ANSWER
2.9072E-15 2.9E-15 Farad <-- Sidewall Junction Capacitance
(Calculation completed in 00.021 seconds)

Credits

Creator Image
Created by banuprakash
Dayananda Sagar College of Engineering (DSCE), Bangalore
banuprakash has created this Calculator and 50+ more calculators!
Verifier Image
Verified by Dipanjona Mallick
Heritage Insitute of technology (HITK), Kolkata
Dipanjona Mallick has verified this Calculator and 50+ more calculators!

MOS Transistor Calculators

Sidewall Voltage Equivalence Factor
​ LaTeX ​ Go Sidewall Voltage Equivalence Factor = -(2*sqrt(Built in Potential of Sidewall Junctions)/(Final Voltage-Initial Voltage)*(sqrt(Built in Potential of Sidewall Junctions-Final Voltage)-sqrt(Built in Potential of Sidewall Junctions-Initial Voltage)))
Fermi Potential for P Type
​ LaTeX ​ Go Fermi Potential for P Type = ([BoltZ]*Absolute Temperature)/[Charge-e]*ln(Intrinsic Carrier Concentration/Doping Concentration of Acceptor)
Equivalent Large Signal Junction Capacitance
​ LaTeX ​ Go Equivalent Large Signal Junction Capacitance = Perimeter of Sidewall*Sidewall Junction Capacitance*Sidewall Voltage Equivalence Factor
Zero Bias Sidewall Junction Capacitance per Unit Length
​ LaTeX ​ Go Sidewall Junction Capacitance = Zero Bias Sidewall Junction Potential*Depth of Sidewall

Zero Bias Sidewall Junction Capacitance per Unit Length Formula

​LaTeX ​Go
Sidewall Junction Capacitance = Zero Bias Sidewall Junction Potential*Depth of Sidewall
Cjsw = Cj0sw*xj

How is sidewall capacitance related to the overall capacitance of a transistor?

Sidewall capacitance contributes to the overall capacitance of a transistor, which is a crucial parameter in determining the device's speed and power consumption.

How to Calculate Zero Bias Sidewall Junction Capacitance per Unit Length?

Zero Bias Sidewall Junction Capacitance per Unit Length calculator uses Sidewall Junction Capacitance = Zero Bias Sidewall Junction Potential*Depth of Sidewall to calculate the Sidewall Junction Capacitance, The Zero Bias Sidewall Junction Capacitance per Unit Length formula is defined as the capacitance associated with the sidewall of a semiconductor junction. Sidewall Junction Capacitance is denoted by Cjsw symbol.

How to calculate Zero Bias Sidewall Junction Capacitance per Unit Length using this online calculator? To use this online calculator for Zero Bias Sidewall Junction Capacitance per Unit Length, enter Zero Bias Sidewall Junction Potential (Cj0sw) & Depth of Sidewall (xj) and hit the calculate button. Here is how the Zero Bias Sidewall Junction Capacitance per Unit Length calculation can be explained with given input values -> 2.9E-15 = 4.6E-10*6.32E-06.

FAQ

What is Zero Bias Sidewall Junction Capacitance per Unit Length?
The Zero Bias Sidewall Junction Capacitance per Unit Length formula is defined as the capacitance associated with the sidewall of a semiconductor junction and is represented as Cjsw = Cj0sw*xj or Sidewall Junction Capacitance = Zero Bias Sidewall Junction Potential*Depth of Sidewall. Zero Bias Sidewall Junction Potential is the built-in potential in the sidewall junction of certain transistor structures & Depth of Sidewall refers to the distance from the surface of a structure or material to a specified point within the sidewall.
How to calculate Zero Bias Sidewall Junction Capacitance per Unit Length?
The Zero Bias Sidewall Junction Capacitance per Unit Length formula is defined as the capacitance associated with the sidewall of a semiconductor junction is calculated using Sidewall Junction Capacitance = Zero Bias Sidewall Junction Potential*Depth of Sidewall. To calculate Zero Bias Sidewall Junction Capacitance per Unit Length, you need Zero Bias Sidewall Junction Potential (Cj0sw) & Depth of Sidewall (xj). With our tool, you need to enter the respective value for Zero Bias Sidewall Junction Potential & Depth of Sidewall and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!