Y22 Parameter in Terms of T Parameters Solution

STEP 0: Pre-Calculation Summary
Formula Used
Y22 Parameter = A Parameter/B Parameter
Y22 = A/B
This formula uses 3 Variables
Variables Used
Y22 Parameter - (Measured in Siemens) - Y22 Parameter is driving point Admittance at port 2.
A Parameter - A parameter is a generalized line constant.
B Parameter - (Measured in Ohm) - B parameter is a generalized line constant. also known as short circuit resistance.
STEP 1: Convert Input(s) to Base Unit
A Parameter: 4.6 --> No Conversion Required
B Parameter: 15 Ohm --> 15 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Y22 = A/B --> 4.6/15
Evaluating ... ...
Y22 = 0.306666666666667
STEP 3: Convert Result to Output's Unit
0.306666666666667 Siemens -->0.306666666666667 Mho (Check conversion ​here)
FINAL ANSWER
0.306666666666667 0.306667 Mho <-- Y22 Parameter
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Y Parameters Calculators

Driving Point Output Admittance (Y22)
​ LaTeX ​ Go Y22 Parameter = Current in Port 2/Voltage Port 2
Driving Point Input Admittance (Y11)
​ LaTeX ​ Go Y11 Parameter = Current in Port 1/Voltage Port 1
Output Transfer Admittance (Y21)
​ LaTeX ​ Go Y21 Parameter = Current in Port 2/Voltage Port 1
Input Transfer Admittance (Y12)
​ LaTeX ​ Go Y12 Parameter = Current in Port 1/Voltage Port 2

Y22 Parameter in Terms of T Parameters Formula

​LaTeX ​Go
Y22 Parameter = A Parameter/B Parameter
Y22 = A/B

Define two-port network.

A two-port network has four variables with two of them being independent. If one of the ports is terminated by a load with no independent sources, then the load enforces a relationship between the voltage and current of that port. A degree of freedom is lost. The circuit now has only one independent parameter.

How to Calculate Y22 Parameter in Terms of T Parameters?

Y22 Parameter in Terms of T Parameters calculator uses Y22 Parameter = A Parameter/B Parameter to calculate the Y22 Parameter, The Y22 Parameter in Terms of T Parameters formula is defined as driving point Admittance at the port-2 of the short circuit admittance parameters. Y22 Parameter is denoted by Y22 symbol.

How to calculate Y22 Parameter in Terms of T Parameters using this online calculator? To use this online calculator for Y22 Parameter in Terms of T Parameters, enter A Parameter (A) & B Parameter (B) and hit the calculate button. Here is how the Y22 Parameter in Terms of T Parameters calculation can be explained with given input values -> 0.306667 = 4.6/15.

FAQ

What is Y22 Parameter in Terms of T Parameters?
The Y22 Parameter in Terms of T Parameters formula is defined as driving point Admittance at the port-2 of the short circuit admittance parameters and is represented as Y22 = A/B or Y22 Parameter = A Parameter/B Parameter. A parameter is a generalized line constant & B parameter is a generalized line constant. also known as short circuit resistance.
How to calculate Y22 Parameter in Terms of T Parameters?
The Y22 Parameter in Terms of T Parameters formula is defined as driving point Admittance at the port-2 of the short circuit admittance parameters is calculated using Y22 Parameter = A Parameter/B Parameter. To calculate Y22 Parameter in Terms of T Parameters, you need A Parameter (A) & B Parameter (B). With our tool, you need to enter the respective value for A Parameter & B Parameter and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Y22 Parameter?
In this formula, Y22 Parameter uses A Parameter & B Parameter. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Y22 Parameter = Current in Port 2/Voltage Port 2
  • Y22 Parameter = Z11 Parameter/Delta-Z
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!