XOR Phase Detector Phase with reference to Detector Current Solution

STEP 0: Pre-Calculation Summary
Formula Used
XOR Phase Detector Phase = XOR Phase Detector Current/XOR Phase Detector Average Voltage
Φerr = ipd/Kpd
This formula uses 3 Variables
Variables Used
XOR Phase Detector Phase - (Measured in Radian) - XOR Phase Detector Phase where phase detector is a frequency mixer, an analog multiplier that generates a voltage signal which represents the difference in phase between two signal inputs.
XOR Phase Detector Current - (Measured in Ampere) - XOR Phase Detector Current is defined as an electric current(which is a stream of charged particles, such as electrons or ions)moving through an electrical conductor or space.
XOR Phase Detector Average Voltage - (Measured in Volt) - XOR Phase Detector Average Voltage is the averaging of all the instantaneous values along the time axis with time being one full period, (T).
STEP 1: Convert Input(s) to Base Unit
XOR Phase Detector Current: 499.93 Milliampere --> 0.49993 Ampere (Check conversion ​here)
XOR Phase Detector Average Voltage: 3.08 Volt --> 3.08 Volt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Φerr = ipd/Kpd --> 0.49993/3.08
Evaluating ... ...
Φerr = 0.162314935064935
STEP 3: Convert Result to Output's Unit
0.162314935064935 Radian -->9.29996073116254 Degree (Check conversion ​here)
FINAL ANSWER
9.29996073116254 9.299961 Degree <-- XOR Phase Detector Phase
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Shobhit Dimri
Bipin Tripathi Kumaon Institute of Technology (BTKIT), Dwarahat
Shobhit Dimri has created this Calculator and 900+ more calculators!
Verifier Image
Verified by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has verified this Calculator and 1900+ more calculators!

CMOS Time Characteristics Calculators

Aperture Time for Falling Input
​ LaTeX ​ Go Aperture Time for Falling Input = Setup Time at Low Logic+Hold Time at High Logic
Setup Time at Low Logic
​ LaTeX ​ Go Setup Time at Low Logic = Aperture Time for Falling Input-Hold Time at High Logic
Aperture Time for Rising Input
​ LaTeX ​ Go Aperture Time for Rising Input = Setup Time at High Logic+Hold Time at Low Logic
Setup Time at High Logic
​ LaTeX ​ Go Setup Time at High Logic = Aperture Time for Rising Input-Hold Time at Low Logic

XOR Phase Detector Phase with reference to Detector Current Formula

​LaTeX ​Go
XOR Phase Detector Phase = XOR Phase Detector Current/XOR Phase Detector Average Voltage
Φerr = ipd/Kpd

What is XOR Gate?

XOR gate (sometimes EOR, or EXOR and pronounced as Exclusive OR) is a digital logic gate that gives a true (1 or HIGH) output when the number of true inputs is odd. An XOR gate implements an exclusive or; that is, a true output results if one, and only one, of the inputs to the gate is true.

How to Calculate XOR Phase Detector Phase with reference to Detector Current?

XOR Phase Detector Phase with reference to Detector Current calculator uses XOR Phase Detector Phase = XOR Phase Detector Current/XOR Phase Detector Average Voltage to calculate the XOR Phase Detector Phase, XOR Phase Detector Phase with reference to Detector Current can be described by a transfer function that relates the input phase difference to the output current. This transfer function determines how the phase detector responds to different phase differences and generates the corresponding output current. XOR Phase Detector Phase is denoted by Φerr symbol.

How to calculate XOR Phase Detector Phase with reference to Detector Current using this online calculator? To use this online calculator for XOR Phase Detector Phase with reference to Detector Current, enter XOR Phase Detector Current (ipd) & XOR Phase Detector Average Voltage (Kpd) and hit the calculate button. Here is how the XOR Phase Detector Phase with reference to Detector Current calculation can be explained with given input values -> 532.8485 = 0.49993/3.08.

FAQ

What is XOR Phase Detector Phase with reference to Detector Current?
XOR Phase Detector Phase with reference to Detector Current can be described by a transfer function that relates the input phase difference to the output current. This transfer function determines how the phase detector responds to different phase differences and generates the corresponding output current and is represented as Φerr = ipd/Kpd or XOR Phase Detector Phase = XOR Phase Detector Current/XOR Phase Detector Average Voltage. XOR Phase Detector Current is defined as an electric current(which is a stream of charged particles, such as electrons or ions)moving through an electrical conductor or space & XOR Phase Detector Average Voltage is the averaging of all the instantaneous values along the time axis with time being one full period, (T).
How to calculate XOR Phase Detector Phase with reference to Detector Current?
XOR Phase Detector Phase with reference to Detector Current can be described by a transfer function that relates the input phase difference to the output current. This transfer function determines how the phase detector responds to different phase differences and generates the corresponding output current is calculated using XOR Phase Detector Phase = XOR Phase Detector Current/XOR Phase Detector Average Voltage. To calculate XOR Phase Detector Phase with reference to Detector Current, you need XOR Phase Detector Current (ipd) & XOR Phase Detector Average Voltage (Kpd). With our tool, you need to enter the respective value for XOR Phase Detector Current & XOR Phase Detector Average Voltage and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate XOR Phase Detector Phase?
In this formula, XOR Phase Detector Phase uses XOR Phase Detector Current & XOR Phase Detector Average Voltage. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • XOR Phase Detector Phase = XOR Phase Detector Voltage/XOR Phase Detector Average Voltage
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!