Width of Throat given Discharge through Control Section Solution

STEP 0: Pre-Calculation Summary
Formula Used
Width of Throat = (Environmental Discharge/(Critical Depth*Critical Velocity))
Wt = (Qe/(dc*Vc))
This formula uses 4 Variables
Variables Used
Width of Throat - (Measured in Meter) - Width of Throat is the narrowest section of a conduit or channel, such as in a venturi meter or flume.
Environmental Discharge - (Measured in Cubic Meter per Second) - Environmental Discharge is the rate of flow of a liquid.
Critical Depth - (Measured in Meter) - Critical Depth occurs when the flow in a channel has a minimum specific energy. Specific energy refers to the sum of the depth of flow and the velocity head.
Critical Velocity - (Measured in Meter per Second) - The Critical velocity is the greatest velocity with which a fluid can flow through a given conduit without becoming turbulent.
STEP 1: Convert Input(s) to Base Unit
Environmental Discharge: 39.82 Cubic Meter per Second --> 39.82 Cubic Meter per Second No Conversion Required
Critical Depth: 2.62 Meter --> 2.62 Meter No Conversion Required
Critical Velocity: 5.06 Meter per Second --> 5.06 Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Wt = (Qe/(dc*Vc)) --> (39.82/(2.62*5.06))
Evaluating ... ...
Wt = 3.00365084633256
STEP 3: Convert Result to Output's Unit
3.00365084633256 Meter --> No Conversion Required
FINAL ANSWER
3.00365084633256 3.003651 Meter <-- Width of Throat
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Width of Channel Calculators

Width of Throat given Critical Depth
​ LaTeX ​ Go Width of Throat = sqrt((Environmental Discharge)^2/(Acceleration due to Gravity*(Critical Depth)^3))
Width of Throat given Discharge through Control Section
​ LaTeX ​ Go Width of Throat = (Environmental Discharge/(Critical Depth*Critical Velocity))
Width of Throat given Maximum Discharge
​ LaTeX ​ Go Width of Throat = (Peak Discharge/(Critical Depth*Critical Velocity))
Width of Parabolic Channel
​ LaTeX ​ Go Width = (1.5*Area of Cross Section)/Depth

Width of Throat given Discharge through Control Section Formula

​LaTeX ​Go
Width of Throat = (Environmental Discharge/(Critical Depth*Critical Velocity))
Wt = (Qe/(dc*Vc))

What is Critical Velocity?

The velocity at which flow transitions from being subcritical to supercritical. In open channel flow, critical velocity occurs when the flow's kinetic energy is equal to the potential energy. It's a point where the flow is neither too fast nor too slow, and it determines the efficiency and behavior of the channel.

How to Calculate Width of Throat given Discharge through Control Section?

Width of Throat given Discharge through Control Section calculator uses Width of Throat = (Environmental Discharge/(Critical Depth*Critical Velocity)) to calculate the Width of Throat, The Width of Throat given Discharge through Control Section formula is defined as the value of the narrowest part of a flow control structure, such as the constriction in a flume or weir. Width of Throat is denoted by Wt symbol.

How to calculate Width of Throat given Discharge through Control Section using this online calculator? To use this online calculator for Width of Throat given Discharge through Control Section, enter Environmental Discharge (Qe), Critical Depth (dc) & Critical Velocity (Vc) and hit the calculate button. Here is how the Width of Throat given Discharge through Control Section calculation can be explained with given input values -> 3.017228 = (39.82/(2.62*5.06)).

FAQ

What is Width of Throat given Discharge through Control Section?
The Width of Throat given Discharge through Control Section formula is defined as the value of the narrowest part of a flow control structure, such as the constriction in a flume or weir and is represented as Wt = (Qe/(dc*Vc)) or Width of Throat = (Environmental Discharge/(Critical Depth*Critical Velocity)). Environmental Discharge is the rate of flow of a liquid, Critical Depth occurs when the flow in a channel has a minimum specific energy. Specific energy refers to the sum of the depth of flow and the velocity head & The Critical velocity is the greatest velocity with which a fluid can flow through a given conduit without becoming turbulent.
How to calculate Width of Throat given Discharge through Control Section?
The Width of Throat given Discharge through Control Section formula is defined as the value of the narrowest part of a flow control structure, such as the constriction in a flume or weir is calculated using Width of Throat = (Environmental Discharge/(Critical Depth*Critical Velocity)). To calculate Width of Throat given Discharge through Control Section, you need Environmental Discharge (Qe), Critical Depth (dc) & Critical Velocity (Vc). With our tool, you need to enter the respective value for Environmental Discharge, Critical Depth & Critical Velocity and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Width of Throat?
In this formula, Width of Throat uses Environmental Discharge, Critical Depth & Critical Velocity. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Width of Throat = sqrt((Environmental Discharge)^2/(Acceleration due to Gravity*(Critical Depth)^3))
  • Width of Throat = (Peak Discharge/(Critical Depth*Critical Velocity))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!