Width of Tank given Vertical Falling Speed in Sedimentation Tank Solution

STEP 0: Pre-Calculation Summary
Formula Used
Width = Discharge/(Settling Velocity*Length)
w = Q/(Vs*L)
This formula uses 4 Variables
Variables Used
Width - (Measured in Meter) - The Width of a sedimentation tank refers to the horizontal dimension across the tank, typically measured perpendicular to the flow of water in a rectangular tank.
Discharge - (Measured in Cubic Meter per Second) - The Discharge refers to the volume of fluid (usually water) that flows through a given cross-sectional area per unit of time.
Settling Velocity - (Measured in Meter per Second) - The Settling Velocity refers to the rate at which a particle suspended in a fluid (like water or air) falls under the influence of gravity until reaches a constant speed.
Length - (Measured in Meter) - The Length refers to the measurement of the distance between two points.
STEP 1: Convert Input(s) to Base Unit
Discharge: 1.01 Cubic Meter per Second --> 1.01 Cubic Meter per Second No Conversion Required
Settling Velocity: 1.5 Meter per Second --> 1.5 Meter per Second No Conversion Required
Length: 5 Meter --> 5 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
w = Q/(Vs*L) --> 1.01/(1.5*5)
Evaluating ... ...
w = 0.134666666666667
STEP 3: Convert Result to Output's Unit
0.134666666666667 Meter --> No Conversion Required
FINAL ANSWER
0.134666666666667 0.134667 Meter <-- Width
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 500+ more calculators!

Vertical Falling Speed Calculators

Vertical Falling Speed given Height at Outlet Zone with respect to Discharge
​ LaTeX ​ Go Falling Speed = Outer Height*Discharge/(Length*Width*Height of Crack)
Vertical Falling Speed given Height at Outlet Zone with respect to Settling Velocity
​ LaTeX ​ Go Falling Speed = Outer Height*(Settling Velocity/Height of Crack)
Width of Tank given Vertical Falling Speed in Sedimentation Tank
​ LaTeX ​ Go Width = Discharge/(Settling Velocity*Length)
Vertical Falling Speed in Sedimentation Tank
​ LaTeX ​ Go Settling Velocity = Discharge/(Length*Width)

Width of Tank given Vertical Falling Speed in Sedimentation Tank Formula

​LaTeX ​Go
Width = Discharge/(Settling Velocity*Length)
w = Q/(Vs*L)

What is Sedimentation?

Sedimentation is the tendency for particles in suspension to settle out of the fluid in which they are entrained and come to rest against a barrier. This is due to their motion through the fluid in response to the forces acting on them: these forces can be due to gravity, centrifugal acceleration, or electromagnetism.

How to Calculate Width of Tank given Vertical Falling Speed in Sedimentation Tank?

Width of Tank given Vertical Falling Speed in Sedimentation Tank calculator uses Width = Discharge/(Settling Velocity*Length) to calculate the Width, The Width of Tank given Vertical Falling Speed in Sedimentation Tank formula is defined as the horizontal distance across the tank perpendicular to the flow direction. In a rectangular tank, this is the shorter side dimension, while in a circular tank, it would correspond to the diameter. Width is denoted by w symbol.

How to calculate Width of Tank given Vertical Falling Speed in Sedimentation Tank using this online calculator? To use this online calculator for Width of Tank given Vertical Falling Speed in Sedimentation Tank, enter Discharge (Q), Settling Velocity (Vs) & Length (L) and hit the calculate button. Here is how the Width of Tank given Vertical Falling Speed in Sedimentation Tank calculation can be explained with given input values -> 0.134667 = 1.01/(1.5*5).

FAQ

What is Width of Tank given Vertical Falling Speed in Sedimentation Tank?
The Width of Tank given Vertical Falling Speed in Sedimentation Tank formula is defined as the horizontal distance across the tank perpendicular to the flow direction. In a rectangular tank, this is the shorter side dimension, while in a circular tank, it would correspond to the diameter and is represented as w = Q/(Vs*L) or Width = Discharge/(Settling Velocity*Length). The Discharge refers to the volume of fluid (usually water) that flows through a given cross-sectional area per unit of time, The Settling Velocity refers to the rate at which a particle suspended in a fluid (like water or air) falls under the influence of gravity until reaches a constant speed & The Length refers to the measurement of the distance between two points.
How to calculate Width of Tank given Vertical Falling Speed in Sedimentation Tank?
The Width of Tank given Vertical Falling Speed in Sedimentation Tank formula is defined as the horizontal distance across the tank perpendicular to the flow direction. In a rectangular tank, this is the shorter side dimension, while in a circular tank, it would correspond to the diameter is calculated using Width = Discharge/(Settling Velocity*Length). To calculate Width of Tank given Vertical Falling Speed in Sedimentation Tank, you need Discharge (Q), Settling Velocity (Vs) & Length (L). With our tool, you need to enter the respective value for Discharge, Settling Velocity & Length and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!