How to Calculate Width of Strip Footing given Net Ultimate Bearing Capacity?
Width of Strip Footing given Net Ultimate Bearing Capacity calculator uses Width of Footing = (Net Ultimate BC-((Cohesion in Soil as Kilopascal*Bearing Capacity Factor dependent on Cohesion)+(Effective Surcharge in KiloPascal*(Bearing Capacity Factor dependent on Surcharge-1))))/(0.5*Unit Weight of Soil*Bearing Capacity Factor dependent on Unit Weight) to calculate the Width of Footing, The Width of Strip Footing given Net Ultimate Bearing Capacity is defined as the value of width of footing when we have prior information of other parameters used. Width of Footing is denoted by B symbol.
How to calculate Width of Strip Footing given Net Ultimate Bearing Capacity using this online calculator? To use this online calculator for Width of Strip Footing given Net Ultimate Bearing Capacity, enter Net Ultimate BC (qnu), Cohesion in Soil as Kilopascal (C), Bearing Capacity Factor dependent on Cohesion (Nc), Effective Surcharge in KiloPascal (σs), Bearing Capacity Factor dependent on Surcharge (Nq), Unit Weight of Soil (γ) & Bearing Capacity Factor dependent on Unit Weight (Nγ) and hit the calculate button. Here is how the Width of Strip Footing given Net Ultimate Bearing Capacity calculation can be explained with given input values -> 2.060417 = (87000-((1270*9)+(45900*(2.01-1))))/(0.5*18000*1.6).