Wet Bulb Temperature Solution

STEP 0: Pre-Calculation Summary
Formula Used
Wet Bulb Temperature = Temperature of Air-(Air Humidity at Wet Bulb Temperature-Ambient Air Humidity)*((Mass Transfer Coefficient of the Moisture*Heat of Vaporization at Wet Bulb Temperature)/Heat Transfer Coefficient of the Air Film)
TW = TG-(YW'-YA)*((kY'*λW)/hG)
This formula uses 7 Variables
Variables Used
Wet Bulb Temperature - (Measured in Kelvin) - Wet bulb temperature is the lowest temperature attainable by evaporating water into air at constant pressure.
Temperature of Air - (Measured in Kelvin) - The Temperature of Air is defined as the temperature at which the air-water mixture properties in humidification are calculated.
Air Humidity at Wet Bulb Temperature - (Measured in Kg of water vapour per Kg of air) - Air humidity at Wet Bulb Temperature refers to the moisture content present in the surrounding air at a given location at the Wet Bulb temperature.
Ambient Air Humidity - (Measured in Kg of water vapour per Kg of air) - Ambient air humidity refers to the moisture content present in the surrounding air at a given location an temperature.
Mass Transfer Coefficient of the Moisture - (Measured in Mole per Second Square Meter) - Mass Transfer Coefficient of the Moisture is the proportionality factor between the mass transfer rate and the concentration driving force.
Heat of Vaporization at Wet Bulb Temperature - (Measured in Joule per Kilogram) - The heat of vaporization at wet bulb temperature is the energy required per unit mass to convert liquid water into vapor at the wet bulb temperature of the gas liquid mixture.
Heat Transfer Coefficient of the Air Film - (Measured in Watt per Square Meter per Kelvin) - Heat Transfer Coefficient of the Air Film is the proportionality factor between the heat transfer rate and the temperature driving force.
STEP 1: Convert Input(s) to Base Unit
Temperature of Air: 30 Celsius --> 303.15 Kelvin (Check conversion ​here)
Air Humidity at Wet Bulb Temperature: 0.021 Kg of water vapour per Kg of air --> 0.021 Kg of water vapour per Kg of air No Conversion Required
Ambient Air Humidity: 0.016 Kg of water vapour per Kg of air --> 0.016 Kg of water vapour per Kg of air No Conversion Required
Mass Transfer Coefficient of the Moisture: 0.01 Mole per Second Square Meter --> 0.01 Mole per Second Square Meter No Conversion Required
Heat of Vaporization at Wet Bulb Temperature: 2250 Kilojoule per Kilogram --> 2250000 Joule per Kilogram (Check conversion ​here)
Heat Transfer Coefficient of the Air Film: 13.32 Watt per Square Meter per Kelvin --> 13.32 Watt per Square Meter per Kelvin No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
TW = TG-(YW'-YA)*((kY'*λW)/hG) --> 303.15-(0.021-0.016)*((0.01*2250000)/13.32)
Evaluating ... ...
TW = 294.704054054054
STEP 3: Convert Result to Output's Unit
294.704054054054 Kelvin -->21.5540540540541 Celsius (Check conversion ​here)
FINAL ANSWER
21.5540540540541 21.55405 Celsius <-- Wet Bulb Temperature
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Vaibhav Mishra
DJ Sanghvi College of Engineering (DJSCE), Mumbai
Vaibhav Mishra has created this Calculator and 300+ more calculators!
Verifier Image
Verified by Heet
Thadomal Shahani Engineering College (Tsec), Mumbai
Heet has verified this Calculator and 25+ more calculators!

Adiabatic Saturation Temperature and Wet Bulb Temperature Calculators

Air Inlet Temperature based on Adiabatic Saturation Temperature
​ LaTeX ​ Go Temperature of Air = (Saturated Exit Air Humidity-Inlet Air Humidity)*(Heat of Vaporization at Adiabatic Saturation Temp/Humid Heat)+Adiabatic Saturation Temperature
Latent Heat of Air based on Adiabatic Saturation Temperature
​ LaTeX ​ Go Heat of Vaporization at Adiabatic Saturation Temp = (Temperature of Air-Adiabatic Saturation Temperature)/(Saturated Exit Air Humidity-Inlet Air Humidity)*Humid Heat
Humid Heat of Air based on Adiabatic Saturation Temperature
​ LaTeX ​ Go Humid Heat = (Saturated Exit Air Humidity-Inlet Air Humidity)/(Temperature of Air-Adiabatic Saturation Temperature)*Heat of Vaporization at Adiabatic Saturation Temp
Adiabatic Saturation Temperature
​ LaTeX ​ Go Adiabatic Saturation Temperature = Temperature of Air-(Saturated Exit Air Humidity-Inlet Air Humidity)*(Heat of Vaporization at Adiabatic Saturation Temp/Humid Heat)

Wet Bulb Temperature Formula

​LaTeX ​Go
Wet Bulb Temperature = Temperature of Air-(Air Humidity at Wet Bulb Temperature-Ambient Air Humidity)*((Mass Transfer Coefficient of the Moisture*Heat of Vaporization at Wet Bulb Temperature)/Heat Transfer Coefficient of the Air Film)
TW = TG-(YW'-YA)*((kY'*λW)/hG)

What is Wet Bulb Temperature?

Wet bulb temperature is the lowest temperature that can be achieved by evaporating water into air at constant pressure, measured using a thermometer with its bulb covered by a wet cloth. It provides insights into the cooling potential of air through evaporation and is a key parameter in psychrometrics, commonly used in HVAC engineering and meteorology. Wet bulb temperature helps assess humidity levels, determine dew point, and evaluate the efficiency of cooling processes without direct application mentioned.

What is Humidification Process?

The humidification process involves adding moisture to indoor air to increase its relative humidity. It begins by measuring the current humidity level using a hygrometer. A desired humidity level is set, typically between 30% and 60%. Different humidification methods like evaporative, steam, or ultrasonic are chosen based on space requirements. The humidifier, often equipped with a humidistat, is then operated to release moisture. As the humidifier maintains the setpoint, it continuously monitors and controls humidity levels. Regular maintenance is essential to prevent issues and ensure safe and effective operation, especially in dry environments or during winter when indoor heating can dry out the air.

How to Calculate Wet Bulb Temperature?

Wet Bulb Temperature calculator uses Wet Bulb Temperature = Temperature of Air-(Air Humidity at Wet Bulb Temperature-Ambient Air Humidity)*((Mass Transfer Coefficient of the Moisture*Heat of Vaporization at Wet Bulb Temperature)/Heat Transfer Coefficient of the Air Film) to calculate the Wet Bulb Temperature, The Wet Bulb Temperature formula is defined as the lowest temperature of air that is possible if water if added at constant pressure in air-water mixture. Wet Bulb Temperature is denoted by TW symbol.

How to calculate Wet Bulb Temperature using this online calculator? To use this online calculator for Wet Bulb Temperature, enter Temperature of Air (TG), Air Humidity at Wet Bulb Temperature (YW'), Ambient Air Humidity (YA), Mass Transfer Coefficient of the Moisture (kY'), Heat of Vaporization at Wet Bulb Temperature W) & Heat Transfer Coefficient of the Air Film (hG) and hit the calculate button. Here is how the Wet Bulb Temperature calculation can be explained with given input values -> -243.158446 = 303.15-(0.021-0.016)*((0.01*2250000)/13.32).

FAQ

What is Wet Bulb Temperature?
The Wet Bulb Temperature formula is defined as the lowest temperature of air that is possible if water if added at constant pressure in air-water mixture and is represented as TW = TG-(YW'-YA)*((kY'*λW)/hG) or Wet Bulb Temperature = Temperature of Air-(Air Humidity at Wet Bulb Temperature-Ambient Air Humidity)*((Mass Transfer Coefficient of the Moisture*Heat of Vaporization at Wet Bulb Temperature)/Heat Transfer Coefficient of the Air Film). The Temperature of Air is defined as the temperature at which the air-water mixture properties in humidification are calculated, Air humidity at Wet Bulb Temperature refers to the moisture content present in the surrounding air at a given location at the Wet Bulb temperature, Ambient air humidity refers to the moisture content present in the surrounding air at a given location an temperature, Mass Transfer Coefficient of the Moisture is the proportionality factor between the mass transfer rate and the concentration driving force, The heat of vaporization at wet bulb temperature is the energy required per unit mass to convert liquid water into vapor at the wet bulb temperature of the gas liquid mixture & Heat Transfer Coefficient of the Air Film is the proportionality factor between the heat transfer rate and the temperature driving force.
How to calculate Wet Bulb Temperature?
The Wet Bulb Temperature formula is defined as the lowest temperature of air that is possible if water if added at constant pressure in air-water mixture is calculated using Wet Bulb Temperature = Temperature of Air-(Air Humidity at Wet Bulb Temperature-Ambient Air Humidity)*((Mass Transfer Coefficient of the Moisture*Heat of Vaporization at Wet Bulb Temperature)/Heat Transfer Coefficient of the Air Film). To calculate Wet Bulb Temperature, you need Temperature of Air (TG), Air Humidity at Wet Bulb Temperature (YW'), Ambient Air Humidity (YA), Mass Transfer Coefficient of the Moisture (kY'), Heat of Vaporization at Wet Bulb Temperature W) & Heat Transfer Coefficient of the Air Film (hG). With our tool, you need to enter the respective value for Temperature of Air, Air Humidity at Wet Bulb Temperature, Ambient Air Humidity, Mass Transfer Coefficient of the Moisture, Heat of Vaporization at Wet Bulb Temperature & Heat Transfer Coefficient of the Air Film and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!