Well Parameter Solution

STEP 0: Pre-Calculation Summary
Formula Used
Well Parameter = (Distance from Pumping Well^2*Storage Coefficient)/(4*Transmissivity*Time Period)
u = (r^2*S)/(4*T*t)
This formula uses 5 Variables
Variables Used
Well Parameter - Well Parameter is the characteristics and property that govern how water levels in a well change over time when water is being pumped.
Distance from Pumping Well - (Measured in Meter) - Distance from Pumping Well is the horizontal distance between a specific point in an aquifer and the location of a pumping well. It influences the behavior of groundwater flow.
Storage Coefficient - Storage Coefficient is the volume of water released from storage per unit decline in hydraulic head in the aquifer, per unit area of the aquifer.
Transmissivity - (Measured in Square Meter per Second) - Transmissivity is the rate at which groundwater flows horizontally through an aquifer or the degree to which a medium allows something, in particular electromagnetic radiation, to pass through it.
Time Period - (Measured in Second) - Time Period is the duration over which groundwater observations, measurements, or modeling simulations are conducted. It can vary from short-term periods to long-term periods.
STEP 1: Convert Input(s) to Base Unit
Distance from Pumping Well: 3 Meter --> 3 Meter No Conversion Required
Storage Coefficient: 85 --> No Conversion Required
Transmissivity: 11 Square Meter per Second --> 11 Square Meter per Second No Conversion Required
Time Period: 130 Second --> 130 Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
u = (r^2*S)/(4*T*t) --> (3^2*85)/(4*11*130)
Evaluating ... ...
u = 0.133741258741259
STEP 3: Convert Result to Output's Unit
0.133741258741259 --> No Conversion Required
FINAL ANSWER
0.133741258741259 0.133741 <-- Well Parameter
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has created this Calculator and 2000+ more calculators!
Verifier Image
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

Unsteady Flow in a Confined Aquifer Calculators

Drawdown
​ LaTeX ​ Go Total Drawdown = (Discharge/(4*pi*Transmissivity))*ln((2.2*Transmissivity*Time Period)/(Distance from Pumping Well^2*Storage Coefficient))
Drawdown at Time Interval 't1'
​ LaTeX ​ Go Drawdown at Time Interval t1 = Drawdown at Time Interval t2-((Discharge/(4*pi*Transmissivity))*ln(Time of Drawdown (t2)/Time of Drawdown (t1)))
Drawdown at Time Interval 't2'
​ LaTeX ​ Go Drawdown at Time Interval t2 = ((Discharge/(4*pi*Transmissivity))*ln(Time of Drawdown (t2)/Time of Drawdown (t1)))+Drawdown at Time Interval t1
Equation for Storage Coefficient
​ LaTeX ​ Go Storage Coefficient = 2.25*Transmissivity*Starting Time/Distance from Pumping Well^2

Well Parameter Formula

​LaTeX ​Go
Well Parameter = (Distance from Pumping Well^2*Storage Coefficient)/(4*Transmissivity*Time Period)
u = (r^2*S)/(4*T*t)

What is Drawdown in Hydrology?

Drawdown is a change in groundwater level due to an applied stress, caused by events such as: Pumping from a well. Pumping from a neighboring well. Intensive water taking from local area. Seasonal declines as recharge rates lower.

How to Calculate Well Parameter?

Well Parameter calculator uses Well Parameter = (Distance from Pumping Well^2*Storage Coefficient)/(4*Transmissivity*Time Period) to calculate the Well Parameter, The Well Parameter formula is defined as an essential property of the well function represented by a number of series to significant digits, rarely exceeding 4. Well Parameter is denoted by u symbol.

How to calculate Well Parameter using this online calculator? To use this online calculator for Well Parameter, enter Distance from Pumping Well (r), Storage Coefficient (S), Transmissivity (T) & Time Period (t) and hit the calculate button. Here is how the Well Parameter calculation can be explained with given input values -> 0.133741 = (3^2*85)/(4*11*130).

FAQ

What is Well Parameter?
The Well Parameter formula is defined as an essential property of the well function represented by a number of series to significant digits, rarely exceeding 4 and is represented as u = (r^2*S)/(4*T*t) or Well Parameter = (Distance from Pumping Well^2*Storage Coefficient)/(4*Transmissivity*Time Period). Distance from Pumping Well is the horizontal distance between a specific point in an aquifer and the location of a pumping well. It influences the behavior of groundwater flow, Storage Coefficient is the volume of water released from storage per unit decline in hydraulic head in the aquifer, per unit area of the aquifer, Transmissivity is the rate at which groundwater flows horizontally through an aquifer or the degree to which a medium allows something, in particular electromagnetic radiation, to pass through it & Time Period is the duration over which groundwater observations, measurements, or modeling simulations are conducted. It can vary from short-term periods to long-term periods.
How to calculate Well Parameter?
The Well Parameter formula is defined as an essential property of the well function represented by a number of series to significant digits, rarely exceeding 4 is calculated using Well Parameter = (Distance from Pumping Well^2*Storage Coefficient)/(4*Transmissivity*Time Period). To calculate Well Parameter, you need Distance from Pumping Well (r), Storage Coefficient (S), Transmissivity (T) & Time Period (t). With our tool, you need to enter the respective value for Distance from Pumping Well, Storage Coefficient, Transmissivity & Time Period and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!