Water Permeability based on Initial flux Solution

STEP 0: Pre-Calculation Summary
Formula Used
Water Permeability Through Membrane = Volumetric Water Flux Through Membrane/(Applied Pressure Driving Force*(1-(([R]*Temperature*Molecular Weight)/(Initial Volume*Applied Pressure Driving Force))))
Lp = Jwv/(ΔPm*(1-(([R]*T*n0)/(V0*ΔPm))))
This formula uses 1 Constants, 6 Variables
Constants Used
[R] - Universal gas constant Value Taken As 8.31446261815324
Variables Used
Water Permeability Through Membrane - (Measured in Cubic Meter per Square Meter per Second per Pascal) - Water permeability through membrane is the ability of a material to allow water to pass through it. It is a measure of how easily water can flow through a material's pores.
Volumetric Water Flux Through Membrane - (Measured in Cubic Meter per Square Meter per Second) - Volumetric Water flux through membrane is the rate at which water flows through a given area of a material per unit of time.
Applied Pressure Driving Force - (Measured in Pascal) - Applied Pressure Driving Force is defined as the force or pressure that is intentionally exerted or applied to induce or facilitate process.
Temperature - (Measured in Kelvin) - Temperature is a physical quantity that expresses quantitatively the attribute of hotness or coldness.
Molecular Weight - (Measured in Kilogram Per Mole) - Molecular weight is the mass of a molecule, relative to the mass of a carbon-12 atom. It is also known as molecular mass.
Initial Volume - (Measured in Cubic Meter) - Initial volume is the volume of a substance at a specific time or point in time. It is often used in fluid mechanics to describe the volume of a fluid at the beginning of a process or experiment.
STEP 1: Convert Input(s) to Base Unit
Volumetric Water Flux Through Membrane: 5.7E-07 Cubic Meter per Square Meter per Second --> 5.7E-07 Cubic Meter per Square Meter per Second No Conversion Required
Applied Pressure Driving Force: 300000 Pascal --> 300000 Pascal No Conversion Required
Temperature: 298 Kelvin --> 298 Kelvin No Conversion Required
Molecular Weight: 0.01802 Kilogram Per Mole --> 0.01802 Kilogram Per Mole No Conversion Required
Initial Volume: 0.000148829 Cubic Meter --> 0.000148829 Cubic Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Lp = Jwv/(ΔPm*(1-(([R]*T*n0)/(V0*ΔPm)))) --> 5.7E-07/(300000*(1-(([R]*298*0.01802)/(0.000148829*300000))))
Evaluating ... ...
Lp = 2.30323510248994E-07
STEP 3: Convert Result to Output's Unit
2.30323510248994E-07 Cubic Meter per Square Meter per Second per Pascal --> No Conversion Required
FINAL ANSWER
2.30323510248994E-07 2.3E-7 Cubic Meter per Square Meter per Second per Pascal <-- Water Permeability Through Membrane
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Harsh Kadam
Shri Guru Gobind Singhji Institute of Engineering and Technology (SGGS), Nanded
Harsh Kadam has created this Calculator and 50+ more calculators!
Verifier Image
Verified by Vaibhav Mishra
DJ Sanghvi College of Engineering (DJSCE), Mumbai
Vaibhav Mishra has verified this Calculator and 200+ more calculators!

Basics of Membrane Separation Processes Calculators

Hagen Poiseuille Based Flux for Membrane Separation
​ LaTeX ​ Go Flux through Membrane = (Membrane Porosity*Pore Diameter^2*Applied Pressure Driving Force)/(32*Liquid Viscosity*Tortuosity*Membrane Thickness)
Liquid Viscosity based on Membrane Resistance
​ LaTeX ​ Go Liquid Viscosity = Applied Pressure Driving Force/(Membrane Flow Resistance of Unit Area*Flux through Membrane)
Membrane Flux Based on Resistance
​ LaTeX ​ Go Flux through Membrane = Applied Pressure Driving Force/(Membrane Flow Resistance of Unit Area*Liquid Viscosity)
Resistance to flow in Membranes
​ LaTeX ​ Go Membrane Flow Resistance of Unit Area = Applied Pressure Driving Force/(Liquid Viscosity*Flux through Membrane)

Water Permeability based on Initial flux Formula

​LaTeX ​Go
Water Permeability Through Membrane = Volumetric Water Flux Through Membrane/(Applied Pressure Driving Force*(1-(([R]*Temperature*Molecular Weight)/(Initial Volume*Applied Pressure Driving Force))))
Lp = Jwv/(ΔPm*(1-(([R]*T*n0)/(V0*ΔPm))))

On What Factors Does the Water Permeability Depended?

Water permeability depends on a number of factors, including
Pore size and distribution
Tortuosity of the pores
Temperature
Viscosity
pH
Pressure gradient



How to Calculate Water Permeability based on Initial flux?

Water Permeability based on Initial flux calculator uses Water Permeability Through Membrane = Volumetric Water Flux Through Membrane/(Applied Pressure Driving Force*(1-(([R]*Temperature*Molecular Weight)/(Initial Volume*Applied Pressure Driving Force)))) to calculate the Water Permeability Through Membrane, Water permeability based on Initial flux is defined as the measure of how easily water can flow through a porous material based on the Initial flux of the Membrane. Water Permeability Through Membrane is denoted by Lp symbol.

How to calculate Water Permeability based on Initial flux using this online calculator? To use this online calculator for Water Permeability based on Initial flux, enter Volumetric Water Flux Through Membrane (Jwv), Applied Pressure Driving Force (ΔPm), Temperature (T), Molecular Weight (n0) & Initial Volume (V0) and hit the calculate button. Here is how the Water Permeability based on Initial flux calculation can be explained with given input values -> 1.9E-7 = 5.7E-07/(300000*(1-(([R]*298*0.01802)/(0.000148829*300000)))).

FAQ

What is Water Permeability based on Initial flux?
Water permeability based on Initial flux is defined as the measure of how easily water can flow through a porous material based on the Initial flux of the Membrane and is represented as Lp = Jwv/(ΔPm*(1-(([R]*T*n0)/(V0*ΔPm)))) or Water Permeability Through Membrane = Volumetric Water Flux Through Membrane/(Applied Pressure Driving Force*(1-(([R]*Temperature*Molecular Weight)/(Initial Volume*Applied Pressure Driving Force)))). Volumetric Water flux through membrane is the rate at which water flows through a given area of a material per unit of time, Applied Pressure Driving Force is defined as the force or pressure that is intentionally exerted or applied to induce or facilitate process, Temperature is a physical quantity that expresses quantitatively the attribute of hotness or coldness, Molecular weight is the mass of a molecule, relative to the mass of a carbon-12 atom. It is also known as molecular mass & Initial volume is the volume of a substance at a specific time or point in time. It is often used in fluid mechanics to describe the volume of a fluid at the beginning of a process or experiment.
How to calculate Water Permeability based on Initial flux?
Water permeability based on Initial flux is defined as the measure of how easily water can flow through a porous material based on the Initial flux of the Membrane is calculated using Water Permeability Through Membrane = Volumetric Water Flux Through Membrane/(Applied Pressure Driving Force*(1-(([R]*Temperature*Molecular Weight)/(Initial Volume*Applied Pressure Driving Force)))). To calculate Water Permeability based on Initial flux, you need Volumetric Water Flux Through Membrane (Jwv), Applied Pressure Driving Force (ΔPm), Temperature (T), Molecular Weight (n0) & Initial Volume (V0). With our tool, you need to enter the respective value for Volumetric Water Flux Through Membrane, Applied Pressure Driving Force, Temperature, Molecular Weight & Initial Volume and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Water Permeability Through Membrane?
In this formula, Water Permeability Through Membrane uses Volumetric Water Flux Through Membrane, Applied Pressure Driving Force, Temperature, Molecular Weight & Initial Volume. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Water Permeability Through Membrane = Flux through Membrane/Applied Pressure Driving Force
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!