Wastewater Flow given Hydraulic Loading Solution

STEP 0: Pre-Calculation Summary
Formula Used
Waste Water Flow = Hydraulic Loading*Area*1440/(1+Recirculation Ratio)
Ww = H*A*1440/(1+α)
This formula uses 4 Variables
Variables Used
Waste Water Flow - (Measured in Cubic Meter per Second) - Waste Water Flow refers to the movement of water and dissolved waste materials from residential, commercial, industrial, agricultural sources through a sewer system to a treatment facility.
Hydraulic Loading - (Measured in Cubic Meter per Second) - Hydraulic Loading refers to the volume of liquid (feedstock) that is added to the digester per unit of time and surface area.
Area - (Measured in Square Meter) - The Area is the amount of two-dimensional space taken up by an object.
Recirculation Ratio - Recirculation Ratio is the ratio of the RAS pumping rate to influent flow rate.
STEP 1: Convert Input(s) to Base Unit
Hydraulic Loading: 4 Cubic Meter per Day --> 4.62962962962963E-05 Cubic Meter per Second (Check conversion ​here)
Area: 50 Square Meter --> 50 Square Meter No Conversion Required
Recirculation Ratio: 1.5 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Ww = H*A*1440/(1+α) --> 4.62962962962963E-05*50*1440/(1+1.5)
Evaluating ... ...
Ww = 1.33333333333333
STEP 3: Convert Result to Output's Unit
1.33333333333333 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
1.33333333333333 1.333333 Cubic Meter per Second <-- Waste Water Flow
(Calculation completed in 00.008 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 500+ more calculators!

Wastewater Flow Calculators

Wastewater Flow given Hydraulic Loading
​ LaTeX ​ Go Waste Water Flow = Hydraulic Loading*Area*1440/(1+Recirculation Ratio)
Wastewater Flow given BOD Loading for First Stage
​ LaTeX ​ Go Waste Water Flow = BOD Loading to Filter 2/(8.34*Influent BOD)
Wastewater Flow given Recirculation Ratio
​ LaTeX ​ Go Waste Water Flow = Recirculation Flow/Recirculation Ratio

Wastewater Flow given Hydraulic Loading Formula

​LaTeX ​Go
Waste Water Flow = Hydraulic Loading*Area*1440/(1+Recirculation Ratio)
Ww = H*A*1440/(1+α)

What is Hydraulic Loading?

Hydraulic Loading is defined as wastewater treatment process unit as the volume of wastewater applied to the surface of the process unit per time period. It is often expressed in gallons per day per square foot (gpd/ft2).

How to Calculate Wastewater Flow given Hydraulic Loading?

Wastewater Flow given Hydraulic Loading calculator uses Waste Water Flow = Hydraulic Loading*Area*1440/(1+Recirculation Ratio) to calculate the Waste Water Flow, The Wastewater Flow given Hydraulic Loading formula is defined as the hydraulic load on the treatment plant. It affects the design, operation, and efficiency of treatment processes. Waste Water Flow is denoted by Ww symbol.

How to calculate Wastewater Flow given Hydraulic Loading using this online calculator? To use this online calculator for Wastewater Flow given Hydraulic Loading, enter Hydraulic Loading (H), Area (A) & Recirculation Ratio (α) and hit the calculate button. Here is how the Wastewater Flow given Hydraulic Loading calculation can be explained with given input values -> 1.333333 = 4.62962962962963E-05*50*1440/(1+1.5).

FAQ

What is Wastewater Flow given Hydraulic Loading?
The Wastewater Flow given Hydraulic Loading formula is defined as the hydraulic load on the treatment plant. It affects the design, operation, and efficiency of treatment processes and is represented as Ww = H*A*1440/(1+α) or Waste Water Flow = Hydraulic Loading*Area*1440/(1+Recirculation Ratio). Hydraulic Loading refers to the volume of liquid (feedstock) that is added to the digester per unit of time and surface area, The Area is the amount of two-dimensional space taken up by an object & Recirculation Ratio is the ratio of the RAS pumping rate to influent flow rate.
How to calculate Wastewater Flow given Hydraulic Loading?
The Wastewater Flow given Hydraulic Loading formula is defined as the hydraulic load on the treatment plant. It affects the design, operation, and efficiency of treatment processes is calculated using Waste Water Flow = Hydraulic Loading*Area*1440/(1+Recirculation Ratio). To calculate Wastewater Flow given Hydraulic Loading, you need Hydraulic Loading (H), Area (A) & Recirculation Ratio (α). With our tool, you need to enter the respective value for Hydraulic Loading, Area & Recirculation Ratio and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Waste Water Flow?
In this formula, Waste Water Flow uses Hydraulic Loading, Area & Recirculation Ratio. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Waste Water Flow = Recirculation Flow/Recirculation Ratio
  • Waste Water Flow = BOD Loading to Filter 2/(8.34*Influent BOD)