WAS Pumping Rate from Aeration Tank Solution

STEP 0: Pre-Calculation Summary
Formula Used
WAS Pumping Rate from Reactor = Reactor Volume/Mean Cell Residence Time
Qw = V/θc
This formula uses 3 Variables
Variables Used
WAS Pumping Rate from Reactor - (Measured in Cubic Meter per Second) - WAS Pumping Rate from Reactor is the total amount of waste activated sludge that comes out from the reactor.
Reactor Volume - (Measured in Cubic Meter) - Reactor Volume refers to the physical volume of a reactor used in chemical processes.
Mean Cell Residence Time - (Measured in Second) - Mean Cell Residence Time is the average time that the sludge remains in the reactor.
STEP 1: Convert Input(s) to Base Unit
Reactor Volume: 1000 Cubic Meter --> 1000 Cubic Meter No Conversion Required
Mean Cell Residence Time: 7 Day --> 604800 Second (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Qw = V/θc --> 1000/604800
Evaluating ... ...
Qw = 0.00165343915343915
STEP 3: Convert Result to Output's Unit
0.00165343915343915 Cubic Meter per Second -->142.857142857143 Cubic Meter per Day (Check conversion ​here)
FINAL ANSWER
142.857142857143 142.8571 Cubic Meter per Day <-- WAS Pumping Rate from Reactor
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

WAS Pumping Rate Calculators

WAS Pumping Rate from Return Line given Wasting Rate from Return Line
​ LaTeX ​ Go WAS Pumping Rate from Reactor = (Reactor Volume*MLSS/(Mean Cell Residence Time*Sludge Concentration in Return Line))-(Effluent Flow Rate*Solid Concentration in Effluent/Sludge Concentration in Return Line)
WAS Pumping Rate from Return Line given RAS Pumping Rate from Aeration Tank
​ LaTeX ​ Go WAS Pumping Rate from Reactor = ((MLSS/Sludge Concentration in Return Line)*(Average Daily Influent Flow Rate+Return Activated Sludge))-Return Activated Sludge
WAS Pumping Rate using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low
​ LaTeX ​ Go WAS Pumping Rate from Reactor = Reactor Volume*MLSS/(Mean Cell Residence Time*Sludge Concentration in Return Line)
WAS Pumping Rate from Aeration Tank
​ LaTeX ​ Go WAS Pumping Rate from Reactor = Reactor Volume/Mean Cell Residence Time

WAS Pumping Rate from Aeration Tank Formula

​LaTeX ​Go
WAS Pumping Rate from Reactor = Reactor Volume/Mean Cell Residence Time
Qw = V/θc

What is Aeration Tank?

An Aeration Tank is a critical component in wastewater treatment plants, particularly in the activated sludge process. It is a large, often rectangular or circular, tank where wastewater is mixed with air (or oxygen) to support the growth of aerobic microorganisms. These microorganisms break down organic matter in the wastewater through biological processes.

How to Calculate WAS Pumping Rate from Aeration Tank?

WAS Pumping Rate from Aeration Tank calculator uses WAS Pumping Rate from Reactor = Reactor Volume/Mean Cell Residence Time to calculate the WAS Pumping Rate from Reactor, The WAS Pumping Rate from Aeration Tank formula is defined as the total amount of waste-activated sludge that comes out from the reactor. WAS Pumping Rate from Reactor is denoted by Qw symbol.

How to calculate WAS Pumping Rate from Aeration Tank using this online calculator? To use this online calculator for WAS Pumping Rate from Aeration Tank, enter Reactor Volume (V) & Mean Cell Residence Time c) and hit the calculate button. Here is how the WAS Pumping Rate from Aeration Tank calculation can be explained with given input values -> 1.2E+7 = 1000/604800.

FAQ

What is WAS Pumping Rate from Aeration Tank?
The WAS Pumping Rate from Aeration Tank formula is defined as the total amount of waste-activated sludge that comes out from the reactor and is represented as Qw = V/θc or WAS Pumping Rate from Reactor = Reactor Volume/Mean Cell Residence Time. Reactor Volume refers to the physical volume of a reactor used in chemical processes & Mean Cell Residence Time is the average time that the sludge remains in the reactor.
How to calculate WAS Pumping Rate from Aeration Tank?
The WAS Pumping Rate from Aeration Tank formula is defined as the total amount of waste-activated sludge that comes out from the reactor is calculated using WAS Pumping Rate from Reactor = Reactor Volume/Mean Cell Residence Time. To calculate WAS Pumping Rate from Aeration Tank, you need Reactor Volume (V) & Mean Cell Residence Time c). With our tool, you need to enter the respective value for Reactor Volume & Mean Cell Residence Time and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate WAS Pumping Rate from Reactor?
In this formula, WAS Pumping Rate from Reactor uses Reactor Volume & Mean Cell Residence Time. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • WAS Pumping Rate from Reactor = (Reactor Volume*MLSS/(Mean Cell Residence Time*Sludge Concentration in Return Line))-(Effluent Flow Rate*Solid Concentration in Effluent/Sludge Concentration in Return Line)
  • WAS Pumping Rate from Reactor = Reactor Volume*MLSS/(Mean Cell Residence Time*Sludge Concentration in Return Line)
  • WAS Pumping Rate from Reactor = ((MLSS/Sludge Concentration in Return Line)*(Average Daily Influent Flow Rate+Return Activated Sludge))-Return Activated Sludge
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!