Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester Solution

STEP 0: Pre-Calculation Summary
Formula Used
Volumetric Flow Rate = (BOD per Day/Volumetric Loading)
V = (BODday/Vl)
This formula uses 3 Variables
Variables Used
Volumetric Flow Rate - (Measured in Cubic Meter per Second) - Volumetric Flow Rate is referred as measure of the volume of fluid that flows through a given surface per unit time.
BOD per Day - (Measured in Kilogram per Second) - BOD per Day is defined as biological oxygen demand in terms of mass flow rate.
Volumetric Loading - (Measured in Kilogram per Cubic Meter) - Volumetric Loading is referred as the amount of wastewater or sludge applied to a treatment unit per unit volume of the unit per unit time.
STEP 1: Convert Input(s) to Base Unit
BOD per Day: 10 Kilogram per Day --> 0.000115740740740741 Kilogram per Second (Check conversion ​here)
Volumetric Loading: 2.4E-05 Kilogram per Cubic Meter --> 2.4E-05 Kilogram per Cubic Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
V = (BODday/Vl) --> (0.000115740740740741/2.4E-05)
Evaluating ... ...
V = 4.82253086419754
STEP 3: Convert Result to Output's Unit
4.82253086419754 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
4.82253086419754 4.822531 Cubic Meter per Second <-- Volumetric Flow Rate
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Design of an Anaerobic Digester Calculators

Influent Sludge Flow Rate given Volume Required for Anaerobic Digester
​ LaTeX ​ Go Influent Sludge Flow Rate = (Volume/Hydraulic Retention Time)
Volume Required for Anaerobic Digester
​ LaTeX ​ Go Volume = (Hydraulic Retention Time*Influent Sludge Flow Rate)
Hydraulic Retention Time given Volume Required for Anaerobic Digester
​ LaTeX ​ Go Hydraulic Retention = (Volume/Influent Sludge Flow Rate)
Volumetric Loading in Anaerobic Digester
​ LaTeX ​ Go Volumetric Loading = (BOD per Day/Volumetric Flow Rate)

Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester Formula

​LaTeX ​Go
Volumetric Flow Rate = (BOD per Day/Volumetric Loading)
V = (BODday/Vl)

What is Volumetric Flow Rate?

The Volumetric Flow Rate (also known as volume flow rate, rate of fluid flow, or volume velocity) is the volume of fluid which passes per unit time; usually it is represented by the symbol Q (sometimes V̇). The SI unit is cubic metres per second (m3/s).

How to Calculate Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester?

Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester calculator uses Volumetric Flow Rate = (BOD per Day/Volumetric Loading) to calculate the Volumetric Flow Rate, The Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester formula is defined as the the volume of liquid (feedstock) entering the digester per unit time. It is typically measured in cubic meters per day (m³/day). Volumetric Flow Rate is denoted by V symbol.

How to calculate Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester using this online calculator? To use this online calculator for Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester, enter BOD per Day (BODday) & Volumetric Loading (Vl) and hit the calculate button. Here is how the Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester calculation can be explained with given input values -> 4.822531 = (0.000115740740740741/2.4E-05).

FAQ

What is Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester?
The Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester formula is defined as the the volume of liquid (feedstock) entering the digester per unit time. It is typically measured in cubic meters per day (m³/day) and is represented as V = (BODday/Vl) or Volumetric Flow Rate = (BOD per Day/Volumetric Loading). BOD per Day is defined as biological oxygen demand in terms of mass flow rate & Volumetric Loading is referred as the amount of wastewater or sludge applied to a treatment unit per unit volume of the unit per unit time.
How to calculate Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester?
The Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester formula is defined as the the volume of liquid (feedstock) entering the digester per unit time. It is typically measured in cubic meters per day (m³/day) is calculated using Volumetric Flow Rate = (BOD per Day/Volumetric Loading). To calculate Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester, you need BOD per Day (BODday) & Volumetric Loading (Vl). With our tool, you need to enter the respective value for BOD per Day & Volumetric Loading and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!