Volume Required for Anaerobic Digester Solution

STEP 0: Pre-Calculation Summary
Formula Used
Volume = (Hydraulic Retention Time*Influent Sludge Flow Rate)
VT = (θ*Qs)
This formula uses 3 Variables
Variables Used
Volume - (Measured in Cubic Meter) - Volume refers to the amount of space that a substance or object occupies or that is enclosed within a container.
Hydraulic Retention Time - (Measured in Second) - Hydraulic Retention Time referred as the ratio between the reactor volume and the feed flow rate, represents the average time the cells and substrates stay inside the reactor.
Influent Sludge Flow Rate - (Measured in Cubic Meter per Second) - Influent Sludge Flow Rate is defined as discharge of sludge.
STEP 1: Convert Input(s) to Base Unit
Hydraulic Retention Time: 4 Hour --> 14400 Second (Check conversion ​here)
Influent Sludge Flow Rate: 2 Cubic Meter per Second --> 2 Cubic Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
VT = (θ*Qs) --> (14400*2)
Evaluating ... ...
VT = 28800
STEP 3: Convert Result to Output's Unit
28800 Cubic Meter --> No Conversion Required
FINAL ANSWER
28800 Cubic Meter <-- Volume
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Design of an Anaerobic Digester Calculators

Influent Sludge Flow Rate given Volume Required for Anaerobic Digester
​ LaTeX ​ Go Influent Sludge Flow Rate = (Volume/Hydraulic Retention Time)
Volume Required for Anaerobic Digester
​ LaTeX ​ Go Volume = (Hydraulic Retention Time*Influent Sludge Flow Rate)
Hydraulic Retention Time given Volume Required for Anaerobic Digester
​ LaTeX ​ Go Hydraulic Retention = (Volume/Influent Sludge Flow Rate)
Volumetric Loading in Anaerobic Digester
​ LaTeX ​ Go Volumetric Loading = (BOD per Day/Volumetric Flow Rate)

Volume Required for Anaerobic Digester Formula

​LaTeX ​Go
Volume = (Hydraulic Retention Time*Influent Sludge Flow Rate)
VT = (θ*Qs)

What is Hydraulic Retention Time?

Hydraulic Retention Time (HRT) is a measure of the average length of time that a soluble compound remains in a constructed bioreactor. The volume of the aeration tank divided by the influent flow rate is τ (tau), the hydraulic retention time.

How to Calculate Volume Required for Anaerobic Digester?

Volume Required for Anaerobic Digester calculator uses Volume = (Hydraulic Retention Time*Influent Sludge Flow Rate) to calculate the Volume, The Volume Required for Anaerobic Digester formula is defined as the total space needed within the digester to efficiently process the input feedstock under anaerobic conditions, allowing for the production of biogas (mainly methane) and the stabilization of the organic material. This volume ensures that the feedstock remains in the digester for a sufficient period, providing the necessary conditions for microorganisms to break down the organic matter. Volume is denoted by VT symbol.

How to calculate Volume Required for Anaerobic Digester using this online calculator? To use this online calculator for Volume Required for Anaerobic Digester, enter Hydraulic Retention Time (θ) & Influent Sludge Flow Rate (Qs) and hit the calculate button. Here is how the Volume Required for Anaerobic Digester calculation can be explained with given input values -> 28800 = (14400*2).

FAQ

What is Volume Required for Anaerobic Digester?
The Volume Required for Anaerobic Digester formula is defined as the total space needed within the digester to efficiently process the input feedstock under anaerobic conditions, allowing for the production of biogas (mainly methane) and the stabilization of the organic material. This volume ensures that the feedstock remains in the digester for a sufficient period, providing the necessary conditions for microorganisms to break down the organic matter and is represented as VT = (θ*Qs) or Volume = (Hydraulic Retention Time*Influent Sludge Flow Rate). Hydraulic Retention Time referred as the ratio between the reactor volume and the feed flow rate, represents the average time the cells and substrates stay inside the reactor & Influent Sludge Flow Rate is defined as discharge of sludge.
How to calculate Volume Required for Anaerobic Digester?
The Volume Required for Anaerobic Digester formula is defined as the total space needed within the digester to efficiently process the input feedstock under anaerobic conditions, allowing for the production of biogas (mainly methane) and the stabilization of the organic material. This volume ensures that the feedstock remains in the digester for a sufficient period, providing the necessary conditions for microorganisms to break down the organic matter is calculated using Volume = (Hydraulic Retention Time*Influent Sludge Flow Rate). To calculate Volume Required for Anaerobic Digester, you need Hydraulic Retention Time (θ) & Influent Sludge Flow Rate (Qs). With our tool, you need to enter the respective value for Hydraulic Retention Time & Influent Sludge Flow Rate and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!