Volume of Tank given Microbial Mass in Aeration System Solution

STEP 0: Pre-Calculation Summary
Formula Used
Volume of Tank = Total Microbial Mass/MLSS
V = Mt/X
This formula uses 3 Variables
Variables Used
Volume of Tank - (Measured in Cubic Meter) - Volume of Tank is defined as the capacity of flocculation and mixing tank.
Total Microbial Mass - (Measured in Kilogram) - Total Microbial Mass is the cumulative mass of microorganisms present in a given sample or system. This includes bacteria, fungi, protozoa, and other microbes.
MLSS - (Measured in Kilogram per Cubic Meter) - MLSS is the concentration of suspended solids in the mixed liquor within an aeration tank during the activated sludge process.
STEP 1: Convert Input(s) to Base Unit
Total Microbial Mass: 3 Gram --> 0.003 Kilogram (Check conversion ​here)
MLSS: 2 Milligram per Liter --> 0.002 Kilogram per Cubic Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
V = Mt/X --> 0.003/0.002
Evaluating ... ...
V = 1.5
STEP 3: Convert Result to Output's Unit
1.5 Cubic Meter --> No Conversion Required
FINAL ANSWER
1.5 Cubic Meter <-- Volume of Tank
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Food is to Microorganism Ratio or F is to M Ratio Calculators

BOD Load applied to Aeration System
​ LaTeX ​ Go BOD Load applied to Aeration System = Sewage Flow*Influent BOD
Total Microbial Mass given Food to Microorganism Ratio
​ LaTeX ​ Go Total Microbial Mass = Daily BOD/Food to Microorganism Ratio
Daily BOD Load given Food to Microorganism Ratio
​ LaTeX ​ Go Daily BOD = Food to Microorganism Ratio*Total Microbial Mass
Food to Microorganism Ratio
​ LaTeX ​ Go Food to Microorganism Ratio = Daily BOD/Total Microbial Mass

Volume of Tank given Microbial Mass in Aeration System Formula

​LaTeX ​Go
Volume of Tank = Total Microbial Mass/MLSS
V = Mt/X

What is MLSS?

Mixed liquor suspended solids (MLSS) is the concentration of suspended solids, in an aeration tank during the activated sludge process, which occurs during the treatment of waste water.

How to Calculate Volume of Tank given Microbial Mass in Aeration System?

Volume of Tank given Microbial Mass in Aeration System calculator uses Volume of Tank = Total Microbial Mass/MLSS to calculate the Volume of Tank, The Volume of Tank given Microbial Mass in Aeration System formula is defined as the calculation of the volume of a biological treatment tank, such as an aeration tank in a wastewater treatment plant, based on the microbial mass in aeration tank. Volume of Tank is denoted by V symbol.

How to calculate Volume of Tank given Microbial Mass in Aeration System using this online calculator? To use this online calculator for Volume of Tank given Microbial Mass in Aeration System, enter Total Microbial Mass (Mt) & MLSS (X) and hit the calculate button. Here is how the Volume of Tank given Microbial Mass in Aeration System calculation can be explained with given input values -> 1.5 = 0.003/0.002.

FAQ

What is Volume of Tank given Microbial Mass in Aeration System?
The Volume of Tank given Microbial Mass in Aeration System formula is defined as the calculation of the volume of a biological treatment tank, such as an aeration tank in a wastewater treatment plant, based on the microbial mass in aeration tank and is represented as V = Mt/X or Volume of Tank = Total Microbial Mass/MLSS. Total Microbial Mass is the cumulative mass of microorganisms present in a given sample or system. This includes bacteria, fungi, protozoa, and other microbes & MLSS is the concentration of suspended solids in the mixed liquor within an aeration tank during the activated sludge process.
How to calculate Volume of Tank given Microbial Mass in Aeration System?
The Volume of Tank given Microbial Mass in Aeration System formula is defined as the calculation of the volume of a biological treatment tank, such as an aeration tank in a wastewater treatment plant, based on the microbial mass in aeration tank is calculated using Volume of Tank = Total Microbial Mass/MLSS. To calculate Volume of Tank given Microbial Mass in Aeration System, you need Total Microbial Mass (Mt) & MLSS (X). With our tool, you need to enter the respective value for Total Microbial Mass & MLSS and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Volume of Tank?
In this formula, Volume of Tank uses Total Microbial Mass & MLSS. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Volume of Tank = (Sewage Flow*Influent BOD)/(Food to Microorganism Ratio*MLSS)
  • Volume of Tank = (Total Microbial Mass*Sewage Flow*Influent BOD)/(MLSS*Daily BOD)