Volume of Tank given Food to Microorganism Ratio Solution

STEP 0: Pre-Calculation Summary
Formula Used
Volume of Tank = (Sewage Flow*Influent BOD)/(Food to Microorganism Ratio*MLSS)
V = (Q*Qi)/(FM*X)
This formula uses 5 Variables
Variables Used
Volume of Tank - (Measured in Cubic Meter) - Volume of Tank is defined as the capacity of flocculation and mixing tank.
Sewage Flow - (Measured in Cubic Meter) - Sewage Flow into the aeration tank is the sewage flow into the aeration tank when we have prior information of other parameters used.
Influent BOD - (Measured in Kilogram per Cubic Meter) - Influent BOD is the total amount of BOD which is present in the incoming sewage.
Food to Microorganism Ratio - Food to Microorganism Ratio is actually a measurement of the amount of incoming food divided by the Lbs of Microorganisms in your system.
MLSS - (Measured in Kilogram per Cubic Meter) - MLSS is the concentration of suspended solids in the mixed liquor within an aeration tank during the activated sludge process.
STEP 1: Convert Input(s) to Base Unit
Sewage Flow: 3.33 Cubic Meter --> 3.33 Cubic Meter No Conversion Required
Influent BOD: 0.0009 Milligram per Liter --> 9E-07 Kilogram per Cubic Meter (Check conversion ​here)
Food to Microorganism Ratio: 0.001 --> No Conversion Required
MLSS: 2 Milligram per Liter --> 0.002 Kilogram per Cubic Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
V = (Q*Qi)/(FM*X) --> (3.33*9E-07)/(0.001*0.002)
Evaluating ... ...
V = 1.4985
STEP 3: Convert Result to Output's Unit
1.4985 Cubic Meter --> No Conversion Required
FINAL ANSWER
1.4985 Cubic Meter <-- Volume of Tank
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Food to Microorganism Ratio or F to M Ratio Calculators

BOD Load applied to Aeration System
​ Go BOD Load applied to Aeration System = Sewage Flow*Influent BOD
Total Microbial Mass given Food to Microorganism Ratio
​ Go Total Microbial Mass = Daily BOD/Food to Microorganism Ratio
Daily BOD Load given Food to Microorganism Ratio
​ Go Daily BOD = Food to Microorganism Ratio*Total Microbial Mass
Food to Microorganism Ratio
​ Go Food to Microorganism Ratio = Daily BOD/Total Microbial Mass

Volume of Tank given Food to Microorganism Ratio Formula

Volume of Tank = (Sewage Flow*Influent BOD)/(Food to Microorganism Ratio*MLSS)
V = (Q*Qi)/(FM*X)

What is Food to Microorganism Ratio ?

The term Food to Microorganism Ratio (F/M) is actually a measurement of the amount of incoming food ( Lbs of Influent BOD) divided by the Lbs of Microorganisms in your system.

How to Calculate Volume of Tank given Food to Microorganism Ratio?

Volume of Tank given Food to Microorganism Ratio calculator uses Volume of Tank = (Sewage Flow*Influent BOD)/(Food to Microorganism Ratio*MLSS) to calculate the Volume of Tank, The Volume of Tank given Food to Microorganism Ratio formula is defined as the calculation of the volume of a biological treatment tank, such as an aeration tank in a wastewater treatment plant, based on the ratio of the organic load (food) to the concentration of microorganisms (biomass) present in the system. Volume of Tank is denoted by V symbol.

How to calculate Volume of Tank given Food to Microorganism Ratio using this online calculator? To use this online calculator for Volume of Tank given Food to Microorganism Ratio, enter Sewage Flow (Q), Influent BOD (Qi), Food to Microorganism Ratio (FM) & MLSS (X) and hit the calculate button. Here is how the Volume of Tank given Food to Microorganism Ratio calculation can be explained with given input values -> 1.4985 = (3.33*9E-07)/(0.001*0.002).

FAQ

What is Volume of Tank given Food to Microorganism Ratio?
The Volume of Tank given Food to Microorganism Ratio formula is defined as the calculation of the volume of a biological treatment tank, such as an aeration tank in a wastewater treatment plant, based on the ratio of the organic load (food) to the concentration of microorganisms (biomass) present in the system and is represented as V = (Q*Qi)/(FM*X) or Volume of Tank = (Sewage Flow*Influent BOD)/(Food to Microorganism Ratio*MLSS). Sewage Flow into the aeration tank is the sewage flow into the aeration tank when we have prior information of other parameters used, Influent BOD is the total amount of BOD which is present in the incoming sewage, Food to Microorganism Ratio is actually a measurement of the amount of incoming food divided by the Lbs of Microorganisms in your system & MLSS is the concentration of suspended solids in the mixed liquor within an aeration tank during the activated sludge process.
How to calculate Volume of Tank given Food to Microorganism Ratio?
The Volume of Tank given Food to Microorganism Ratio formula is defined as the calculation of the volume of a biological treatment tank, such as an aeration tank in a wastewater treatment plant, based on the ratio of the organic load (food) to the concentration of microorganisms (biomass) present in the system is calculated using Volume of Tank = (Sewage Flow*Influent BOD)/(Food to Microorganism Ratio*MLSS). To calculate Volume of Tank given Food to Microorganism Ratio, you need Sewage Flow (Q), Influent BOD (Qi), Food to Microorganism Ratio (FM) & MLSS (X). With our tool, you need to enter the respective value for Sewage Flow, Influent BOD, Food to Microorganism Ratio & MLSS and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Volume of Tank?
In this formula, Volume of Tank uses Sewage Flow, Influent BOD, Food to Microorganism Ratio & MLSS. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Volume of Tank = Total Microbial Mass/MLSS
  • Volume of Tank = (Total Microbial Mass*Sewage Flow*Influent BOD)/(MLSS*Daily BOD)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!