Volume of liquid at outlet Solution

STEP 0: Pre-Calculation Summary
Formula Used
Actual Discharge at Centrifugal Pump Outlet = pi*Diameter of Centrifugal Pump Impeller at Outlet*Width of Impeller at Outlet*Flow Velocity at Outlet of Centrifugal Pump
Q = pi*D2*B2*Vf2
This formula uses 1 Constants, 4 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
Variables Used
Actual Discharge at Centrifugal Pump Outlet - (Measured in Cubic Meter per Second) - Actual discharge at centrifugal pump outlet is the actual amount of the liquid outflow from the outlet of the centrifugal pump.
Diameter of Centrifugal Pump Impeller at Outlet - (Measured in Meter) - Diameter of centrifugal pump impeller at outlet is the diameter of the impeller at the outlet of the centrifugal pump.
Width of Impeller at Outlet - (Measured in Meter) - The Width of Impeller at Outlet is the width of the impeller at the outlet of the pump.
Flow Velocity at Outlet of Centrifugal Pump - (Measured in Meter per Second) - Flow velocity at outlet of centrifugal pump is the velocity of the fluid at the outlet of the impeller or the centrifugal pump.
STEP 1: Convert Input(s) to Base Unit
Diameter of Centrifugal Pump Impeller at Outlet: 0.28 Meter --> 0.28 Meter No Conversion Required
Width of Impeller at Outlet: 0.03 Meter --> 0.03 Meter No Conversion Required
Flow Velocity at Outlet of Centrifugal Pump: 2.12 Meter per Second --> 2.12 Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Q = pi*D2*B2*Vf2 --> pi*0.28*0.03*2.12
Evaluating ... ...
Q = 0.055945481975127
STEP 3: Convert Result to Output's Unit
0.055945481975127 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
0.055945481975127 0.055945 Cubic Meter per Second <-- Actual Discharge at Centrifugal Pump Outlet
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Sagar S Kulkarni
Dayananda Sagar College of Engineering (DSCE), Bengaluru
Sagar S Kulkarni has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Vaibhav Malani
National Institute of Technology (NIT), Tiruchirapalli
Vaibhav Malani has verified this Calculator and 200+ more calculators!

Geometric and Flow Parameters Calculators

Volume of liquid at inlet
​ LaTeX ​ Go Actual Discharge at Centrifugal Pump Outlet = pi*Diameter of Centrifugal Pump Impeller at Inlet*Width of Impeller at Inlet*Flow Velocity at Inlet of Centrifugal Pump
Speed ratio
​ LaTeX ​ Go Speed Ratio Centrifugal Pump = Tangential Velocity of Impeller at Outlet/sqrt(2*[g]*Manometric Head of Centrifugal Pump)
Weight of liquid
​ LaTeX ​ Go Weight of Liquid in Pump = Specific Weight of Liquid*Actual Discharge at Centrifugal Pump Outlet
Static head
​ LaTeX ​ Go Static Head of Centrifugal Pump = Suction Head of Centrifugal Pump+Delivery Head of Pump

Volume of liquid at outlet Formula

​LaTeX ​Go
Actual Discharge at Centrifugal Pump Outlet = pi*Diameter of Centrifugal Pump Impeller at Outlet*Width of Impeller at Outlet*Flow Velocity at Outlet of Centrifugal Pump
Q = pi*D2*B2*Vf2

What is whirl velocity?

The whirl velocity is the tangential component of absolute velocity at the blade inlet and outlet. This component of velocity is responsible for the whirling of the impeller.

How to Calculate Volume of liquid at outlet?

Volume of liquid at outlet calculator uses Actual Discharge at Centrifugal Pump Outlet = pi*Diameter of Centrifugal Pump Impeller at Outlet*Width of Impeller at Outlet*Flow Velocity at Outlet of Centrifugal Pump to calculate the Actual Discharge at Centrifugal Pump Outlet, Volume of liquid at outlet formula is defined as the quantity of fluid discharged from the outlet of a centrifugal pump, influenced by the geometric and flow parameters, providing a crucial indicator of the pump's performance and efficiency in various industrial and engineering applications. Actual Discharge at Centrifugal Pump Outlet is denoted by Q symbol.

How to calculate Volume of liquid at outlet using this online calculator? To use this online calculator for Volume of liquid at outlet, enter Diameter of Centrifugal Pump Impeller at Outlet (D2), Width of Impeller at Outlet (B2) & Flow Velocity at Outlet of Centrifugal Pump (Vf2) and hit the calculate button. Here is how the Volume of liquid at outlet calculation can be explained with given input values -> 0.055945 = pi*0.28*0.03*2.12.

FAQ

What is Volume of liquid at outlet?
Volume of liquid at outlet formula is defined as the quantity of fluid discharged from the outlet of a centrifugal pump, influenced by the geometric and flow parameters, providing a crucial indicator of the pump's performance and efficiency in various industrial and engineering applications and is represented as Q = pi*D2*B2*Vf2 or Actual Discharge at Centrifugal Pump Outlet = pi*Diameter of Centrifugal Pump Impeller at Outlet*Width of Impeller at Outlet*Flow Velocity at Outlet of Centrifugal Pump. Diameter of centrifugal pump impeller at outlet is the diameter of the impeller at the outlet of the centrifugal pump, The Width of Impeller at Outlet is the width of the impeller at the outlet of the pump & Flow velocity at outlet of centrifugal pump is the velocity of the fluid at the outlet of the impeller or the centrifugal pump.
How to calculate Volume of liquid at outlet?
Volume of liquid at outlet formula is defined as the quantity of fluid discharged from the outlet of a centrifugal pump, influenced by the geometric and flow parameters, providing a crucial indicator of the pump's performance and efficiency in various industrial and engineering applications is calculated using Actual Discharge at Centrifugal Pump Outlet = pi*Diameter of Centrifugal Pump Impeller at Outlet*Width of Impeller at Outlet*Flow Velocity at Outlet of Centrifugal Pump. To calculate Volume of liquid at outlet, you need Diameter of Centrifugal Pump Impeller at Outlet (D2), Width of Impeller at Outlet (B2) & Flow Velocity at Outlet of Centrifugal Pump (Vf2). With our tool, you need to enter the respective value for Diameter of Centrifugal Pump Impeller at Outlet, Width of Impeller at Outlet & Flow Velocity at Outlet of Centrifugal Pump and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Actual Discharge at Centrifugal Pump Outlet?
In this formula, Actual Discharge at Centrifugal Pump Outlet uses Diameter of Centrifugal Pump Impeller at Outlet, Width of Impeller at Outlet & Flow Velocity at Outlet of Centrifugal Pump. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Actual Discharge at Centrifugal Pump Outlet = pi*Diameter of Centrifugal Pump Impeller at Inlet*Width of Impeller at Inlet*Flow Velocity at Inlet of Centrifugal Pump
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!