Volume of crater from MRR Solution

STEP 0: Pre-Calculation Summary
Formula Used
Volume of Crater = Metal Removal Rate/Frequency of Charging
V = Zw/fc
This formula uses 3 Variables
Variables Used
Volume of Crater - (Measured in Square Meter) - Volume of crater is defined as the Volume of crater made by an electric spark during EDM.
Metal Removal Rate - (Measured in Cubic Meter per Second) - Metal removal rate (MRR) is the amount of material removed per time unit (usually per minute) when performing machining operations such as using a lathe or milling machine.
Frequency of Charging - (Measured in Hertz) - Frequency of charging is the frequency at which the circuit capacitor is charged.
STEP 1: Convert Input(s) to Base Unit
Metal Removal Rate: 80 Cubic Meter per Second --> 80 Cubic Meter per Second No Conversion Required
Frequency of Charging: 1600 Cycle per Second --> 1600 Hertz (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
V = Zw/fc --> 80/1600
Evaluating ... ...
V = 0.05
STEP 3: Convert Result to Output's Unit
0.05 Square Meter -->50000 Square Millimeter (Check conversion ​here)
FINAL ANSWER
50000 Square Millimeter <-- Volume of Crater
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Rajat Vishwakarma
University Institute of Technology RGPV (UIT - RGPV), Bhopal
Rajat Vishwakarma has created this Calculator and 400+ more calculators!
Verifier Image
Verified by Anshika Arya
National Institute Of Technology (NIT), Hamirpur
Anshika Arya has verified this Calculator and 2500+ more calculators!

Material removal rate (MRR) Calculators

Proportionality constant for MRR
​ LaTeX ​ Go Proportionality Constant of MRR = -(Material Removal Rate*(2*Resistance of the Charging Circuit*ln(1-(Voltage at any Time t/Voltage of Power Supply))))/Voltage at any Time t^2
Material removal rate, MRR
​ LaTeX ​ Go Material Removal Rate = -(Proportionality Constant of MRR*Voltage at any Time t^2)/(2*Resistance of the Charging Circuit*ln(1-(Voltage at any Time t/Voltage of Power Supply)))
Resistance of circuit
​ LaTeX ​ Go Resistance of the Charging Circuit = -(Proportionality Constant of MRR*Voltage at any Time t^2)/(2*Material Removal Rate*ln(1-(Voltage at any Time t/Voltage of Power Supply)))
Input power supply to achieve given MRR
​ LaTeX ​ Go Voltage of Power Supply = Voltage at any Time t/(1-exp(-(Proportionality Constant of MRR*Voltage at any Time t^2)/(2*Resistance of the Charging Circuit*Metal Removal Rate)))

Volume of crater from MRR Formula

​LaTeX ​Go
Volume of Crater = Metal Removal Rate/Frequency of Charging
V = Zw/fc

What factors affects surface finish during EDM ?

The amount of material removed and the surface finish produced is dependent upon the current in the spark. The material removed by the spark can be assumed to be a crater. The amount removed therefore will depend upon the crater depth, which is directly proportional to the current. Thus as the material removed increases and at the same time the surface finish also decreases. However, decreasing the current in the spark, but increasing its frequency will improve the surface finish in view of the small crater size, but at the same time the material removal rate can be maintained by increasing the frequency.

How to Calculate Volume of crater from MRR?

Volume of crater from MRR calculator uses Volume of Crater = Metal Removal Rate/Frequency of Charging to calculate the Volume of Crater, Volume of crater from MRR formula is defined as the Volume of crater made by an electric spark during EDM. Volume of Crater is denoted by V symbol.

How to calculate Volume of crater from MRR using this online calculator? To use this online calculator for Volume of crater from MRR, enter Metal Removal Rate (Zw) & Frequency of Charging (fc) and hit the calculate button. Here is how the Volume of crater from MRR calculation can be explained with given input values -> 5E+10 = 80/1600.

FAQ

What is Volume of crater from MRR?
Volume of crater from MRR formula is defined as the Volume of crater made by an electric spark during EDM and is represented as V = Zw/fc or Volume of Crater = Metal Removal Rate/Frequency of Charging. Metal removal rate (MRR) is the amount of material removed per time unit (usually per minute) when performing machining operations such as using a lathe or milling machine & Frequency of charging is the frequency at which the circuit capacitor is charged.
How to calculate Volume of crater from MRR?
Volume of crater from MRR formula is defined as the Volume of crater made by an electric spark during EDM is calculated using Volume of Crater = Metal Removal Rate/Frequency of Charging. To calculate Volume of crater from MRR, you need Metal Removal Rate (Zw) & Frequency of Charging (fc). With our tool, you need to enter the respective value for Metal Removal Rate & Frequency of Charging and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!