Volume of Conductor Material using Load Current (DC Three-Wire US) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Volume Of Conductor = 5*Resistivity*(Length of Wire DC^2)*(Current underground DC^2)/Line Losses
V = 5*ρ*(l^2)*(C1^2)/Pline
This formula uses 5 Variables
Variables Used
Volume Of Conductor - (Measured in Cubic Meter) - Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
Resistivity - (Measured in Ohm Meter) - Resistivity is the measure of how strongly a material opposes the flow of current through them.
Length of Wire DC - (Measured in Meter) - Length of Wire DC is the measurement or extent of something from end to end.
Current underground DC - (Measured in Ampere) - Current underground DC is defined as the current flowing through the overhead ac supply wire.
Line Losses - (Measured in Watt) - Line Losses is defined as the losses that are produced in the line.
STEP 1: Convert Input(s) to Base Unit
Resistivity: 1.7E-05 Ohm Meter --> 1.7E-05 Ohm Meter No Conversion Required
Length of Wire DC: 3.2 Meter --> 3.2 Meter No Conversion Required
Current underground DC: 3 Ampere --> 3 Ampere No Conversion Required
Line Losses: 0.6 Watt --> 0.6 Watt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
V = 5*ρ*(l^2)*(C1^2)/Pline --> 5*1.7E-05*(3.2^2)*(3^2)/0.6
Evaluating ... ...
V = 0.013056
STEP 3: Convert Result to Output's Unit
0.013056 Cubic Meter --> No Conversion Required
FINAL ANSWER
0.013056 Cubic Meter <-- Volume Of Conductor
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Wire Parameters Calculators

Length using Volume of Conductor Material(DC Three-Wire US)
​ LaTeX ​ Go Length of Wire DC = sqrt(Volume Of Conductor*Line Losses*(Maximum Voltage^2)/((5)*Resistivity*(Power Transmitted^2)))
Line Losses using Volume of Conductor Material(DC Three-Wire US)
​ LaTeX ​ Go Line Losses = 5*Resistivity*((Power Transmitted*Length of Wire DC)^2)/(Volume Of Conductor*(Maximum Voltage^2))
Area of X-section using Volume of Conductor Material(DC Three-Wire US)
​ LaTeX ​ Go Area of underground dc wire = Volume Of Conductor/(2.5*Length of Wire DC)
Constant using Volume of Conductor Material(DC Three-Wire US)
​ LaTeX ​ Go Constant underground dc = Volume Of Conductor/(1.25)

Volume of Conductor Material using Load Current (DC Three-Wire US) Formula

​LaTeX ​Go
Volume Of Conductor = 5*Resistivity*(Length of Wire DC^2)*(Current underground DC^2)/Line Losses
V = 5*ρ*(l^2)*(C1^2)/Pline

What is the volume of conductor material in DC Three-Wire underground system?

The volume of conductor material required in this system is 1.25 times that of 2-wire d.c.system with the one conductor earthed.

How to Calculate Volume of Conductor Material using Load Current (DC Three-Wire US)?

Volume of Conductor Material using Load Current (DC Three-Wire US) calculator uses Volume Of Conductor = 5*Resistivity*(Length of Wire DC^2)*(Current underground DC^2)/Line Losses to calculate the Volume Of Conductor, The Volume of Conductor Material using Load Current (DC Three-Wire US) formula is defined as the 3-dimensional space enclosed by a conductor material of a DC Three-Wire underground system. Volume Of Conductor is denoted by V symbol.

How to calculate Volume of Conductor Material using Load Current (DC Three-Wire US) using this online calculator? To use this online calculator for Volume of Conductor Material using Load Current (DC Three-Wire US), enter Resistivity (ρ), Length of Wire DC (l), Current underground DC (C1) & Line Losses (Pline) and hit the calculate button. Here is how the Volume of Conductor Material using Load Current (DC Three-Wire US) calculation can be explained with given input values -> 0.013056 = 5*1.7E-05*(3.2^2)*(3^2)/0.6.

FAQ

What is Volume of Conductor Material using Load Current (DC Three-Wire US)?
The Volume of Conductor Material using Load Current (DC Three-Wire US) formula is defined as the 3-dimensional space enclosed by a conductor material of a DC Three-Wire underground system and is represented as V = 5*ρ*(l^2)*(C1^2)/Pline or Volume Of Conductor = 5*Resistivity*(Length of Wire DC^2)*(Current underground DC^2)/Line Losses. Resistivity is the measure of how strongly a material opposes the flow of current through them, Length of Wire DC is the measurement or extent of something from end to end, Current underground DC is defined as the current flowing through the overhead ac supply wire & Line Losses is defined as the losses that are produced in the line.
How to calculate Volume of Conductor Material using Load Current (DC Three-Wire US)?
The Volume of Conductor Material using Load Current (DC Three-Wire US) formula is defined as the 3-dimensional space enclosed by a conductor material of a DC Three-Wire underground system is calculated using Volume Of Conductor = 5*Resistivity*(Length of Wire DC^2)*(Current underground DC^2)/Line Losses. To calculate Volume of Conductor Material using Load Current (DC Three-Wire US), you need Resistivity (ρ), Length of Wire DC (l), Current underground DC (C1) & Line Losses (Pline). With our tool, you need to enter the respective value for Resistivity, Length of Wire DC, Current underground DC & Line Losses and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Volume Of Conductor?
In this formula, Volume Of Conductor uses Resistivity, Length of Wire DC, Current underground DC & Line Losses. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Volume Of Conductor = 2.5*Area of underground dc wire*Length of Wire DC
  • Volume Of Conductor = 1.25*Constant underground dc
  • Volume Of Conductor = (5*(Power Transmitted^2)*Resistance underground DC*Length of Wire DC*Area of underground dc wire)/(Line Losses*(Maximum Voltage^2))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!