Volume of Conductor Material using Line Losses (1-Phase 2-Wire US) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Volume Of Conductor = 8*Resistivity*(Power Transmitted*Length of Underground AC Wire)^2/(Line Losses*(Maximum Voltage Underground AC*cos(Phase Difference))^2)
V = 8*ρ*(P*L)^2/(Ploss*(Vm*cos(Φ))^2)
This formula uses 1 Functions, 7 Variables
Functions Used
cos - Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle., cos(Angle)
Variables Used
Volume Of Conductor - (Measured in Cubic Meter) - Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
Resistivity - (Measured in Ohm Meter) - Resistivity is the measure of how strongly a material opposes the flow of current through them.
Power Transmitted - (Measured in Watt) - Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Length of Underground AC Wire - (Measured in Meter) - Length of Underground AC Wire is the total length of the wire from one end to other end.
Line Losses - (Measured in Watt) - Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Maximum Voltage Underground AC - (Measured in Volt) - Maximum Voltage Underground AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Phase Difference - (Measured in Radian) - Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
STEP 1: Convert Input(s) to Base Unit
Resistivity: 1.7E-05 Ohm Meter --> 1.7E-05 Ohm Meter No Conversion Required
Power Transmitted: 300 Watt --> 300 Watt No Conversion Required
Length of Underground AC Wire: 24 Meter --> 24 Meter No Conversion Required
Line Losses: 2.67 Watt --> 2.67 Watt No Conversion Required
Maximum Voltage Underground AC: 230 Volt --> 230 Volt No Conversion Required
Phase Difference: 30 Degree --> 0.5235987755982 Radian (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
V = 8*ρ*(P*L)^2/(Ploss*(Vm*cos(Φ))^2) --> 8*1.7E-05*(300*24)^2/(2.67*(230*cos(0.5235987755982))^2)
Evaluating ... ...
V = 0.066554236316136
STEP 3: Convert Result to Output's Unit
0.066554236316136 Cubic Meter --> No Conversion Required
FINAL ANSWER
0.066554236316136 0.066554 Cubic Meter <-- Volume Of Conductor
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

Wire Parameters Calculators

Area of X-Section (1-Phase 2-Wire US)
​ LaTeX ​ Go Area of Underground AC Wire = (4)*Resistivity*Length of Underground AC Wire*(Power Transmitted)^2/(Line Losses*(Maximum Voltage Underground AC*cos(Phase Difference))^2)
Constant (1-Phase 2-Wire US)
​ LaTeX ​ Go Constant Underground AC = 4*Resistivity*(Power Transmitted*Length of Underground AC Wire)^2/(Line Losses*(Maximum Voltage Underground AC)^2)
Voltage of Conductor Material (1-Phase 2-Wire US)
​ LaTeX ​ Go Volume Of Conductor = 2*Constant Underground AC/(cos(Phase Difference))^2
Area of X-Section using Volume of Conductor Material (1-Phase 2-Wire US)
​ LaTeX ​ Go Area of Underground AC Wire = Volume Of Conductor/(2*Length of Underground AC Wire)

Volume of Conductor Material using Line Losses (1-Phase 2-Wire US) Formula

​LaTeX ​Go
Volume Of Conductor = 8*Resistivity*(Power Transmitted*Length of Underground AC Wire)^2/(Line Losses*(Maximum Voltage Underground AC*cos(Phase Difference))^2)
V = 8*ρ*(P*L)^2/(Ploss*(Vm*cos(Φ))^2)

What is the value of maximum voltage and volume of conductor material in 1-phase 2-wire system?

The volume of conductor material required in this system is 2/cos2θ times that of 2-wire d.c.system with the one conductor earthed. The maximum voltage between conductors is vm so that r.m.s. value of voltage between them is vm/√2.

How to Calculate Volume of Conductor Material using Line Losses (1-Phase 2-Wire US)?

Volume of Conductor Material using Line Losses (1-Phase 2-Wire US) calculator uses Volume Of Conductor = 8*Resistivity*(Power Transmitted*Length of Underground AC Wire)^2/(Line Losses*(Maximum Voltage Underground AC*cos(Phase Difference))^2) to calculate the Volume Of Conductor, The Volume of Conductor Material using Line Losses (1-Phase 2-Wire US) formula is defined as the 3-dimensional space enclosed by a conductor material of a single-phase two-wire overhead system. Volume Of Conductor is denoted by V symbol.

How to calculate Volume of Conductor Material using Line Losses (1-Phase 2-Wire US) using this online calculator? To use this online calculator for Volume of Conductor Material using Line Losses (1-Phase 2-Wire US), enter Resistivity (ρ), Power Transmitted (P), Length of Underground AC Wire (L), Line Losses (Ploss), Maximum Voltage Underground AC (Vm) & Phase Difference (Φ) and hit the calculate button. Here is how the Volume of Conductor Material using Line Losses (1-Phase 2-Wire US) calculation can be explained with given input values -> 0.066554 = 8*1.7E-05*(300*24)^2/(2.67*(230*cos(0.5235987755982))^2).

FAQ

What is Volume of Conductor Material using Line Losses (1-Phase 2-Wire US)?
The Volume of Conductor Material using Line Losses (1-Phase 2-Wire US) formula is defined as the 3-dimensional space enclosed by a conductor material of a single-phase two-wire overhead system and is represented as V = 8*ρ*(P*L)^2/(Ploss*(Vm*cos(Φ))^2) or Volume Of Conductor = 8*Resistivity*(Power Transmitted*Length of Underground AC Wire)^2/(Line Losses*(Maximum Voltage Underground AC*cos(Phase Difference))^2). Resistivity is the measure of how strongly a material opposes the flow of current through them, Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work, Length of Underground AC Wire is the total length of the wire from one end to other end, Line Losses is defined as the total losses occurring in an Underground AC line when in use, Maximum Voltage Underground AC is defined as the peak amplitude of the AC voltage supplied to the line or wire & Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
How to calculate Volume of Conductor Material using Line Losses (1-Phase 2-Wire US)?
The Volume of Conductor Material using Line Losses (1-Phase 2-Wire US) formula is defined as the 3-dimensional space enclosed by a conductor material of a single-phase two-wire overhead system is calculated using Volume Of Conductor = 8*Resistivity*(Power Transmitted*Length of Underground AC Wire)^2/(Line Losses*(Maximum Voltage Underground AC*cos(Phase Difference))^2). To calculate Volume of Conductor Material using Line Losses (1-Phase 2-Wire US), you need Resistivity (ρ), Power Transmitted (P), Length of Underground AC Wire (L), Line Losses (Ploss), Maximum Voltage Underground AC (Vm) & Phase Difference (Φ). With our tool, you need to enter the respective value for Resistivity, Power Transmitted, Length of Underground AC Wire, Line Losses, Maximum Voltage Underground AC & Phase Difference and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Volume Of Conductor?
In this formula, Volume Of Conductor uses Resistivity, Power Transmitted, Length of Underground AC Wire, Line Losses, Maximum Voltage Underground AC & Phase Difference. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Volume Of Conductor = 2*Constant Underground AC/(cos(Phase Difference))^2
  • Volume Of Conductor = Area of Underground AC Wire*Length of Underground AC Wire*2
  • Volume Of Conductor = 4*(Current Underground AC^2)*Resistivity*(Length of Underground AC Wire^2)/(Line Losses)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!