Volatile Solids produced given Percent Stabilization Solution

STEP 0: Pre-Calculation Summary
Formula Used
Volatile Solids Produced = (1/1.42)*(BOD In-BOD Out-((Percent Stabilization*BOD In)/100))
Px = (1/1.42)*(BODin-BODout-((%S*BODin)/100))
This formula uses 4 Variables
Variables Used
Volatile Solids Produced - (Measured in Kilogram per Second) - Volatile Solids Produced refers to the organic fraction of the total solids present in the sludge.
BOD In - (Measured in Kilogram per Second) - BOD In in anaerobic digester design lies in its role as an indicator of the organic load present in the feedstock. High BOD levels suggest a greater concentration of organic matter.
BOD Out - (Measured in Kilogram per Second) - BOD Out referred as the amount of dissolved oxygen exits anaerobic digester.
Percent Stabilization - Percent Stabilization is defined as percentage of bod removal.
STEP 1: Convert Input(s) to Base Unit
BOD In: 164 Kilogram per Day --> 0.00189814814814815 Kilogram per Second (Check conversion ​here)
BOD Out: 4.9 Kilogram per Day --> 5.6712962962963E-05 Kilogram per Second (Check conversion ​here)
Percent Stabilization: 10.36 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Px = (1/1.42)*(BODin-BODout-((%S*BODin)/100)) --> (1/1.42)*(0.00189814814814815-5.6712962962963E-05-((10.36*0.00189814814814815)/100))
Evaluating ... ...
Px = 0.00115830073030777
STEP 3: Convert Result to Output's Unit
0.00115830073030777 Kilogram per Second -->100.077183098592 Kilogram per Day (Check conversion ​here)
FINAL ANSWER
100.077183098592 100.0772 Kilogram per Day <-- Volatile Solids Produced
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Design of an Anaerobic Digester Calculators

Influent Sludge Flow Rate given Volume Required for Anaerobic Digester
​ LaTeX ​ Go Influent Sludge Flow Rate = (Volume/Hydraulic Retention Time)
Volume Required for Anaerobic Digester
​ LaTeX ​ Go Volume = (Hydraulic Retention Time*Influent Sludge Flow Rate)
Hydraulic Retention Time given Volume Required for Anaerobic Digester
​ LaTeX ​ Go Hydraulic Retention = (Volume/Influent Sludge Flow Rate)
Volumetric Loading in Anaerobic Digester
​ LaTeX ​ Go Volumetric Loading = (BOD per Day/Volumetric Flow Rate)

Volatile Solids produced given Percent Stabilization Formula

​LaTeX ​Go
Volatile Solids Produced = (1/1.42)*(BOD In-BOD Out-((Percent Stabilization*BOD In)/100))
Px = (1/1.42)*(BODin-BODout-((%S*BODin)/100))

What are Volatile Solids?

Volatile Solids are a substance that can easily transform from its solid phase to its vapour phase without going through a liquid phase. Volatile solids normally represent the amount of organic solids in water, and have great importance in water and wastewater treatment.

How to Calculate Volatile Solids produced given Percent Stabilization?

Volatile Solids produced given Percent Stabilization calculator uses Volatile Solids Produced = (1/1.42)*(BOD In-BOD Out-((Percent Stabilization*BOD In)/100)) to calculate the Volatile Solids Produced, The Volatile Solids Produced given Percent Stabilization is a substance that can easily transform from its solid phase to its vapor phase without going through a liquid phase. Volatile Solids Produced is denoted by Px symbol.

How to calculate Volatile Solids produced given Percent Stabilization using this online calculator? To use this online calculator for Volatile Solids produced given Percent Stabilization, enter BOD In (BODin), BOD Out (BODout) & Percent Stabilization (%S) and hit the calculate button. Here is how the Volatile Solids produced given Percent Stabilization calculation can be explained with given input values -> 8.6E+6 = (1/1.42)*(0.00189814814814815-5.6712962962963E-05-((10.36*0.00189814814814815)/100)).

FAQ

What is Volatile Solids produced given Percent Stabilization?
The Volatile Solids Produced given Percent Stabilization is a substance that can easily transform from its solid phase to its vapor phase without going through a liquid phase and is represented as Px = (1/1.42)*(BODin-BODout-((%S*BODin)/100)) or Volatile Solids Produced = (1/1.42)*(BOD In-BOD Out-((Percent Stabilization*BOD In)/100)). BOD In in anaerobic digester design lies in its role as an indicator of the organic load present in the feedstock. High BOD levels suggest a greater concentration of organic matter, BOD Out referred as the amount of dissolved oxygen exits anaerobic digester & Percent Stabilization is defined as percentage of bod removal.
How to calculate Volatile Solids produced given Percent Stabilization?
The Volatile Solids Produced given Percent Stabilization is a substance that can easily transform from its solid phase to its vapor phase without going through a liquid phase is calculated using Volatile Solids Produced = (1/1.42)*(BOD In-BOD Out-((Percent Stabilization*BOD In)/100)). To calculate Volatile Solids produced given Percent Stabilization, you need BOD In (BODin), BOD Out (BODout) & Percent Stabilization (%S). With our tool, you need to enter the respective value for BOD In, BOD Out & Percent Stabilization and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Volatile Solids Produced?
In this formula, Volatile Solids Produced uses BOD In, BOD Out & Percent Stabilization. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Volatile Solids Produced = (Yield Coefficient*(BOD In-BOD Out))/(1-Endogenous Coefficient*Mean Cell Residence Time)
  • Volatile Solids Produced = (1/1.42)*(BOD In-BOD Out-(Volume of Methane/5.62))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!