How to Calculate Void Ratio given Total Pressure per unit Area for Dams on Soft Foundations?
Void Ratio given Total Pressure per unit Area for Dams on Soft Foundations calculator uses Void Ratio = (Degree of Saturation-(Total Pressure at given Point/(Depth of Dam*Specific Weight of Water in KN per cubic meter)))/((Total Pressure at given Point/(Depth of Dam*Specific Weight of Water in KN per cubic meter))-1) to calculate the Void Ratio, The Void Ratio given Total Pressure per unit Area for Dams on Soft Foundations formula is defined as the ratio of volume of void to volume of soil. Void Ratio is denoted by e symbol.
How to calculate Void Ratio given Total Pressure per unit Area for Dams on Soft Foundations using this online calculator? To use this online calculator for Void Ratio given Total Pressure per unit Area for Dams on Soft Foundations, enter Degree of Saturation (S), Total Pressure at given Point (P0), Depth of Dam (D) & Specific Weight of Water in KN per cubic meter (W) and hit the calculate button. Here is how the Void Ratio given Total Pressure per unit Area for Dams on Soft Foundations calculation can be explained with given input values -> 1.20257 = (7-(109.6/(3*9810)))/((109.6/(3*9810))-1).