Viscosity of Wall using Wall Temperature and Static Temperature Solution

STEP 0: Pre-Calculation Summary
Formula Used
Wall Viscosity = Static Viscosity*Wall Temperature/Static Temperature
μw = μe*Tw/Tstatic
This formula uses 4 Variables
Variables Used
Wall Viscosity - (Measured in Pascal Second) - Wall viscosity is the viscosity of fluid in near wall during the turbulent flow.
Static Viscosity - (Measured in Pascal Second) - Static viscosity, is the viscosity of continuous flow, viscosity measures the ratio of the viscous force to the inertial force on the fluid.
Wall Temperature - (Measured in Kelvin) - Wall Temperature is the temperature at the wall.
Static Temperature - (Measured in Kelvin) - The Static Temperature is defined as the temperature of the gas if it had no ordered motion and was not flowing.
STEP 1: Convert Input(s) to Base Unit
Static Viscosity: 11.2 Poise --> 1.12 Pascal Second (Check conversion ​here)
Wall Temperature: 15 Kelvin --> 15 Kelvin No Conversion Required
Static Temperature: 350 Kelvin --> 350 Kelvin No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
μw = μe*Tw/Tstatic --> 1.12*15/350
Evaluating ... ...
μw = 0.048
STEP 3: Convert Result to Output's Unit
0.048 Pascal Second -->0.48 Poise (Check conversion ​here)
FINAL ANSWER
0.48 Poise <-- Wall Viscosity
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Sanjay Krishna
Amrita School of Engineering (ASE), Vallikavu
Sanjay Krishna has created this Calculator and 300+ more calculators!
Verifier Image
Verified by Maiarutselvan V
PSG College of Technology (PSGCT), Coimbatore
Maiarutselvan V has verified this Calculator and 300+ more calculators!

Supersonic Aerothermodynamics Calculators

Mach Number over Flat Plate using Static Temperature and Wall Temperature
​ LaTeX ​ Go Mach Number = sqrt((Temperature of Wall in Kelvin/Static Temperature-1)/((Specific Heat Ratio-1)/2))
Total Temperature over Flat Plate under Viscous Mach Flow
​ LaTeX ​ Go Total Temperature = Static Temperature+Static Temperature*((Specific Heat Ratio-1)/2)*Mach Number^2
Viscosity of Wall using Wall Temperature and Static Temperature
​ LaTeX ​ Go Wall Viscosity = Static Viscosity*Wall Temperature/Static Temperature
Wall Density of Fluid over Flat Plate
​ LaTeX ​ Go Wall Density = Static Density/(Wall Temperature/Static Temperature)

Viscosity of Wall using Wall Temperature and Static Temperature Formula

​LaTeX ​Go
Wall Viscosity = Static Viscosity*Wall Temperature/Static Temperature
μw = μe*Tw/Tstatic

What is Viscosity ?

Viscosity is a measure of a fluid's resistance to flow. It describes the internal friction of a moving fluid. A fluid with large viscosity resists motion because its molecular makeup gives it a lot of internal friction.

How to Calculate Viscosity of Wall using Wall Temperature and Static Temperature?

Viscosity of Wall using Wall Temperature and Static Temperature calculator uses Wall Viscosity = Static Viscosity*Wall Temperature/Static Temperature to calculate the Wall Viscosity, The viscosity of wall using wall temperature and static temperature formula is defined as the product of static viscosity and ratio of the wall and static temperature. Wall Viscosity is denoted by μw symbol.

How to calculate Viscosity of Wall using Wall Temperature and Static Temperature using this online calculator? To use this online calculator for Viscosity of Wall using Wall Temperature and Static Temperature, enter Static Viscosity (μe), Wall Temperature (Tw) & Static Temperature (Tstatic) and hit the calculate button. Here is how the Viscosity of Wall using Wall Temperature and Static Temperature calculation can be explained with given input values -> 4.8 = 1.12*15/350.

FAQ

What is Viscosity of Wall using Wall Temperature and Static Temperature?
The viscosity of wall using wall temperature and static temperature formula is defined as the product of static viscosity and ratio of the wall and static temperature and is represented as μw = μe*Tw/Tstatic or Wall Viscosity = Static Viscosity*Wall Temperature/Static Temperature. Static viscosity, is the viscosity of continuous flow, viscosity measures the ratio of the viscous force to the inertial force on the fluid, Wall Temperature is the temperature at the wall & The Static Temperature is defined as the temperature of the gas if it had no ordered motion and was not flowing.
How to calculate Viscosity of Wall using Wall Temperature and Static Temperature?
The viscosity of wall using wall temperature and static temperature formula is defined as the product of static viscosity and ratio of the wall and static temperature is calculated using Wall Viscosity = Static Viscosity*Wall Temperature/Static Temperature. To calculate Viscosity of Wall using Wall Temperature and Static Temperature, you need Static Viscosity (μe), Wall Temperature (Tw) & Static Temperature (Tstatic). With our tool, you need to enter the respective value for Static Viscosity, Wall Temperature & Static Temperature and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!