Vertical Tube Loading given Reynolds Number for Condensate Film Solution

STEP 0: Pre-Calculation Summary
Formula Used
Tube Loading = (Reynolds Number for Condensate Film*Fluid Viscosity at Average Temperature)/4
Γv = (Rec*μ)/4
This formula uses 3 Variables
Variables Used
Tube Loading - Tube Loading refers to the thin film of the condensate which is formed during the condensation of vapors in a condenser type heat exchanger.
Reynolds Number for Condensate Film - Reynolds Number for Condensate Film is a dimensionless parameter used to characterize the flow of a condensate film over a surface.
Fluid Viscosity at Average Temperature - (Measured in Pascal Second) - Fluid viscosity at Average Temperature in Heat Exchanger is a fundamental property of fluids that characterizes their resistance to flow in a heat exchanger.
STEP 1: Convert Input(s) to Base Unit
Reynolds Number for Condensate Film: 3.809896 --> No Conversion Required
Fluid Viscosity at Average Temperature: 1.005 Pascal Second --> 1.005 Pascal Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Γv = (Rec*μ)/4 --> (3.809896*1.005)/4
Evaluating ... ...
Γv = 0.95723637
STEP 3: Convert Result to Output's Unit
0.95723637 --> No Conversion Required
FINAL ANSWER
0.95723637 0.957236 <-- Tube Loading
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Rishi Vadodaria
Malviya National Institute Of Technology (MNIT JAIPUR ), JAIPUR
Rishi Vadodaria has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Vaibhav Mishra
DJ Sanghvi College of Engineering (DJSCE), Mumbai
Vaibhav Mishra has verified this Calculator and 200+ more calculators!

Heat Transfer Coefficient in Heat Exchangers Calculators

Heat Transfer Coefficient for Condensation Outside Horizontal Tubes
​ LaTeX ​ Go Average Condensation Coefficient = 0.95*Thermal Conductivity in Heat Exchanger*((Fluid Density in Heat Transfer*(Fluid Density in Heat Transfer-Density of Vapor)*([g]/Fluid Viscosity at Average Temperature)*(Number of Tubes in Heat Exchanger*Length of Tube in Heat Exchanger/Mass Flowrate in Heat Exchanger))^(1/3))*(Number of Tubes in Vertical Row of Exchanger^(-1/6))
Heat Transfer Coefficient for Condensation Inside Vertical Tubes
​ LaTeX ​ Go Average Condensation Coefficient = 0.926*Thermal Conductivity in Heat Exchanger*((Fluid Density in Heat Transfer/Fluid Viscosity at Average Temperature)*(Fluid Density in Heat Transfer-Density of Vapor)*[g]*(pi*Pipe Inner Diameter in Exchanger*Number of Tubes in Heat Exchanger/Mass Flowrate in Heat Exchanger))^(1/3)
Heat Transfer Coefficient for Condensation Outside Vertical Tubes
​ LaTeX ​ Go Average Condensation Coefficient = 0.926*Thermal Conductivity in Heat Exchanger*((Fluid Density in Heat Transfer/Fluid Viscosity at Average Temperature)*(Fluid Density in Heat Transfer-Density of Vapor)*[g]*(pi*Pipe Outer Dia*Number of Tubes in Heat Exchanger/Mass Flowrate in Heat Exchanger))^(1/3)
Heat Transfer Coefficient for Plate Heat Exchanger
​ LaTeX ​ Go Plate Film Coefficient = 0.26*(Thermal Conductivity in Heat Exchanger/Equivalent Diameter in Heat Exchanger)*(Reynold Number for Fluid^0.65)*(Prandlt Number for Fluid^0.4)*(Fluid Viscosity at Average Temperature/Fluid Viscosity at Tube Wall Temperature)^0.14

Vertical Tube Loading given Reynolds Number for Condensate Film Formula

​LaTeX ​Go
Tube Loading = (Reynolds Number for Condensate Film*Fluid Viscosity at Average Temperature)/4
Γv = (Rec*μ)/4

What is the Significance of Tube Loading in Condenser?

Tube loading in a condenser refers to the amount of vapor or gas that the condenser is designed to handle, and it is a critical parameter in the design and operation of the condensation process. Tube loading directly affects the capacity of the condenser, determining the maximum amount of vapor it can efficiently handle. Understanding tube loading is crucial for designing condensers that can meet the required throughput of a process. Tube loading considerations help in determining the optimal flow rate of the cooling medium (often water) through the condenser. Controlling the cooling medium flow rate is essential for maintaining the desired temperature conditions for condensation.

How to Calculate Vertical Tube Loading given Reynolds Number for Condensate Film?

Vertical Tube Loading given Reynolds Number for Condensate Film calculator uses Tube Loading = (Reynolds Number for Condensate Film*Fluid Viscosity at Average Temperature)/4 to calculate the Tube Loading, The Vertical Tube Loading given Reynolds Number for Condensate Film formula is defined as film formation that occurs over the tubes in a vertical condenser while the vapor gets condensed over the tubes. Tube Loading is denoted by Γv symbol.

How to calculate Vertical Tube Loading given Reynolds Number for Condensate Film using this online calculator? To use this online calculator for Vertical Tube Loading given Reynolds Number for Condensate Film, enter Reynolds Number for Condensate Film (Rec) & Fluid Viscosity at Average Temperature (μ) and hit the calculate button. Here is how the Vertical Tube Loading given Reynolds Number for Condensate Film calculation can be explained with given input values -> 0.957236 = (3.809896*1.005)/4.

FAQ

What is Vertical Tube Loading given Reynolds Number for Condensate Film?
The Vertical Tube Loading given Reynolds Number for Condensate Film formula is defined as film formation that occurs over the tubes in a vertical condenser while the vapor gets condensed over the tubes and is represented as Γv = (Rec*μ)/4 or Tube Loading = (Reynolds Number for Condensate Film*Fluid Viscosity at Average Temperature)/4. Reynolds Number for Condensate Film is a dimensionless parameter used to characterize the flow of a condensate film over a surface & Fluid viscosity at Average Temperature in Heat Exchanger is a fundamental property of fluids that characterizes their resistance to flow in a heat exchanger.
How to calculate Vertical Tube Loading given Reynolds Number for Condensate Film?
The Vertical Tube Loading given Reynolds Number for Condensate Film formula is defined as film formation that occurs over the tubes in a vertical condenser while the vapor gets condensed over the tubes is calculated using Tube Loading = (Reynolds Number for Condensate Film*Fluid Viscosity at Average Temperature)/4. To calculate Vertical Tube Loading given Reynolds Number for Condensate Film, you need Reynolds Number for Condensate Film (Rec) & Fluid Viscosity at Average Temperature (μ). With our tool, you need to enter the respective value for Reynolds Number for Condensate Film & Fluid Viscosity at Average Temperature and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Tube Loading?
In this formula, Tube Loading uses Reynolds Number for Condensate Film & Fluid Viscosity at Average Temperature. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Tube Loading = Condensate Flow/(Number of Tubes in Heat Exchanger*pi*Pipe Inner Diameter in Exchanger)