Vertical Isothermal Cylinder Buried in Semi-Infinite Medium Solution

STEP 0: Pre-Calculation Summary
Formula Used
Conduction Shape Factor = (2*pi*Length of Cylinder 1)/(ln((4*Length of Cylinder 1)/Diameter of Cylinder 1))
S = (2*pi*lc)/(ln((4*lc)/D1))
This formula uses 1 Constants, 1 Functions, 3 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
Functions Used
ln - The natural logarithm, also known as the logarithm to the base e, is the inverse function of the natural exponential function., ln(Number)
Variables Used
Conduction Shape Factor - (Measured in Meter) - Conduction shape factor is defined as the value used to determine the heat transfer rate for the configurations which are very complex and require high calculation time.
Length of Cylinder 1 - (Measured in Meter) - Length of Cylinder 1 is the vertical height of the Cylinder.
Diameter of Cylinder 1 - (Measured in Meter) - Diameter of Cylinder 1 is the diameter of the first cylinder.
STEP 1: Convert Input(s) to Base Unit
Length of Cylinder 1: 8.40313 Meter --> 8.40313 Meter No Conversion Required
Diameter of Cylinder 1: 5.1 Meter --> 5.1 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
S = (2*pi*lc)/(ln((4*lc)/D1)) --> (2*pi*8.40313)/(ln((4*8.40313)/5.1))
Evaluating ... ...
S = 27.9999983017307
STEP 3: Convert Result to Output's Unit
27.9999983017307 Meter --> No Conversion Required
FINAL ANSWER
27.9999983017307 28 Meter <-- Conduction Shape Factor
(Calculation completed in 00.014 seconds)

Credits

Creator Image
Created by Ravi Khiyani
Shri Govindram Seksaria Institute of Technology and Science (SGSITS), Indore
Ravi Khiyani has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Anshika Arya
National Institute Of Technology (NIT), Hamirpur
Anshika Arya has verified this Calculator and 2500+ more calculators!

Semi Infinite Medium Calculators

Row of Equally Spaced Parallel Isothermal Cylinders Buried in Semi-infinite Medium
​ LaTeX ​ Go Conduction Shape Factor 2 = (2*pi*Length of Cylinder)/(ln((2*Distance Between Centers)/(pi*Diameter of Cylinder)*sinh((2*pi*Distance from Surface to Centre of Object)/Distance Between Centers)))
Isothermal Sphere Buried in Semi-Infinite Medium whose Surface is Insulated
​ LaTeX ​ Go Conduction Shape Factor = (2*pi*Diameter of Sphere Insulated)/(1+(0.25*Diameter of Sphere Insulated)/Distance from Surface to Centre of Object)
Vertical Isothermal Cylinder Buried in Semi-Infinite Medium
​ LaTeX ​ Go Conduction Shape Factor = (2*pi*Length of Cylinder 1)/(ln((4*Length of Cylinder 1)/Diameter of Cylinder 1))
Thin Rectangular Plate Buried in Semi-Infinite Medium
​ LaTeX ​ Go Conduction Shape Factor = (2*pi*Width of Plate)/ln((4*Width of Plate)/Length of Plate)

Vertical Isothermal Cylinder Buried in Semi-Infinite Medium Formula

​LaTeX ​Go
Conduction Shape Factor = (2*pi*Length of Cylinder 1)/(ln((4*Length of Cylinder 1)/Diameter of Cylinder 1))
S = (2*pi*lc)/(ln((4*lc)/D1))

Why we use conduction shape factor?

Conduction shape factors are generally used when the geometries and configurations of the system are complex which makes the calculation of heat transfer very difficult.

How to Calculate Vertical Isothermal Cylinder Buried in Semi-Infinite Medium?

Vertical Isothermal Cylinder Buried in Semi-Infinite Medium calculator uses Conduction Shape Factor = (2*pi*Length of Cylinder 1)/(ln((4*Length of Cylinder 1)/Diameter of Cylinder 1)) to calculate the Conduction Shape Factor, Vertical Isothermal Cylinder Buried in Semi-Infinite Medium formula is defined as a measure of the thermal resistance of a cylinder buried in a semi-infinite medium, which is essential in understanding heat transfer and thermal conduction in various engineering applications. Conduction Shape Factor is denoted by S symbol.

How to calculate Vertical Isothermal Cylinder Buried in Semi-Infinite Medium using this online calculator? To use this online calculator for Vertical Isothermal Cylinder Buried in Semi-Infinite Medium, enter Length of Cylinder 1 (lc) & Diameter of Cylinder 1 (D1) and hit the calculate button. Here is how the Vertical Isothermal Cylinder Buried in Semi-Infinite Medium calculation can be explained with given input values -> 26.81966 = (2*pi*8.40313)/(ln((4*8.40313)/5.1)).

FAQ

What is Vertical Isothermal Cylinder Buried in Semi-Infinite Medium?
Vertical Isothermal Cylinder Buried in Semi-Infinite Medium formula is defined as a measure of the thermal resistance of a cylinder buried in a semi-infinite medium, which is essential in understanding heat transfer and thermal conduction in various engineering applications and is represented as S = (2*pi*lc)/(ln((4*lc)/D1)) or Conduction Shape Factor = (2*pi*Length of Cylinder 1)/(ln((4*Length of Cylinder 1)/Diameter of Cylinder 1)). Length of Cylinder 1 is the vertical height of the Cylinder & Diameter of Cylinder 1 is the diameter of the first cylinder.
How to calculate Vertical Isothermal Cylinder Buried in Semi-Infinite Medium?
Vertical Isothermal Cylinder Buried in Semi-Infinite Medium formula is defined as a measure of the thermal resistance of a cylinder buried in a semi-infinite medium, which is essential in understanding heat transfer and thermal conduction in various engineering applications is calculated using Conduction Shape Factor = (2*pi*Length of Cylinder 1)/(ln((4*Length of Cylinder 1)/Diameter of Cylinder 1)). To calculate Vertical Isothermal Cylinder Buried in Semi-Infinite Medium, you need Length of Cylinder 1 (lc) & Diameter of Cylinder 1 (D1). With our tool, you need to enter the respective value for Length of Cylinder 1 & Diameter of Cylinder 1 and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Conduction Shape Factor?
In this formula, Conduction Shape Factor uses Length of Cylinder 1 & Diameter of Cylinder 1. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Conduction Shape Factor = (2*pi*Width of Plate)/ln((4*Width of Plate)/Length of Plate)
  • Conduction Shape Factor = (2*pi*Diameter of Sphere Insulated)/(1+(0.25*Diameter of Sphere Insulated)/Distance from Surface to Centre of Object)
  • Conduction Shape Factor = (2*pi*Diameter of Sphere)/(1-((0.25*Diameter of Sphere)/Distance from Surface to Centre of Object))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!