Venturi Head given Theoretical Discharge through Pipe Solution

STEP 0: Pre-Calculation Summary
Formula Used
Venturi Head = ((Theoretical Discharge/(Cross Section Area 1*Cross Section Area 2))*(sqrt(((Cross Section Area 1)^2-(Cross Section Area 2)^2)/(2*[g]))))^2
hventuri = ((Qth/(Ai*Af))*(sqrt(((Ai)^2-(Af)^2)/(2*[g]))))^2
This formula uses 1 Constants, 1 Functions, 4 Variables
Constants Used
[g] - Gravitational acceleration on Earth Value Taken As 9.80665
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Venturi Head - (Measured in Meter) - The Venturi head refers to the difference between pressure head at inlet and pressure head at the throat.
Theoretical Discharge - (Measured in Cubic Meter per Second) - The Theoretical Discharge refers to the ideal flow rate of a fluid through a system, calculated under perfect conditions without considering any real-world losses like friction or turbulence.
Cross Section Area 1 - (Measured in Square Meter) - The Cross Section Area 1 refers to the area of cross section at the inlet of the structure (venturi meter or pipe).
Cross Section Area 2 - (Measured in Square Meter) - The Cross Section Area 2 refers to the area of cross-section at the throat (venturi meter) of the structure.
STEP 1: Convert Input(s) to Base Unit
Theoretical Discharge: 1.277 Cubic Meter per Second --> 1.277 Cubic Meter per Second No Conversion Required
Cross Section Area 1: 7.1 Square Meter --> 7.1 Square Meter No Conversion Required
Cross Section Area 2: 1.8 Square Meter --> 1.8 Square Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
hventuri = ((Qth/(Ai*Af))*(sqrt(((Ai)^2-(Af)^2)/(2*[g]))))^2 --> ((1.277/(7.1*1.8))*(sqrt(((7.1)^2-(1.8)^2)/(2*[g]))))^2
Evaluating ... ...
hventuri = 0.0240123846645442
STEP 3: Convert Result to Output's Unit
0.0240123846645442 Meter -->24.0123846645442 Millimeter (Check conversion ​here)
FINAL ANSWER
24.0123846645442 24.01238 Millimeter <-- Venturi Head
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Rithik Agrawal
National Institute of Technology Karnataka (NITK), Surathkal
Rithik Agrawal has created this Calculator and 1300+ more calculators!
Verifier Image
Verified by M Naveen
National Institute of Technology (NIT), Warangal
M Naveen has verified this Calculator and 900+ more calculators!

Venturi Meter Calculators

Theoretical Discharge through Pipe
​ LaTeX ​ Go Theoretical Discharge = (Cross Section Area 1*Cross Section Area 2*(sqrt(2*[g]*Venturi Head)))/(sqrt((Cross Section Area 1)^(2)-(Cross Section Area 2)^(2)))
Venturi Head given Theoretical Discharge through Pipe
​ LaTeX ​ Go Venturi Head = ((Theoretical Discharge/(Cross Section Area 1*Cross Section Area 2))*(sqrt(((Cross Section Area 1)^2-(Cross Section Area 2)^2)/(2*[g]))))^2
Inlet Area given Theoretical Discharge
​ LaTeX ​ Go Cross Section Area 1 = sqrt(((Theoretical Discharge*Cross Section Area 2)^2)/((Theoretical Discharge)^2-(Cross Section Area 2^2*2*[g]*Venturi Head)))
Throat Area given Theoretical Discharge
​ LaTeX ​ Go Cross Section Area 2 = sqrt((Cross Section Area 1*Theoretical Discharge)^2/((Cross Section Area 1^2*2*[g]*Venturi Head)+Theoretical Discharge^2))

Venturi Head given Theoretical Discharge through Pipe Formula

​LaTeX ​Go
Venturi Head = ((Theoretical Discharge/(Cross Section Area 1*Cross Section Area 2))*(sqrt(((Cross Section Area 1)^2-(Cross Section Area 2)^2)/(2*[g]))))^2
hventuri = ((Qth/(Ai*Af))*(sqrt(((Ai)^2-(Af)^2)/(2*[g]))))^2

What is Venturi Head?

A Venturi meter is used to measure the flow rate through a tube. It is based on the use of the Venturi effect, the reduction of fluid pressure that results when a fluid runs through a constricted section of pipe. It is called after Giovanni Battista Venturi (1746-1822), an Italian physicist.

How to Calculate Venturi Head given Theoretical Discharge through Pipe?

Venturi Head given Theoretical Discharge through Pipe calculator uses Venturi Head = ((Theoretical Discharge/(Cross Section Area 1*Cross Section Area 2))*(sqrt(((Cross Section Area 1)^2-(Cross Section Area 2)^2)/(2*[g]))))^2 to calculate the Venturi Head, The Venturi Head given Theoretical Discharge through Pipe formula is defined as the total head loss in the flow of fluid through pipe. Venturi Head is denoted by hventuri symbol.

How to calculate Venturi Head given Theoretical Discharge through Pipe using this online calculator? To use this online calculator for Venturi Head given Theoretical Discharge through Pipe, enter Theoretical Discharge (Qth), Cross Section Area 1 (Ai) & Cross Section Area 2 (Af) and hit the calculate button. Here is how the Venturi Head given Theoretical Discharge through Pipe calculation can be explained with given input values -> 24012.38 = ((1.277/(7.1*1.8))*(sqrt(((7.1)^2-(1.8)^2)/(2*[g]))))^2.

FAQ

What is Venturi Head given Theoretical Discharge through Pipe?
The Venturi Head given Theoretical Discharge through Pipe formula is defined as the total head loss in the flow of fluid through pipe and is represented as hventuri = ((Qth/(Ai*Af))*(sqrt(((Ai)^2-(Af)^2)/(2*[g]))))^2 or Venturi Head = ((Theoretical Discharge/(Cross Section Area 1*Cross Section Area 2))*(sqrt(((Cross Section Area 1)^2-(Cross Section Area 2)^2)/(2*[g]))))^2. The Theoretical Discharge refers to the ideal flow rate of a fluid through a system, calculated under perfect conditions without considering any real-world losses like friction or turbulence, The Cross Section Area 1 refers to the area of cross section at the inlet of the structure (venturi meter or pipe) & The Cross Section Area 2 refers to the area of cross-section at the throat (venturi meter) of the structure.
How to calculate Venturi Head given Theoretical Discharge through Pipe?
The Venturi Head given Theoretical Discharge through Pipe formula is defined as the total head loss in the flow of fluid through pipe is calculated using Venturi Head = ((Theoretical Discharge/(Cross Section Area 1*Cross Section Area 2))*(sqrt(((Cross Section Area 1)^2-(Cross Section Area 2)^2)/(2*[g]))))^2. To calculate Venturi Head given Theoretical Discharge through Pipe, you need Theoretical Discharge (Qth), Cross Section Area 1 (Ai) & Cross Section Area 2 (Af). With our tool, you need to enter the respective value for Theoretical Discharge, Cross Section Area 1 & Cross Section Area 2 and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Venturi Head?
In this formula, Venturi Head uses Theoretical Discharge, Cross Section Area 1 & Cross Section Area 2. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Venturi Head = Length of Venturi meter*(Weight per unit Volume of Manometer Fluid/Specific Weight of Liquid-1)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!