Velocity while Running Partially Full given Proportionate Velocity Solution

STEP 0: Pre-Calculation Summary
Formula Used
Velocity in a Partially Running Sewer = Velocity While Running Full*Proportionate Velocity
Vs = V*Pv
This formula uses 3 Variables
Variables Used
Velocity in a Partially Running Sewer - (Measured in Meter per Second) - Velocity in a Partially Running Sewer is the speed of flow when the sewer isn't fully filled, influenced by depth and slope.
Velocity While Running Full - (Measured in Meter per Second) - Velocity while Running Full refers to the speed of fluid flow in a pipe when it's completely filled, influenced by pipe slope and roughness.
Proportionate Velocity - Proportionate Velocity is ratio of velocity when water is partially full to velocity when water is totally full.
STEP 1: Convert Input(s) to Base Unit
Velocity While Running Full: 6.01 Meter per Second --> 6.01 Meter per Second No Conversion Required
Proportionate Velocity: 0.765 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vs = V*Pv --> 6.01*0.765
Evaluating ... ...
Vs = 4.59765
STEP 3: Convert Result to Output's Unit
4.59765 Meter per Second --> No Conversion Required
FINAL ANSWER
4.59765 Meter per Second <-- Velocity in a Partially Running Sewer
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Circular Sewer Section Running Partially Full Calculators

Roughness Coefficient while Running Partially Full using Proportionate Velocity
​ LaTeX ​ Go Roughness Coefficient Partially Full = (Roughness Coefficient for Running Full/Proportionate Velocity)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(2/3)
Hydraulic Mean Depth while Running Partially Full given Proportionate Hydraulic Mean Depth
​ LaTeX ​ Go Hydraulic Mean Depth for Partially Full = Hydraulic Mean Depth while Running Full*Proportionate Hydraulic Mean Depth
Velocity while Running Partially Full given Proportionate Velocity
​ LaTeX ​ Go Velocity in a Partially Running Sewer = Velocity While Running Full*Proportionate Velocity
Area of Cross-section while Running Partially Full given Proportionate Area
​ LaTeX ​ Go Area of Partially Full Sewers = Proportionate Area*Area of Running Full Sewers

Velocity while Running Partially Full given Proportionate Velocity Formula

​LaTeX ​Go
Velocity in a Partially Running Sewer = Velocity While Running Full*Proportionate Velocity
Vs = V*Pv

What is Proportionate Velocity ?

Proportionate velocity for partially and fully running pipes is the ratio of the fluid velocity in a partially filled pipe to the velocity when the pipe is fully filled. This ratio is important for understanding how flow velocity changes with varying fluid levels, which impacts the efficiency of the system. It is crucial in the design and analysis of drainage, sewer, and water distribution systems, ensuring that the system functions effectively under different flow conditions.

How to Calculate Velocity while Running Partially Full given Proportionate Velocity?

Velocity while Running Partially Full given Proportionate Velocity calculator uses Velocity in a Partially Running Sewer = Velocity While Running Full*Proportionate Velocity to calculate the Velocity in a Partially Running Sewer, The Velocity while Running Partially Full given Proportionate Velocity is defined as the flow rate of fluid in a pipe when it is not fully filled, affected by depth and velocity. Velocity in a Partially Running Sewer is denoted by Vs symbol.

How to calculate Velocity while Running Partially Full given Proportionate Velocity using this online calculator? To use this online calculator for Velocity while Running Partially Full given Proportionate Velocity, enter Velocity While Running Full (V) & Proportionate Velocity (Pv) and hit the calculate button. Here is how the Velocity while Running Partially Full given Proportionate Velocity calculation can be explained with given input values -> 3.606 = 6.01*0.765.

FAQ

What is Velocity while Running Partially Full given Proportionate Velocity?
The Velocity while Running Partially Full given Proportionate Velocity is defined as the flow rate of fluid in a pipe when it is not fully filled, affected by depth and velocity and is represented as Vs = V*Pv or Velocity in a Partially Running Sewer = Velocity While Running Full*Proportionate Velocity. Velocity while Running Full refers to the speed of fluid flow in a pipe when it's completely filled, influenced by pipe slope and roughness & Proportionate Velocity is ratio of velocity when water is partially full to velocity when water is totally full.
How to calculate Velocity while Running Partially Full given Proportionate Velocity?
The Velocity while Running Partially Full given Proportionate Velocity is defined as the flow rate of fluid in a pipe when it is not fully filled, affected by depth and velocity is calculated using Velocity in a Partially Running Sewer = Velocity While Running Full*Proportionate Velocity. To calculate Velocity while Running Partially Full given Proportionate Velocity, you need Velocity While Running Full (V) & Proportionate Velocity (Pv). With our tool, you need to enter the respective value for Velocity While Running Full & Proportionate Velocity and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Velocity in a Partially Running Sewer?
In this formula, Velocity in a Partially Running Sewer uses Velocity While Running Full & Proportionate Velocity. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Velocity in a Partially Running Sewer = Discharge when Pipe is Running Partially Full/Area of Partially Full Sewers
  • Velocity in a Partially Running Sewer = (Proportionate Discharge*Velocity While Running Full*Area of Running Full Sewers)/Area of Partially Full Sewers
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!