Velocity of Full Flow given Hydraulic Mean Depth for Full Flow Solution

STEP 0: Pre-Calculation Summary
Formula Used
Velocity While Running Full = Velocity in a Partially Running Sewer/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(1/6))
V = Vs/((N/np)*(rpf/Rrf)^(1/6))
This formula uses 6 Variables
Variables Used
Velocity While Running Full - (Measured in Meter per Second) - Velocity while Running Full refers to the speed of fluid flow in a pipe when it's completely filled, influenced by pipe slope and roughness.
Velocity in a Partially Running Sewer - (Measured in Meter per Second) - Velocity in a Partially Running Sewer is the speed of flow when the sewer isn't fully filled, influenced by depth and slope.
Roughness Coefficient for Running Full - The Roughness Coefficient for Running Full accounts for uniform surface resistance affecting flow velocity and friction loss.
Roughness Coefficient Partially Full - Roughness Coefficient Partially Full means roughness coefficient of pipe while running partially full.
Hydraulic Mean Depth for Partially Full - (Measured in Meter) - Hydraulic Mean Depth for Partially Full refers to the cross-sectional area of flow divided by the wetted perimeter, adapting to varying water levels.
Hydraulic Mean Depth while Running Full - (Measured in Meter) - Hydraulic Mean Depth while Running Full refers to the ratio of the pipe's full cross-sectional area to its full wetted perimeter.
STEP 1: Convert Input(s) to Base Unit
Velocity in a Partially Running Sewer: 4.6 Meter per Second --> 4.6 Meter per Second No Conversion Required
Roughness Coefficient for Running Full: 0.74 --> No Conversion Required
Roughness Coefficient Partially Full: 0.9 --> No Conversion Required
Hydraulic Mean Depth for Partially Full: 3.2 Meter --> 3.2 Meter No Conversion Required
Hydraulic Mean Depth while Running Full: 5.2 Meter --> 5.2 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
V = Vs/((N/np)*(rpf/Rrf)^(1/6)) --> 4.6/((0.74/0.9)*(3.2/5.2)^(1/6))
Evaluating ... ...
V = 6.06611792813954
STEP 3: Convert Result to Output's Unit
6.06611792813954 Meter per Second --> No Conversion Required
FINAL ANSWER
6.06611792813954 6.066118 Meter per Second <-- Velocity While Running Full
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Flow Velocity through Circular Sewer Calculators

Self Cleansing Velocity using Ratio of Bed Slope
​ LaTeX ​ Go Velocity in a Partially Running Sewer = Velocity While Running Full*((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(2/3)*sqrt(Bed Slope Ratio))
Velocity Ratio given Ratio of Bed Slope
​ LaTeX ​ Go Velocity Ratio = (Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(2/3)*sqrt(Bed Slope Ratio)
Self Cleansing Velocity given Hydraulic Mean Depth Ratio
​ LaTeX ​ Go Velocity in a Partially Running Sewer = Velocity While Running Full*(Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth Ratio)^(1/6)
Velocity Ratio given Hydraulic Mean Depth Ratio
​ LaTeX ​ Go Velocity Ratio = ((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth Ratio)^(1/6))

Velocity of Full Flow given Hydraulic Mean Depth for Full Flow Formula

​LaTeX ​Go
Velocity While Running Full = Velocity in a Partially Running Sewer/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(1/6))
V = Vs/((N/np)*(rpf/Rrf)^(1/6))

What is Self-Cleansing Velocity?

The criterion for self-cleansing was defined as the minimum velocity needed to prevent the formation of separated dunes in the pipes. For a given sediment concentration the self-cleansing velocity was found to be a maximum at pipe slopes between about 30° and 37.5°.

How to Calculate Velocity of Full Flow given Hydraulic Mean Depth for Full Flow?

Velocity of Full Flow given Hydraulic Mean Depth for Full Flow calculator uses Velocity While Running Full = Velocity in a Partially Running Sewer/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(1/6)) to calculate the Velocity While Running Full, Velocity of Full Flow given Hydraulic Mean Depth for Full Flow is defined as the speed of fluid flow in a pipe when it's completely filled, influenced by pipe slope and roughness. Velocity While Running Full is denoted by V symbol.

How to calculate Velocity of Full Flow given Hydraulic Mean Depth for Full Flow using this online calculator? To use this online calculator for Velocity of Full Flow given Hydraulic Mean Depth for Full Flow, enter Velocity in a Partially Running Sewer (Vs), Roughness Coefficient for Running Full (N), Roughness Coefficient Partially Full (np), Hydraulic Mean Depth for Partially Full (rpf) & Hydraulic Mean Depth while Running Full (Rrf) and hit the calculate button. Here is how the Velocity of Full Flow given Hydraulic Mean Depth for Full Flow calculation can be explained with given input values -> 2.637443 = self_cleansing_velocity/((0.74/0.9)*(3.2/5.2)^(1/6)).

FAQ

What is Velocity of Full Flow given Hydraulic Mean Depth for Full Flow?
Velocity of Full Flow given Hydraulic Mean Depth for Full Flow is defined as the speed of fluid flow in a pipe when it's completely filled, influenced by pipe slope and roughness and is represented as V = Vs/((N/np)*(rpf/Rrf)^(1/6)) or Velocity While Running Full = Velocity in a Partially Running Sewer/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(1/6)). Velocity in a Partially Running Sewer is the speed of flow when the sewer isn't fully filled, influenced by depth and slope, The Roughness Coefficient for Running Full accounts for uniform surface resistance affecting flow velocity and friction loss, Roughness Coefficient Partially Full means roughness coefficient of pipe while running partially full, Hydraulic Mean Depth for Partially Full refers to the cross-sectional area of flow divided by the wetted perimeter, adapting to varying water levels & Hydraulic Mean Depth while Running Full refers to the ratio of the pipe's full cross-sectional area to its full wetted perimeter.
How to calculate Velocity of Full Flow given Hydraulic Mean Depth for Full Flow?
Velocity of Full Flow given Hydraulic Mean Depth for Full Flow is defined as the speed of fluid flow in a pipe when it's completely filled, influenced by pipe slope and roughness is calculated using Velocity While Running Full = Velocity in a Partially Running Sewer/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(1/6)). To calculate Velocity of Full Flow given Hydraulic Mean Depth for Full Flow, you need Velocity in a Partially Running Sewer (Vs), Roughness Coefficient for Running Full (N), Roughness Coefficient Partially Full (np), Hydraulic Mean Depth for Partially Full (rpf) & Hydraulic Mean Depth while Running Full (Rrf). With our tool, you need to enter the respective value for Velocity in a Partially Running Sewer, Roughness Coefficient for Running Full, Roughness Coefficient Partially Full, Hydraulic Mean Depth for Partially Full & Hydraulic Mean Depth while Running Full and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Velocity While Running Full?
In this formula, Velocity While Running Full uses Velocity in a Partially Running Sewer, Roughness Coefficient for Running Full, Roughness Coefficient Partially Full, Hydraulic Mean Depth for Partially Full & Hydraulic Mean Depth while Running Full. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Velocity While Running Full = Velocity in a Partially Running Sewer/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth Ratio)^(1/6))
  • Velocity While Running Full = Velocity in a Partially Running Sewer/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(2/3)*sqrt(Bed Slope Ratio))
  • Velocity While Running Full = Velocity in a Partially Running Sewer/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(2/3)*sqrt(Bed Slope of Partial Flow/Bed Slope of Channel))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!