Velocity of Flow of Water given Total Tension in Pipe Solution

STEP 0: Pre-Calculation Summary
Formula Used
Velocity of Flowing Water = sqrt((Total Tension in Pipe in KN-(Water Pressure in KN per Square Meter*Cross-Sectional Area))*([g]/(Unit Weight of Water in KN per Cubic Meter*Cross-Sectional Area)))
Vfw = sqrt((Ttkn-(Pwt*Acs))*([g]/(γwater*Acs)))
This formula uses 1 Constants, 1 Functions, 5 Variables
Constants Used
[g] - Gravitational acceleration on Earth Value Taken As 9.80665
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Velocity of Flowing Water - (Measured in Meter per Second) - Velocity of Flowing Water gives the velocity of an element of fluid at a position and time.
Total Tension in Pipe in KN - (Measured in Newton) - Total Tension in Pipe in KN is defined as the force that tries to elongate a pipe in KN.
Water Pressure in KN per Square Meter - (Measured in Pascal) - Water Pressure in KN per Square Meter is a force that makes a flow of water strong or weak.
Cross-Sectional Area - (Measured in Square Meter) - Cross-Sectional Area is the area of a two-dimensional shape that is obtained when a three-dimensional shape is sliced perpendicular to some specified axis at a point.
Unit Weight of Water in KN per Cubic Meter - (Measured in Newton per Cubic Meter) - Unit Weight of Water in KN per Cubic Meter is the weight of water per unit volume of water.
STEP 1: Convert Input(s) to Base Unit
Total Tension in Pipe in KN: 482.7 Kilonewton --> 482700 Newton (Check conversion ​here)
Water Pressure in KN per Square Meter: 4.97 Kilonewton per Square Meter --> 4970 Pascal (Check conversion ​here)
Cross-Sectional Area: 13 Square Meter --> 13 Square Meter No Conversion Required
Unit Weight of Water in KN per Cubic Meter: 9.81 Kilonewton per Cubic Meter --> 9810 Newton per Cubic Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vfw = sqrt((Ttkn-(Pwt*Acs))*([g]/(γwater*Acs))) --> sqrt((482700-(4970*13))*([g]/(9810*13)))
Evaluating ... ...
Vfw = 5.67007819214947
STEP 3: Convert Result to Output's Unit
5.67007819214947 Meter per Second --> No Conversion Required
FINAL ANSWER
5.67007819214947 5.670078 Meter per Second <-- Velocity of Flowing Water
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Stresses at Bends Calculators

Buttress Resistance using Head of Water
​ LaTeX ​ Go Buttress Resistance in Pipe = ((2*Cross-Sectional Area)*(((Unit Weight of Water in KN per Cubic Meter*(Velocity of Flowing Water^2))/[g])+(Unit Weight of Water in KN per Cubic Meter*Head of the Liquid))*sin((Angle of Bend in Environmental Engi.)/(2)))
Angle of Bend given Head of Water and Buttress Resistance
​ LaTeX ​ Go Angle of Bend in Environmental Engi. = 2*asin(Buttress Resistance in Pipe/((2*Cross-Sectional Area)*(((Unit Weight of Water in KN per Cubic Meter*(Flow Velocity of Fluid)^2)/[g])+(Unit Weight of Water in KN per Cubic Meter*Head of Liquid in Pipe))))
Buttress Resistance using Angle of Bend
​ LaTeX ​ Go Buttress Resistance in Pipe = (2*Cross-Sectional Area)*(((Unit Weight of Water in KN per Cubic Meter*((Velocity of Flowing Water^2)/[g]))+Internal Water Pressure in Pipes)*sin((Angle of Bend in Environmental Engi.)/(2)))
Angle of Bend given Buttress Resistance
​ LaTeX ​ Go Angle of Bend in Environmental Engi. = 2*asin(Buttress Resistance in Pipe/((2*Cross-Sectional Area)*(((Unit Weight of Water in KN per Cubic Meter*(Flow Velocity of Fluid)^2)/[g])+Water Pressure in KN per Square Meter)))

Velocity of Flow of Water given Total Tension in Pipe Formula

​LaTeX ​Go
Velocity of Flowing Water = sqrt((Total Tension in Pipe in KN-(Water Pressure in KN per Square Meter*Cross-Sectional Area))*([g]/(Unit Weight of Water in KN per Cubic Meter*Cross-Sectional Area)))
Vfw = sqrt((Ttkn-(Pwt*Acs))*([g]/(γwater*Acs)))

What is Velocity?

The flow velocity in fluid dynamics, also macroscopic velocity in statistical mechanics, or drift velocity in electromagnetism, is a vector field used to mathematically describe the motion of a continuum. The length of the flow velocity vector is the flow speed and is a scalar.

How to Calculate Velocity of Flow of Water given Total Tension in Pipe?

Velocity of Flow of Water given Total Tension in Pipe calculator uses Velocity of Flowing Water = sqrt((Total Tension in Pipe in KN-(Water Pressure in KN per Square Meter*Cross-Sectional Area))*([g]/(Unit Weight of Water in KN per Cubic Meter*Cross-Sectional Area))) to calculate the Velocity of Flowing Water, The Velocity of Flow of Water given Total Tension in Pipe formula is defined as the value of velocity of flow of water, considering total tension in pipe. Velocity of Flowing Water is denoted by Vfw symbol.

How to calculate Velocity of Flow of Water given Total Tension in Pipe using this online calculator? To use this online calculator for Velocity of Flow of Water given Total Tension in Pipe, enter Total Tension in Pipe in KN (Ttkn), Water Pressure in KN per Square Meter (Pwt), Cross-Sectional Area (Acs) & Unit Weight of Water in KN per Cubic Meter water) and hit the calculate button. Here is how the Velocity of Flow of Water given Total Tension in Pipe calculation can be explained with given input values -> 5.670078 = sqrt((482700-(4970*13))*([g]/(9810*13))).

FAQ

What is Velocity of Flow of Water given Total Tension in Pipe?
The Velocity of Flow of Water given Total Tension in Pipe formula is defined as the value of velocity of flow of water, considering total tension in pipe and is represented as Vfw = sqrt((Ttkn-(Pwt*Acs))*([g]/(γwater*Acs))) or Velocity of Flowing Water = sqrt((Total Tension in Pipe in KN-(Water Pressure in KN per Square Meter*Cross-Sectional Area))*([g]/(Unit Weight of Water in KN per Cubic Meter*Cross-Sectional Area))). Total Tension in Pipe in KN is defined as the force that tries to elongate a pipe in KN, Water Pressure in KN per Square Meter is a force that makes a flow of water strong or weak, Cross-Sectional Area is the area of a two-dimensional shape that is obtained when a three-dimensional shape is sliced perpendicular to some specified axis at a point & Unit Weight of Water in KN per Cubic Meter is the weight of water per unit volume of water.
How to calculate Velocity of Flow of Water given Total Tension in Pipe?
The Velocity of Flow of Water given Total Tension in Pipe formula is defined as the value of velocity of flow of water, considering total tension in pipe is calculated using Velocity of Flowing Water = sqrt((Total Tension in Pipe in KN-(Water Pressure in KN per Square Meter*Cross-Sectional Area))*([g]/(Unit Weight of Water in KN per Cubic Meter*Cross-Sectional Area))). To calculate Velocity of Flow of Water given Total Tension in Pipe, you need Total Tension in Pipe in KN (Ttkn), Water Pressure in KN per Square Meter (Pwt), Cross-Sectional Area (Acs) & Unit Weight of Water in KN per Cubic Meter water). With our tool, you need to enter the respective value for Total Tension in Pipe in KN, Water Pressure in KN per Square Meter, Cross-Sectional Area & Unit Weight of Water in KN per Cubic Meter and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Velocity of Flowing Water?
In this formula, Velocity of Flowing Water uses Total Tension in Pipe in KN, Water Pressure in KN per Square Meter, Cross-Sectional Area & Unit Weight of Water in KN per Cubic Meter. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Velocity of Flowing Water = sqrt((Buttress Resistance in Pipe/((2*Cross-Sectional Area)*sin((Angle of Bend in Environmental Engi.)/(2)))-Internal Water Pressure in Pipes)*([g]/Unit Weight of Water in KN per Cubic Meter))
  • Velocity of Flowing Water = (([g]/Unit Weight of Water in KN per Cubic Meter)*((Buttress Resistance in Pipe/(2*Cross-Sectional Area*sin((Angle of Bend in Environmental Engi.)/(2)))-Head of the Liquid*Unit Weight of Water in KN per Cubic Meter)))