Unloaded Q-factor Solution

STEP 0: Pre-Calculation Summary
Formula Used
Unloaded Q-factor = Capacitance at Vane Tips*Angular Frequency/Conductance of Cavity
Qun = Cv*ω/G
This formula uses 4 Variables
Variables Used
Unloaded Q-factor - Unloaded Q-factor is defined as a dimensionless parameter that describes how underdamped an oscillator or resonator is.
Capacitance at Vane Tips - (Measured in Farad) - Capacitance at Vane Tips is defined as the ratio of the amount of electric charge stored on a conductor to a difference in electric potential at the vane tips.
Angular Frequency - (Measured in Radian per Second) - Angular Frequency of a steadily recurring phenomenon expressed in radians per second.
Conductance of Cavity - (Measured in Siemens) - Conductance of Cavity can be expressed as the ratio of the current flowing through the cavity to the voltage across it. It is typically measured in units of siemens (S).
STEP 1: Convert Input(s) to Base Unit
Capacitance at Vane Tips: 2.5 Picofarad --> 2.5E-12 Farad (Check conversion ​here)
Angular Frequency: 790000000 Radian per Second --> 790000000 Radian per Second No Conversion Required
Conductance of Cavity: 1.4E-05 Siemens --> 1.4E-05 Siemens No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Qun = Cv*ω/G --> 2.5E-12*790000000/1.4E-05
Evaluating ... ...
Qun = 141.071428571429
STEP 3: Convert Result to Output's Unit
141.071428571429 --> No Conversion Required
FINAL ANSWER
141.071428571429 141.0714 <-- Unloaded Q-factor
(Calculation completed in 00.006 seconds)

Credits

Creator Image
Created by Shobhit Dimri
Bipin Tripathi Kumaon Institute of Technology (BTKIT), Dwarahat
Shobhit Dimri has created this Calculator and 900+ more calculators!
Verifier Image
Verified by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has verified this Calculator and 1900+ more calculators!

Q Factor Calculators

Q-Factor of Loaded Catcher Cavity
​ LaTeX ​ Go Q Factor of Loaded Catcher Cavity = (1/Q Factor of Catcher Wall)+(1/Q Factor of Beam Loading)+(1/Q Factor of External Load)
Q-Factor of Catcher Wall
​ LaTeX ​ Go Q Factor of Catcher Wall = 1/(Q Factor of Loaded Catcher Cavity-(1/Q Factor of Beam Loading)-(1/Q Factor of External Load))
Q-Factor of Beam Loading
​ LaTeX ​ Go Q Factor of Beam Loading = 1/(Q Factor of Loaded Catcher Cavity-(1/Q Factor of Catcher Wall)-(1/Q Factor of External Load))
Quality Factor of Cavity Resonator
​ LaTeX ​ Go Q factor of Cavity Resonator = Resonant Frequency/(Frequency 2-Frequency 1)

Unloaded Q-factor Formula

​LaTeX ​Go
Unloaded Q-factor = Capacitance at Vane Tips*Angular Frequency/Conductance of Cavity
Qun = Cv*ω/G

What is significance of Unloaded Q-factor?

Understanding and controlling the unloaded Q-factor is essential in designing resonant circuits for specific applications. Engineers often optimize the Q-factor based on the requirements of a particular system, balancing considerations such as selectivity, bandwidth, and efficiency.

How to Calculate Unloaded Q-factor?

Unloaded Q-factor calculator uses Unloaded Q-factor = Capacitance at Vane Tips*Angular Frequency/Conductance of Cavity to calculate the Unloaded Q-factor, The Unloaded Q-factor formula is defined as dimensionless parameter that describes how underdamped an oscillator or resonator is. It is approximately defined as the ratio of the initial energy stored in the resonator to the energy lost in one radian of the cycle of oscillation. Unloaded Q-factor is denoted by Qun symbol.

How to calculate Unloaded Q-factor using this online calculator? To use this online calculator for Unloaded Q-factor, enter Capacitance at Vane Tips (Cv), Angular Frequency (ω) & Conductance of Cavity (G) and hit the calculate button. Here is how the Unloaded Q-factor calculation can be explained with given input values -> 141.0714 = 2.5E-12*790000000/1.4E-05.

FAQ

What is Unloaded Q-factor?
The Unloaded Q-factor formula is defined as dimensionless parameter that describes how underdamped an oscillator or resonator is. It is approximately defined as the ratio of the initial energy stored in the resonator to the energy lost in one radian of the cycle of oscillation and is represented as Qun = Cv*ω/G or Unloaded Q-factor = Capacitance at Vane Tips*Angular Frequency/Conductance of Cavity. Capacitance at Vane Tips is defined as the ratio of the amount of electric charge stored on a conductor to a difference in electric potential at the vane tips, Angular Frequency of a steadily recurring phenomenon expressed in radians per second & Conductance of Cavity can be expressed as the ratio of the current flowing through the cavity to the voltage across it. It is typically measured in units of siemens (S).
How to calculate Unloaded Q-factor?
The Unloaded Q-factor formula is defined as dimensionless parameter that describes how underdamped an oscillator or resonator is. It is approximately defined as the ratio of the initial energy stored in the resonator to the energy lost in one radian of the cycle of oscillation is calculated using Unloaded Q-factor = Capacitance at Vane Tips*Angular Frequency/Conductance of Cavity. To calculate Unloaded Q-factor, you need Capacitance at Vane Tips (Cv), Angular Frequency (ω) & Conductance of Cavity (G). With our tool, you need to enter the respective value for Capacitance at Vane Tips, Angular Frequency & Conductance of Cavity and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!