Unknown Resistance in Maxwell Inductance Bridge Solution

STEP 0: Pre-Calculation Summary
Formula Used
Unknown Resistance in Maxwell Bridge = (Known Resistance 3 in Maxwell Bridge/Known Resistance 4 in Maxwell Bridge)*(Variable Resistance in Maxwell Bridge+Decade Resistance in Maxwell Bridge)
R1(max) = (R3(max)/R4(max))*(R2(max)+r2(max))
This formula uses 5 Variables
Variables Used
Unknown Resistance in Maxwell Bridge - (Measured in Ohm) - Unknown Resistance in Maxwell Bridge refers to the resistor whose value is to be measured.
Known Resistance 3 in Maxwell Bridge - (Measured in Ohm) - Known Resistance 3 in Maxwell Bridge refers to the resistors in the bridge circuit whose values are precisely known and used as reference elements. It is an non inductive resistance.
Known Resistance 4 in Maxwell Bridge - (Measured in Ohm) - Known Resistance 4 in Maxwell Bridge refers to the resistors in the bridge circuit whose values are precisely known and used as reference elements. It is an non inductive resistance.
Variable Resistance in Maxwell Bridge - (Measured in Ohm) - Variable Resistance in Maxwell Bridge refers to a resistor whose value can be adjusted or varied to achieve balance in the bridge circuit.
Decade Resistance in Maxwell Bridge - (Measured in Ohm) - Decade Resistance in Maxwell Bridge is a precision instrument used in electrical and electronic circuits for creating specific resistance values with a high degree of accuracy.
STEP 1: Convert Input(s) to Base Unit
Known Resistance 3 in Maxwell Bridge: 12 Ohm --> 12 Ohm No Conversion Required
Known Resistance 4 in Maxwell Bridge: 14 Ohm --> 14 Ohm No Conversion Required
Variable Resistance in Maxwell Bridge: 29 Ohm --> 29 Ohm No Conversion Required
Decade Resistance in Maxwell Bridge: 100 Ohm --> 100 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
R1(max) = (R3(max)/R4(max))*(R2(max)+r2(max)) --> (12/14)*(29+100)
Evaluating ... ...
R1(max) = 110.571428571429
STEP 3: Convert Result to Output's Unit
110.571428571429 Ohm --> No Conversion Required
FINAL ANSWER
110.571428571429 110.5714 Ohm <-- Unknown Resistance in Maxwell Bridge
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Nikita Suryawanshi
Vellore Institute of Technology (VIT), Vellore
Nikita Suryawanshi has created this Calculator and 100+ more calculators!
Verifier Image
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

Maxwell Bridge Calculators

Unknown Resistance in Maxwell Inductance Bridge
​ LaTeX ​ Go Unknown Resistance in Maxwell Bridge = (Known Resistance 3 in Maxwell Bridge/Known Resistance 4 in Maxwell Bridge)*(Variable Resistance in Maxwell Bridge+Decade Resistance in Maxwell Bridge)
Unknown Inductance in Maxwell Inductance Bridge
​ LaTeX ​ Go Unknown Inductance in Maxwell Bridge = (Known Resistance 3 in Maxwell Bridge/Known Resistance 4 in Maxwell Bridge)*Variable Inductance in Maxwell Bridge
Iron Loss in Maxwell Bridge
​ LaTeX ​ Go Iron Loss in Maxwell Bridge = Current 1 in Maxwell Bridge^2*(Effective Resistance in Maxwell Bridge-Coil Winding Resistance in Maxwell Bridge)
Quality Factor of Maxwell Inductance-Capacitance Bridge
​ LaTeX ​ Go Quality Factor in Maxwell Bridge = (Angular Frequency*Unknown Inductance in Maxwell Bridge)/Effective Resistance in Maxwell Bridge

Unknown Resistance in Maxwell Inductance Bridge Formula

​LaTeX ​Go
Unknown Resistance in Maxwell Bridge = (Known Resistance 3 in Maxwell Bridge/Known Resistance 4 in Maxwell Bridge)*(Variable Resistance in Maxwell Bridge+Decade Resistance in Maxwell Bridge)
R1(max) = (R3(max)/R4(max))*(R2(max)+r2(max))

What are the advantages of measuring the resistance through Maxwell's Bridge?

Measuring the resistance through Maxwell's Bridge offers several advantages, including its ability to provide accurate and precise readings, its simplicity in design and implementation, and its ability to measure very small impedances, including those in the range of milliohms. Additionally, the bridge circuit can measure the resistance of a component regardless of its polarity, making it a versatile tool for a wide range of applications.

How to Calculate Unknown Resistance in Maxwell Inductance Bridge?

Unknown Resistance in Maxwell Inductance Bridge calculator uses Unknown Resistance in Maxwell Bridge = (Known Resistance 3 in Maxwell Bridge/Known Resistance 4 in Maxwell Bridge)*(Variable Resistance in Maxwell Bridge+Decade Resistance in Maxwell Bridge) to calculate the Unknown Resistance in Maxwell Bridge, Unknown Resistance in Maxwell Inductance Bridge formula refers to the inductor whose value is to be measured. The Maxwell Bridge is a type of bridge circuit that is specifically designed to determine the value of an unknown inductor accurately by achieving balance in the bridge circuit and comparing the ratios of impedances. Unknown Resistance in Maxwell Bridge is denoted by R1(max) symbol.

How to calculate Unknown Resistance in Maxwell Inductance Bridge using this online calculator? To use this online calculator for Unknown Resistance in Maxwell Inductance Bridge, enter Known Resistance 3 in Maxwell Bridge (R3(max)), Known Resistance 4 in Maxwell Bridge (R4(max)), Variable Resistance in Maxwell Bridge (R2(max)) & Decade Resistance in Maxwell Bridge (r2(max)) and hit the calculate button. Here is how the Unknown Resistance in Maxwell Inductance Bridge calculation can be explained with given input values -> 110.5714 = (12/14)*(29+100).

FAQ

What is Unknown Resistance in Maxwell Inductance Bridge?
Unknown Resistance in Maxwell Inductance Bridge formula refers to the inductor whose value is to be measured. The Maxwell Bridge is a type of bridge circuit that is specifically designed to determine the value of an unknown inductor accurately by achieving balance in the bridge circuit and comparing the ratios of impedances and is represented as R1(max) = (R3(max)/R4(max))*(R2(max)+r2(max)) or Unknown Resistance in Maxwell Bridge = (Known Resistance 3 in Maxwell Bridge/Known Resistance 4 in Maxwell Bridge)*(Variable Resistance in Maxwell Bridge+Decade Resistance in Maxwell Bridge). Known Resistance 3 in Maxwell Bridge refers to the resistors in the bridge circuit whose values are precisely known and used as reference elements. It is an non inductive resistance, Known Resistance 4 in Maxwell Bridge refers to the resistors in the bridge circuit whose values are precisely known and used as reference elements. It is an non inductive resistance, Variable Resistance in Maxwell Bridge refers to a resistor whose value can be adjusted or varied to achieve balance in the bridge circuit & Decade Resistance in Maxwell Bridge is a precision instrument used in electrical and electronic circuits for creating specific resistance values with a high degree of accuracy.
How to calculate Unknown Resistance in Maxwell Inductance Bridge?
Unknown Resistance in Maxwell Inductance Bridge formula refers to the inductor whose value is to be measured. The Maxwell Bridge is a type of bridge circuit that is specifically designed to determine the value of an unknown inductor accurately by achieving balance in the bridge circuit and comparing the ratios of impedances is calculated using Unknown Resistance in Maxwell Bridge = (Known Resistance 3 in Maxwell Bridge/Known Resistance 4 in Maxwell Bridge)*(Variable Resistance in Maxwell Bridge+Decade Resistance in Maxwell Bridge). To calculate Unknown Resistance in Maxwell Inductance Bridge, you need Known Resistance 3 in Maxwell Bridge (R3(max)), Known Resistance 4 in Maxwell Bridge (R4(max)), Variable Resistance in Maxwell Bridge (R2(max)) & Decade Resistance in Maxwell Bridge (r2(max)). With our tool, you need to enter the respective value for Known Resistance 3 in Maxwell Bridge, Known Resistance 4 in Maxwell Bridge, Variable Resistance in Maxwell Bridge & Decade Resistance in Maxwell Bridge and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!