Ultimate Load per Area for Aluminium Columns given Allowable Load and Section Area Solution

STEP 0: Pre-Calculation Summary
Formula Used
Ultimate Load = (1.95*(Allowable Load/Section Area of Column))*Section Area of Column
P = (1.95*(Q/A))*A
This formula uses 3 Variables
Variables Used
Ultimate Load - (Measured in Newton) - The Ultimate Load is a statistical figure used in calculations and should (hopefully) never actually occur. Strength requirements are specified in terms of limit loads and ultimate loads.
Allowable Load - (Measured in Newton) - The Allowable Load is the maximum working load that can be applied on the structure.
Section Area of Column - (Measured in Square Meter) - The Section Area of Column is the area of a two-dimensional shape that is obtained when a three-dimensional shape is sliced perpendicular to some specified axis at a point.
STEP 1: Convert Input(s) to Base Unit
Allowable Load: 633.213 Newton --> 633.213 Newton No Conversion Required
Section Area of Column: 52900 Square Millimeter --> 0.0529 Square Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
P = (1.95*(Q/A))*A --> (1.95*(633.213/0.0529))*0.0529
Evaluating ... ...
P = 1234.76535
STEP 3: Convert Result to Output's Unit
1234.76535 Newton --> No Conversion Required
FINAL ANSWER
1234.76535 1234.765 Newton <-- Ultimate Load
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Rudrani Tidke
Cummins College of Engineering for Women (CCEW), Pune
Rudrani Tidke has created this Calculator and 100+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Aluminium Column Design Calculators

Ultimate Load per Area for Aluminium Columns given Allowable Load and Section Area
​ LaTeX ​ Go Ultimate Load = (1.95*(Allowable Load/Section Area of Column))*Section Area of Column
Critical Slenderness Ratio for Aluminium Columns
​ LaTeX ​ Go Slenderness Ratio = sqrt(51000000/(Allowable Load/Section Area of Column))
Ultimate Load per Area for Aluminium Columns
​ LaTeX ​ Go Ultimate Load = (34000-88*Slenderness Ratio)*Section Area of Column

Ultimate Load per Area for Aluminium Columns given Allowable Load and Section Area Formula

​LaTeX ​Go
Ultimate Load = (1.95*(Allowable Load/Section Area of Column))*Section Area of Column
P = (1.95*(Q/A))*A

What is the difference between Ultimate Load and Allowable Load?

Under the Allowable Stress Design (ASD) method, the allowable load is based on the application of a safety factor to the mean result of laboratory testing to failure, regardless of the controlling failure mode observed in the tests.
the ultimate load is a statistical figure used in calculations and should (hopefully) never actually occur.
Strength requirements are specified in terms of limit loads (the maximum loads to be expected in service) and ultimate loads (limit loads multiplied by prescribed factors of safety).

Define Slenderness Ratio.

It is used extensively for finding out the design load as well as in classifying various columns in short/intermediate/long. The slenderness ratio of a column gives an indication of buckling failure in the column. The more the slenderness ratio, more the tendency of a column to fail by buckling effect in that direction.

How to Calculate Ultimate Load per Area for Aluminium Columns given Allowable Load and Section Area?

Ultimate Load per Area for Aluminium Columns given Allowable Load and Section Area calculator uses Ultimate Load = (1.95*(Allowable Load/Section Area of Column))*Section Area of Column to calculate the Ultimate Load, The Ultimate Load per Area for Aluminium Columns given Allowable Load and Section Area formula is defined as the Limit Load multiplied by a prescribed Safety Factor per unit cross-sectional area for aluminium columns. Ultimate Load is denoted by P symbol.

How to calculate Ultimate Load per Area for Aluminium Columns given Allowable Load and Section Area using this online calculator? To use this online calculator for Ultimate Load per Area for Aluminium Columns given Allowable Load and Section Area, enter Allowable Load (Q) & Section Area of Column (A) and hit the calculate button. Here is how the Ultimate Load per Area for Aluminium Columns given Allowable Load and Section Area calculation can be explained with given input values -> 1234.765 = (1.95*(633.213/0.0529))*0.0529.

FAQ

What is Ultimate Load per Area for Aluminium Columns given Allowable Load and Section Area?
The Ultimate Load per Area for Aluminium Columns given Allowable Load and Section Area formula is defined as the Limit Load multiplied by a prescribed Safety Factor per unit cross-sectional area for aluminium columns and is represented as P = (1.95*(Q/A))*A or Ultimate Load = (1.95*(Allowable Load/Section Area of Column))*Section Area of Column. The Allowable Load is the maximum working load that can be applied on the structure & The Section Area of Column is the area of a two-dimensional shape that is obtained when a three-dimensional shape is sliced perpendicular to some specified axis at a point.
How to calculate Ultimate Load per Area for Aluminium Columns given Allowable Load and Section Area?
The Ultimate Load per Area for Aluminium Columns given Allowable Load and Section Area formula is defined as the Limit Load multiplied by a prescribed Safety Factor per unit cross-sectional area for aluminium columns is calculated using Ultimate Load = (1.95*(Allowable Load/Section Area of Column))*Section Area of Column. To calculate Ultimate Load per Area for Aluminium Columns given Allowable Load and Section Area, you need Allowable Load (Q) & Section Area of Column (A). With our tool, you need to enter the respective value for Allowable Load & Section Area of Column and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Ultimate Load?
In this formula, Ultimate Load uses Allowable Load & Section Area of Column. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Ultimate Load = (34000-88*Slenderness Ratio)*Section Area of Column