Treatability Constant at 30 degrees Celsius and 20 ft Filter Depth Solution

STEP 0: Pre-Calculation Summary
Formula Used
Treatability Constant at 30°C and 20ft Depth = Treatability Constant at 20°C and 20ft Depth*(Temperature Activity Coefficient)^(Wastewater Temperature-20)
K30/20 = K20/20*(θ)^(T-20)
This formula uses 4 Variables
Variables Used
Treatability Constant at 30°C and 20ft Depth - The Treatability Constant at 30°C and 20ft depth refers to a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 30°C at 20ft filter depth.
Treatability Constant at 20°C and 20ft Depth - The Treatability Constant at 20°C and 20ft Depth refers to a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 20°C at 20ft filter depth.
Temperature Activity Coefficient - The Temperature Activity Coefficient refers to a factor that adjusts reaction rates or biological activity in response to temperature changes, commonly used in biochemical processes.
Wastewater Temperature - (Measured in Kelvin) - The Wastewater Temperature refers to the measure of heat present in wastewater, affecting treatment efficiency and biological activity, typically measured in degrees Celsius (°C).
STEP 1: Convert Input(s) to Base Unit
Treatability Constant at 20°C and 20ft Depth: 0.002 --> No Conversion Required
Temperature Activity Coefficient: 1.035 --> No Conversion Required
Wastewater Temperature: 25 Celsius --> 298.15 Kelvin (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
K30/20 = K20/20*(θ)^(T-20) --> 0.002*(1.035)^(298.15-20)
Evaluating ... ...
K30/20 = 28.6212297956377
STEP 3: Convert Result to Output's Unit
28.6212297956377 --> No Conversion Required
FINAL ANSWER
28.6212297956377 28.62123 <-- Treatability Constant at 30°C and 20ft Depth
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

9 Treatability Constant Calculators

Empirical Constant given Treatability Constant
​ Go Empirical Constant = (ln(Treatability Constant at 30°C and 25ft Depth/Treatability Constant at 30°C and 20ft Depth)/ln(Depth of Reference Filter/Depth of Actual Filter))
Wastewater Temperature using Treatability Constant
​ Go Wastewater Temperature = 20+(ln(Treatability Constant at 30°C and 20ft Depth/Treatability Constant at 20°C and 20ft Depth)*(1/ln(Temperature Activity Coefficient)))
Depth of Reference Filter using Treatability Constant
​ Go Depth of Reference Filter = Depth of Actual Filter*(Treatability Constant at 30°C and 25ft Depth/Treatability Constant at 30°C and 20ft Depth)^(1/Empirical Constant)
Depth of Actual Filter using Treatability Constant
​ Go Depth of Actual Filter = Depth of Reference Filter*(Treatability Constant at 30°C and 20ft Depth/Treatability Constant at 30°C and 25ft Depth)^(1/Empirical Constant)
Treatability Constant at 30 degree Celsius and 25 ft Filter Depth
​ Go Treatability Constant at 30°C and 25ft Depth = Treatability Constant at 30°C and 20ft Depth*(Depth of Reference Filter/Depth of Actual Filter)^(Empirical Constant)
Treatability Constant at 30 degree Celsius and 20 ft Filter Depth
​ Go Treatability Constant at 30°C and 20ft Depth = Treatability Constant at 30°C and 25ft Depth*(Depth of Actual Filter/Depth of Reference Filter)^(Empirical Constant)
Temperature Activity Coefficient given Treatability Constant
​ Go Temperature Activity Coefficient = (Treatability Constant at 30°C and 20ft Depth/Treatability Constant at 20°C and 20ft Depth)^(1/(Wastewater Temperature-20))
Treatability Constant at 30 degrees Celsius and 20 ft Filter Depth
​ Go Treatability Constant at 30°C and 20ft Depth = Treatability Constant at 20°C and 20ft Depth*(Temperature Activity Coefficient)^(Wastewater Temperature-20)
Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth
​ Go Treatability Constant at 20°C and 20ft Depth = Treatability Constant at 30°C and 20ft Depth/(Temperature Activity Coefficient)^(Wastewater Temperature-20)

Treatability Constant at 30 degrees Celsius and 20 ft Filter Depth Formula

Treatability Constant at 30°C and 20ft Depth = Treatability Constant at 20°C and 20ft Depth*(Temperature Activity Coefficient)^(Wastewater Temperature-20)
K30/20 = K20/20*(θ)^(T-20)

What is Wastewater ?

Wastewater (or waste water) is any water that has been contaminated by human use. Wastewater is "used water from any combination of domestic, industrial, commercial or agricultural activities, surface runoff or stormwater, and any sewer inflow or sewer infiltration".

How to Calculate Treatability Constant at 30 degrees Celsius and 20 ft Filter Depth?

Treatability Constant at 30 degrees Celsius and 20 ft Filter Depth calculator uses Treatability Constant at 30°C and 20ft Depth = Treatability Constant at 20°C and 20ft Depth*(Temperature Activity Coefficient)^(Wastewater Temperature-20) to calculate the Treatability Constant at 30°C and 20ft Depth, The Treatability Constant at 30 degrees Celsius and 20 ft Filter Depth is defined as a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 30°C at 20ft filter depth. Treatability Constant at 30°C and 20ft Depth is denoted by K30/20 symbol.

How to calculate Treatability Constant at 30 degrees Celsius and 20 ft Filter Depth using this online calculator? To use this online calculator for Treatability Constant at 30 degrees Celsius and 20 ft Filter Depth, enter Treatability Constant at 20°C and 20ft Depth (K20/20), Temperature Activity Coefficient (θ) & Wastewater Temperature (T) and hit the calculate button. Here is how the Treatability Constant at 30 degrees Celsius and 20 ft Filter Depth calculation can be explained with given input values -> 28.62123 = 0.002*(1.035)^(298.15-20).

FAQ

What is Treatability Constant at 30 degrees Celsius and 20 ft Filter Depth?
The Treatability Constant at 30 degrees Celsius and 20 ft Filter Depth is defined as a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 30°C at 20ft filter depth and is represented as K30/20 = K20/20*(θ)^(T-20) or Treatability Constant at 30°C and 20ft Depth = Treatability Constant at 20°C and 20ft Depth*(Temperature Activity Coefficient)^(Wastewater Temperature-20). The Treatability Constant at 20°C and 20ft Depth refers to a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 20°C at 20ft filter depth, The Temperature Activity Coefficient refers to a factor that adjusts reaction rates or biological activity in response to temperature changes, commonly used in biochemical processes & The Wastewater Temperature refers to the measure of heat present in wastewater, affecting treatment efficiency and biological activity, typically measured in degrees Celsius (°C).
How to calculate Treatability Constant at 30 degrees Celsius and 20 ft Filter Depth?
The Treatability Constant at 30 degrees Celsius and 20 ft Filter Depth is defined as a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 30°C at 20ft filter depth is calculated using Treatability Constant at 30°C and 20ft Depth = Treatability Constant at 20°C and 20ft Depth*(Temperature Activity Coefficient)^(Wastewater Temperature-20). To calculate Treatability Constant at 30 degrees Celsius and 20 ft Filter Depth, you need Treatability Constant at 20°C and 20ft Depth (K20/20), Temperature Activity Coefficient (θ) & Wastewater Temperature (T). With our tool, you need to enter the respective value for Treatability Constant at 20°C and 20ft Depth, Temperature Activity Coefficient & Wastewater Temperature and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Treatability Constant at 30°C and 20ft Depth?
In this formula, Treatability Constant at 30°C and 20ft Depth uses Treatability Constant at 20°C and 20ft Depth, Temperature Activity Coefficient & Wastewater Temperature. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Treatability Constant at 30°C and 20ft Depth = Treatability Constant at 30°C and 25ft Depth*(Depth of Actual Filter/Depth of Reference Filter)^(Empirical Constant)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!