Treatability Constant at 30 degree Celsius and 25 ft Filter Depth Solution

STEP 0: Pre-Calculation Summary
Formula Used
Treatability Constant at 30°C and 25ft Depth = Treatability Constant at 30°C and 20ft Depth*(Depth of Reference Filter/Depth of Actual Filter)^(Empirical Constant)
K30/25 = K30/20*(D1/D2)^(a)
This formula uses 5 Variables
Variables Used
Treatability Constant at 30°C and 25ft Depth - The Treatability Constant at 30°C and 25ft depth refers to a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 30°C at 25ft filter depth.
Treatability Constant at 30°C and 20ft Depth - The Treatability Constant at 30°C and 20ft depth refers to a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 30°C at 20ft filter depth.
Depth of Reference Filter - (Measured in Meter) - The Depth of Reference Filter refers to the standard vertical distance used to compare filtration systems, typically measured in meters (m), to assess relative performance.
Depth of Actual Filter - (Measured in Meter) - The Depth of Actual Filter refers to the vertical distance from the top surface to the bottom of the filter media, impacting filtration efficiency, typically measured in meters (m).
Empirical Constant - The Empirical Constant refers to a value derived from experimental data and observations, used in equations to predict or describe phenomena within specific conditions.
STEP 1: Convert Input(s) to Base Unit
Treatability Constant at 30°C and 20ft Depth: 28.62 --> No Conversion Required
Depth of Reference Filter: 6.1 Meter --> 6.1 Meter No Conversion Required
Depth of Actual Filter: 7.6 Meter --> 7.6 Meter No Conversion Required
Empirical Constant: 0.3 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
K30/25 = K30/20*(D1/D2)^(a) --> 28.62*(6.1/7.6)^(0.3)
Evaluating ... ...
K30/25 = 26.7931948373826
STEP 3: Convert Result to Output's Unit
26.7931948373826 --> No Conversion Required
FINAL ANSWER
26.7931948373826 26.79319 <-- Treatability Constant at 30°C and 25ft Depth
(Calculation completed in 00.018 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Treatability Constant Calculators

Wastewater Temperature using Treatability Constant
​ LaTeX ​ Go Wastewater Temperature = 20+(ln(Treatability Constant at 30°C and 20ft Depth/Treatability Constant at 20°C and 20ft Depth)*(1/ln(Temperature Activity Coefficient)))
Temperature Activity Coefficient given Treatability Constant
​ LaTeX ​ Go Temperature Activity Coefficient = (Treatability Constant at 30°C and 20ft Depth/Treatability Constant at 20°C and 20ft Depth)^(1/(Wastewater Temperature-20))
Treatability Constant at 30 degrees Celsius and 20 ft Filter Depth
​ LaTeX ​ Go Treatability Constant at 30°C and 20ft Depth = Treatability Constant at 20°C and 20ft Depth*(Temperature Activity Coefficient)^(Wastewater Temperature-20)
Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth
​ LaTeX ​ Go Treatability Constant at 20°C and 20ft Depth = Treatability Constant at 30°C and 20ft Depth/(Temperature Activity Coefficient)^(Wastewater Temperature-20)

Treatability Constant at 30 degree Celsius and 25 ft Filter Depth Formula

​LaTeX ​Go
Treatability Constant at 30°C and 25ft Depth = Treatability Constant at 30°C and 20ft Depth*(Depth of Reference Filter/Depth of Actual Filter)^(Empirical Constant)
K30/25 = K30/20*(D1/D2)^(a)

What is Trickling Filter?

A trickling filter is a type of wastewater treatment system. It consists of a fixed bed of rocks, coke, gravel, slag, polyurethane foam, sphagnum peat moss, ceramic, or plastic media over which sewage or other wastewater flows downward and causes a layer of microbial slime to grow, covering the bed of media.

How to Calculate Treatability Constant at 30 degree Celsius and 25 ft Filter Depth?

Treatability Constant at 30 degree Celsius and 25 ft Filter Depth calculator uses Treatability Constant at 30°C and 25ft Depth = Treatability Constant at 30°C and 20ft Depth*(Depth of Reference Filter/Depth of Actual Filter)^(Empirical Constant) to calculate the Treatability Constant at 30°C and 25ft Depth, The Treatability Constant at 30 degree Celsius and 25 ft Filter Depth is defined as a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 30°C at 25ft filter depth. Treatability Constant at 30°C and 25ft Depth is denoted by K30/25 symbol.

How to calculate Treatability Constant at 30 degree Celsius and 25 ft Filter Depth using this online calculator? To use this online calculator for Treatability Constant at 30 degree Celsius and 25 ft Filter Depth, enter Treatability Constant at 30°C and 20ft Depth (K30/20), Depth of Reference Filter (D1), Depth of Actual Filter (D2) & Empirical Constant (a) and hit the calculate button. Here is how the Treatability Constant at 30 degree Celsius and 25 ft Filter Depth calculation can be explained with given input values -> 25.36025 = 28.62*(6.1/7.6)^(0.3).

FAQ

What is Treatability Constant at 30 degree Celsius and 25 ft Filter Depth?
The Treatability Constant at 30 degree Celsius and 25 ft Filter Depth is defined as a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 30°C at 25ft filter depth and is represented as K30/25 = K30/20*(D1/D2)^(a) or Treatability Constant at 30°C and 25ft Depth = Treatability Constant at 30°C and 20ft Depth*(Depth of Reference Filter/Depth of Actual Filter)^(Empirical Constant). The Treatability Constant at 30°C and 20ft depth refers to a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 30°C at 20ft filter depth, The Depth of Reference Filter refers to the standard vertical distance used to compare filtration systems, typically measured in meters (m), to assess relative performance, The Depth of Actual Filter refers to the vertical distance from the top surface to the bottom of the filter media, impacting filtration efficiency, typically measured in meters (m) & The Empirical Constant refers to a value derived from experimental data and observations, used in equations to predict or describe phenomena within specific conditions.
How to calculate Treatability Constant at 30 degree Celsius and 25 ft Filter Depth?
The Treatability Constant at 30 degree Celsius and 25 ft Filter Depth is defined as a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 30°C at 25ft filter depth is calculated using Treatability Constant at 30°C and 25ft Depth = Treatability Constant at 30°C and 20ft Depth*(Depth of Reference Filter/Depth of Actual Filter)^(Empirical Constant). To calculate Treatability Constant at 30 degree Celsius and 25 ft Filter Depth, you need Treatability Constant at 30°C and 20ft Depth (K30/20), Depth of Reference Filter (D1), Depth of Actual Filter (D2) & Empirical Constant (a). With our tool, you need to enter the respective value for Treatability Constant at 30°C and 20ft Depth, Depth of Reference Filter, Depth of Actual Filter & Empirical Constant and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!