Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth Solution

STEP 0: Pre-Calculation Summary
Formula Used
Treatability Constant at 20°C and 20ft Depth = Treatability Constant at 30°C and 20ft Depth/(Temperature Activity Coefficient)^(Wastewater Temperature-20)
K20/20 = K30/20/(θ)^(T-20)
This formula uses 4 Variables
Variables Used
Treatability Constant at 20°C and 20ft Depth - The Treatability Constant at 20°C and 20ft Depth refers to a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 20°C at 20ft filter depth.
Treatability Constant at 30°C and 20ft Depth - The Treatability Constant at 30°C and 20ft depth refers to a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 30°C at 20ft filter depth.
Temperature Activity Coefficient - The Temperature Activity Coefficient refers to a factor that adjusts reaction rates or biological activity in response to temperature changes, commonly used in biochemical processes.
Wastewater Temperature - (Measured in Kelvin) - The Wastewater Temperature refers to the measure of heat present in wastewater, affecting treatment efficiency and biological activity, typically measured in degrees Celsius (°C).
STEP 1: Convert Input(s) to Base Unit
Treatability Constant at 30°C and 20ft Depth: 28.62 --> No Conversion Required
Temperature Activity Coefficient: 1.035 --> No Conversion Required
Wastewater Temperature: 25 Celsius --> 298.15 Kelvin (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
K20/20 = K30/20/(θ)^(T-20) --> 28.62/(1.035)^(298.15-20)
Evaluating ... ...
K20/20 = 0.00199991406409532
STEP 3: Convert Result to Output's Unit
0.00199991406409532 --> No Conversion Required
FINAL ANSWER
0.00199991406409532 0.002 <-- Treatability Constant at 20°C and 20ft Depth
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Treatability Constant Calculators

Wastewater Temperature using Treatability Constant
​ Go Wastewater Temperature = 20+(ln(Treatability Constant at 30°C and 20ft Depth/Treatability Constant at 20°C and 20ft Depth)*(1/ln(Temperature Activity Coefficient)))
Temperature Activity Coefficient given Treatability Constant
​ Go Temperature Activity Coefficient = (Treatability Constant at 30°C and 20ft Depth/Treatability Constant at 20°C and 20ft Depth)^(1/(Wastewater Temperature-20))
Treatability Constant at 30 degrees Celsius and 20 ft Filter Depth
​ Go Treatability Constant at 30°C and 20ft Depth = Treatability Constant at 20°C and 20ft Depth*(Temperature Activity Coefficient)^(Wastewater Temperature-20)
Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth
​ Go Treatability Constant at 20°C and 20ft Depth = Treatability Constant at 30°C and 20ft Depth/(Temperature Activity Coefficient)^(Wastewater Temperature-20)

Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth Formula

Treatability Constant at 20°C and 20ft Depth = Treatability Constant at 30°C and 20ft Depth/(Temperature Activity Coefficient)^(Wastewater Temperature-20)
K20/20 = K30/20/(θ)^(T-20)

What is Trickling Filter ?

A Trickling Filter is a type of wastewater treatment system. It consists of a fixed bed of rocks, coke, gravel, slag, polyurethane foam, sphagnum peat moss, ceramic, or plastic media over which sewage or other wastewater flows downward and causes a layer of microbial slime (biofilm) to grow, covering the bed of media.

How to Calculate Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth?

Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth calculator uses Treatability Constant at 20°C and 20ft Depth = Treatability Constant at 30°C and 20ft Depth/(Temperature Activity Coefficient)^(Wastewater Temperature-20) to calculate the Treatability Constant at 20°C and 20ft Depth, The Treatability Constant at 20 degrees Celsius and 20 ft Filter Depth is defined as a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 20°C at 20ft filter depth. Treatability Constant at 20°C and 20ft Depth is denoted by K20/20 symbol.

How to calculate Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth using this online calculator? To use this online calculator for Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth, enter Treatability Constant at 30°C and 20ft Depth (K30/20), Temperature Activity Coefficient (θ) & Wastewater Temperature (T) and hit the calculate button. Here is how the Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth calculation can be explained with given input values -> 0.00014 = treatability_constant_at_30_20/(1.035)^(298.15-20).

FAQ

What is Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth?
The Treatability Constant at 20 degrees Celsius and 20 ft Filter Depth is defined as a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 20°C at 20ft filter depth and is represented as K20/20 = K30/20/(θ)^(T-20) or Treatability Constant at 20°C and 20ft Depth = Treatability Constant at 30°C and 20ft Depth/(Temperature Activity Coefficient)^(Wastewater Temperature-20). The Treatability Constant at 30°C and 20ft depth refers to a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 30°C at 20ft filter depth, The Temperature Activity Coefficient refers to a factor that adjusts reaction rates or biological activity in response to temperature changes, commonly used in biochemical processes & The Wastewater Temperature refers to the measure of heat present in wastewater, affecting treatment efficiency and biological activity, typically measured in degrees Celsius (°C).
How to calculate Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth?
The Treatability Constant at 20 degrees Celsius and 20 ft Filter Depth is defined as a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 20°C at 20ft filter depth is calculated using Treatability Constant at 20°C and 20ft Depth = Treatability Constant at 30°C and 20ft Depth/(Temperature Activity Coefficient)^(Wastewater Temperature-20). To calculate Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth, you need Treatability Constant at 30°C and 20ft Depth (K30/20), Temperature Activity Coefficient (θ) & Wastewater Temperature (T). With our tool, you need to enter the respective value for Treatability Constant at 30°C and 20ft Depth, Temperature Activity Coefficient & Wastewater Temperature and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!