Transverse Dimension of End Zone given Bursting Force for Square End Zone Solution

STEP 0: Pre-Calculation Summary
Formula Used
Traverse Dimension of End Zone = (-0.3*Side Length of Bearing Plate)/((Prestress Bursting force/Prestressing Force)-0.32)
Yo = (-0.3*Ypo)/((Fbst/F)-0.32)
This formula uses 4 Variables
Variables Used
Traverse Dimension of End Zone - (Measured in Centimeter) - Traverse Dimension of End Zone can be defined as the measurement of bearing plate in traverse direction.
Side Length of Bearing Plate - (Measured in Centimeter) - Side Length of Bearing Plate represented the length of the bearing plate in which the burst force is acting.
Prestress Bursting force - (Measured in Kilonewton) - The Prestress Bursting force represents the resultant of the tensile stress in a transverse direction.
Prestressing Force - (Measured in Kilonewton) - Prestressing Force is the force internally applied to the prestressed concrete section.
STEP 1: Convert Input(s) to Base Unit
Side Length of Bearing Plate: 5 Centimeter --> 5 Centimeter No Conversion Required
Prestress Bursting force: 68 Kilonewton --> 68 Kilonewton No Conversion Required
Prestressing Force: 400 Kilonewton --> 400 Kilonewton No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Yo = (-0.3*Ypo)/((Fbst/F)-0.32) --> (-0.3*5)/((68/400)-0.32)
Evaluating ... ...
Yo = 10
STEP 3: Convert Result to Output's Unit
0.1 Meter -->10 Centimeter (Check conversion ​here)
FINAL ANSWER
10 Centimeter <-- Traverse Dimension of End Zone
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by M Naveen
National Institute of Technology (NIT), Warangal
M Naveen has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

Post Tensioned Members Calculators

Prestress in Tendon given Bursting Force for Square End Zone
​ LaTeX ​ Go Prestressing Force = Prestress Bursting force/(0.32-0.3*(Side Length of Bearing Plate/Traverse Dimension of End Zone))
Bursting Force for Square End Zone
​ LaTeX ​ Go Prestress Bursting force = Prestressing Force*(0.32-0.3*(Side Length of Bearing Plate/Traverse Dimension of End Zone))
End Zone Reinforcement along Transmission Length
​ LaTeX ​ Go End Zone Reinforcement = (2.5*Moment in Structures)/(Allowable Stress*Total Depth)
Allowable Stress given End Zone Reinforcement
​ LaTeX ​ Go Allowable Stress = (2.5*Moment in Structures)/(End Zone Reinforcement*Total Depth)

Transverse Dimension of End Zone given Bursting Force for Square End Zone Formula

​LaTeX ​Go
Traverse Dimension of End Zone = (-0.3*Side Length of Bearing Plate)/((Prestress Bursting force/Prestressing Force)-0.32)
Yo = (-0.3*Ypo)/((Fbst/F)-0.32)

What does Prestress in Tendon mean?

Prestress in tendon is defined to introduce internal stresses into (something, such as a structural beam) to counteract the stresses that will result from applied load.

How to Calculate Transverse Dimension of End Zone given Bursting Force for Square End Zone?

Transverse Dimension of End Zone given Bursting Force for Square End Zone calculator uses Traverse Dimension of End Zone = (-0.3*Side Length of Bearing Plate)/((Prestress Bursting force/Prestressing Force)-0.32) to calculate the Traverse Dimension of End Zone, The Transverse Dimension of End Zone given Bursting Force for Square End Zone is defined as measurement of bearing plate at end zone in traverse direction. Traverse Dimension of End Zone is denoted by Yo symbol.

How to calculate Transverse Dimension of End Zone given Bursting Force for Square End Zone using this online calculator? To use this online calculator for Transverse Dimension of End Zone given Bursting Force for Square End Zone, enter Side Length of Bearing Plate (Ypo), Prestress Bursting force (Fbst) & Prestressing Force (F) and hit the calculate button. Here is how the Transverse Dimension of End Zone given Bursting Force for Square End Zone calculation can be explained with given input values -> 1000 = (-0.3*0.05)/((68000/400000)-0.32).

FAQ

What is Transverse Dimension of End Zone given Bursting Force for Square End Zone?
The Transverse Dimension of End Zone given Bursting Force for Square End Zone is defined as measurement of bearing plate at end zone in traverse direction and is represented as Yo = (-0.3*Ypo)/((Fbst/F)-0.32) or Traverse Dimension of End Zone = (-0.3*Side Length of Bearing Plate)/((Prestress Bursting force/Prestressing Force)-0.32). Side Length of Bearing Plate represented the length of the bearing plate in which the burst force is acting, The Prestress Bursting force represents the resultant of the tensile stress in a transverse direction & Prestressing Force is the force internally applied to the prestressed concrete section.
How to calculate Transverse Dimension of End Zone given Bursting Force for Square End Zone?
The Transverse Dimension of End Zone given Bursting Force for Square End Zone is defined as measurement of bearing plate at end zone in traverse direction is calculated using Traverse Dimension of End Zone = (-0.3*Side Length of Bearing Plate)/((Prestress Bursting force/Prestressing Force)-0.32). To calculate Transverse Dimension of End Zone given Bursting Force for Square End Zone, you need Side Length of Bearing Plate (Ypo), Prestress Bursting force (Fbst) & Prestressing Force (F). With our tool, you need to enter the respective value for Side Length of Bearing Plate, Prestress Bursting force & Prestressing Force and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!