Transmissivity about given Storage Coefficient Solution

STEP 0: Pre-Calculation Summary
Formula Used
Transmissivity = (Storage Coefficient*Distance from Pumping Well^2)/(2.25*Starting Time)
T = (S*r^2)/(2.25*t0)
This formula uses 4 Variables
Variables Used
Transmissivity - (Measured in Square Meter per Second) - Transmissivity is the rate at which groundwater flows horizontally through an aquifer or the degree to which a medium allows something, in particular electromagnetic radiation, to pass through it.
Storage Coefficient - Storage Coefficient is the volume of water released from storage per unit decline in hydraulic head in the aquifer, per unit area of the aquifer.
Distance from Pumping Well - (Measured in Meter) - Distance from Pumping Well is the horizontal distance between a specific point in an aquifer and the location of a pumping well. It influences the behavior of groundwater flow.
Starting Time - (Measured in Second) - Starting Time is the initial moment or period when an aquifer test or pumping test begins. This is crucial for understanding the response of the groundwater system to the stress imposed by the test.
STEP 1: Convert Input(s) to Base Unit
Storage Coefficient: 85 --> No Conversion Required
Distance from Pumping Well: 3 Meter --> 3 Meter No Conversion Required
Starting Time: 31 Second --> 31 Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
T = (S*r^2)/(2.25*t0) --> (85*3^2)/(2.25*31)
Evaluating ... ...
T = 10.9677419354839
STEP 3: Convert Result to Output's Unit
10.9677419354839 Square Meter per Second --> No Conversion Required
FINAL ANSWER
10.9677419354839 10.96774 Square Meter per Second <-- Transmissivity
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has created this Calculator and 2000+ more calculators!
Verifier Image
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

Unsteady Flow in a Confined Aquifer Calculators

Drawdown
​ LaTeX ​ Go Total Drawdown = (Discharge/(4*pi*Transmissivity))*ln((2.2*Transmissivity*Time Period)/(Distance from Pumping Well^2*Storage Coefficient))
Drawdown at Time Interval 't1'
​ LaTeX ​ Go Drawdown at Time Interval t1 = Drawdown at Time Interval t2-((Discharge/(4*pi*Transmissivity))*ln(Time of Drawdown (t2)/Time of Drawdown (t1)))
Drawdown at Time Interval 't2'
​ LaTeX ​ Go Drawdown at Time Interval t2 = ((Discharge/(4*pi*Transmissivity))*ln(Time of Drawdown (t2)/Time of Drawdown (t1)))+Drawdown at Time Interval t1
Equation for Storage Coefficient
​ LaTeX ​ Go Storage Coefficient = 2.25*Transmissivity*Starting Time/Distance from Pumping Well^2

Transmissivity about given Storage Coefficient Formula

​LaTeX ​Go
Transmissivity = (Storage Coefficient*Distance from Pumping Well^2)/(2.25*Starting Time)
T = (S*r^2)/(2.25*t0)

What is Storage Coefficient?

Storativity or the storage coefficient is the volume of water released from storage per unit decline in hydraulic head in the aquifer, per unit area of the aquifer. Storativity is a dimensionless quantity, and is always greater than 0.

How to Calculate Transmissivity about given Storage Coefficient?

Transmissivity about given Storage Coefficient calculator uses Transmissivity = (Storage Coefficient*Distance from Pumping Well^2)/(2.25*Starting Time) to calculate the Transmissivity, The Transmissivity about given Storage Coefficient formula is defined as the rate at which groundwater flows horizontally through an aquifer or the degree to which a medium allows something, in particular electromagnetic radiation, to pass through it. Transmissivity is denoted by T symbol.

How to calculate Transmissivity about given Storage Coefficient using this online calculator? To use this online calculator for Transmissivity about given Storage Coefficient, enter Storage Coefficient (S), Distance from Pumping Well (r) & Starting Time (t0) and hit the calculate button. Here is how the Transmissivity about given Storage Coefficient calculation can be explained with given input values -> 10.96774 = (85*3^2)/(2.25*31).

FAQ

What is Transmissivity about given Storage Coefficient?
The Transmissivity about given Storage Coefficient formula is defined as the rate at which groundwater flows horizontally through an aquifer or the degree to which a medium allows something, in particular electromagnetic radiation, to pass through it and is represented as T = (S*r^2)/(2.25*t0) or Transmissivity = (Storage Coefficient*Distance from Pumping Well^2)/(2.25*Starting Time). Storage Coefficient is the volume of water released from storage per unit decline in hydraulic head in the aquifer, per unit area of the aquifer, Distance from Pumping Well is the horizontal distance between a specific point in an aquifer and the location of a pumping well. It influences the behavior of groundwater flow & Starting Time is the initial moment or period when an aquifer test or pumping test begins. This is crucial for understanding the response of the groundwater system to the stress imposed by the test.
How to calculate Transmissivity about given Storage Coefficient?
The Transmissivity about given Storage Coefficient formula is defined as the rate at which groundwater flows horizontally through an aquifer or the degree to which a medium allows something, in particular electromagnetic radiation, to pass through it is calculated using Transmissivity = (Storage Coefficient*Distance from Pumping Well^2)/(2.25*Starting Time). To calculate Transmissivity about given Storage Coefficient, you need Storage Coefficient (S), Distance from Pumping Well (r) & Starting Time (t0). With our tool, you need to enter the respective value for Storage Coefficient, Distance from Pumping Well & Starting Time and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!