Total Work done per cycle in Compressor during Incomplete Intercooling given Volume Solution

STEP 0: Pre-Calculation Summary
Formula Used
Total Work Done per Cycle = (Polytropic Index for Compression/(Polytropic Index for Compression-1))*Suction Pressure of Low Pressure Compressor*Suction Volume of High Pressure Compressor*((Discharge Pressure of Low Pressure Compressor/Suction Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression)-1)+(Polytropic Index for Compression/(Polytropic Index for Compression-1))*Discharge Pressure of Low Pressure Compressor*Discharge Volume of High Pressure Compressor*((Discharge Pressure of High Pressure Compressor/Discharge Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression)-1)
wt = (nc/(nc-1))*P1*V1,hc*((P2/P1)^((nc-1)/nc)-1)+(nc/(nc-1))*P2*V2,hc*((P3/P2)^((nc-1)/nc)-1)
This formula uses 7 Variables
Variables Used
Total Work Done per Cycle - (Measured in Joule) - Total Work Done per cycle is the total energy transferred per cycle in a two-stage compressor, which involves compression in two stages with intermediate cooling.
Polytropic Index for Compression - Polytropic Index for Compression is a measure of the efficiency of a two-stage compressor, indicating the degree of isentropic compression in a real compression process.
Suction Pressure of Low Pressure Compressor - (Measured in Pascal) - Suction Pressure of Low Pressure Compressor is the pressure at which the low-pressure compressor in a two-stage compressor system draws in air or gas.
Suction Volume of High Pressure Compressor - (Measured in Cubic Meter) - Suction Volume of High Pressure Compressor is the volume of air sucked by the high-pressure compressor in a two-stage compression system.
Discharge Pressure of Low Pressure Compressor - (Measured in Pascal) - Discharge Pressure of Low Pressure Compressor is the pressure at which the low-pressure compressor stage of a two-stage compressor discharges compressed air or gas.
Discharge Volume of High Pressure Compressor - (Measured in Cubic Meter) - Discharge Volume of High Pressure Compressor is the volume of gas discharged by the high-pressure compressor in a two-stage compression system.
Discharge Pressure of High Pressure Compressor - (Measured in Pascal) - Discharge Pressure of High Pressure Compressor is the pressure at which the high-pressure compressor stage of a two-stage compressor discharges compressed air or gas.
STEP 1: Convert Input(s) to Base Unit
Polytropic Index for Compression: 1.2 --> No Conversion Required
Suction Pressure of Low Pressure Compressor: 0.002 Bar --> 200 Pascal (Check conversion ​here)
Suction Volume of High Pressure Compressor: 0.001 Cubic Meter --> 0.001 Cubic Meter No Conversion Required
Discharge Pressure of Low Pressure Compressor: 7 Bar --> 700000 Pascal (Check conversion ​here)
Discharge Volume of High Pressure Compressor: 0.6 Cubic Meter --> 0.6 Cubic Meter No Conversion Required
Discharge Pressure of High Pressure Compressor: 15 Bar --> 1500000 Pascal (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
wt = (nc/(nc-1))*P1*V1,hc*((P2/P1)^((nc-1)/nc)-1)+(nc/(nc-1))*P2*V2,hc*((P3/P2)^((nc-1)/nc)-1) --> (1.2/(1.2-1))*200*0.001*((700000/200)^((1.2-1)/1.2)-1)+(1.2/(1.2-1))*700000*0.6*((1500000/700000)^((1.2-1)/1.2)-1)
Evaluating ... ...
wt = 341321.148765162
STEP 3: Convert Result to Output's Unit
341321.148765162 Joule --> No Conversion Required
FINAL ANSWER
341321.148765162 341321.1 Joule <-- Total Work Done per Cycle
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Vishwakarma Institute of Information Technology, Pune (VIIT Pune), Pune
Abhishek Dharmendra Bansile has created this Calculator and 100+ more calculators!
Verifier Image
Verified by sanjay shiva
national institute of technology hamirpur (NITH ), hamirpur , himachal pradesh
sanjay shiva has verified this Calculator and 100+ more calculators!

Work Done by Two Stage Compressor Calculators

Total Work done per cycle in Compressor during Incomplete Intercooling given Volume
​ LaTeX ​ Go Total Work Done per Cycle = (Polytropic Index for Compression/(Polytropic Index for Compression-1))*Suction Pressure of Low Pressure Compressor*Suction Volume of High Pressure Compressor*((Discharge Pressure of Low Pressure Compressor/Suction Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression)-1)+(Polytropic Index for Compression/(Polytropic Index for Compression-1))*Discharge Pressure of Low Pressure Compressor*Discharge Volume of High Pressure Compressor*((Discharge Pressure of High Pressure Compressor/Discharge Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression)-1)
Total Work done per cycle in Compressor during incomplete Intercooling given Temperature
​ LaTeX ​ Go Total Work Done per Cycle = (Polytropic Index for Compression/(Polytropic Index for Compression-1))*Mass of Refrigerant in kg per minute*[R]*((Suction Temperature at Low Pressure Compressor*(Discharge Pressure of Low Pressure Compressor/Suction Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression))+Temperature at Exit of Intercooler*(Discharge Pressure of High Pressure Compressor/Discharge Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression)-Suction Temperature at Low Pressure Compressor-Temperature at Exit of Intercooler)
Work done per cycle in Low Pressure Compressor during incomplete intercooling given Suction Temp
​ LaTeX ​ Go Work Done per Cycle = (Polytropic Index for Compression/(Polytropic Index for Compression-1))*Mass of Refrigerant in kg per minute*[R]*Suction Temperature at Low Pressure Compressor*((Discharge Pressure of Low Pressure Compressor/Suction Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression)-1)
Work done per cycle in Low pressure Compressor during incomplete intercooling given suction volume
​ LaTeX ​ Go Work Done per Cycle = (Polytropic Index for Compression/(Polytropic Index for Compression-1))*Suction Pressure of Low Pressure Compressor*Suction Volume*((Discharge Pressure of Low Pressure Compressor/Suction Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression)-1)

Total Work done per cycle in Compressor during Incomplete Intercooling given Volume Formula

​LaTeX ​Go
Total Work Done per Cycle = (Polytropic Index for Compression/(Polytropic Index for Compression-1))*Suction Pressure of Low Pressure Compressor*Suction Volume of High Pressure Compressor*((Discharge Pressure of Low Pressure Compressor/Suction Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression)-1)+(Polytropic Index for Compression/(Polytropic Index for Compression-1))*Discharge Pressure of Low Pressure Compressor*Discharge Volume of High Pressure Compressor*((Discharge Pressure of High Pressure Compressor/Discharge Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression)-1)
wt = (nc/(nc-1))*P1*V1,hc*((P2/P1)^((nc-1)/nc)-1)+(nc/(nc-1))*P2*V2,hc*((P3/P2)^((nc-1)/nc)-1)

How does a Two stage reciprocating compressor work?

This type of compressor has two pistons which use for air compression. The piston of the L.P cylinder compresses the air and transfers the pressurized air into the second H.P for further compression where the second piston compresses it. These compressors operate with natural gas or electricity.

How to Calculate Total Work done per cycle in Compressor during Incomplete Intercooling given Volume?

Total Work done per cycle in Compressor during Incomplete Intercooling given Volume calculator uses Total Work Done per Cycle = (Polytropic Index for Compression/(Polytropic Index for Compression-1))*Suction Pressure of Low Pressure Compressor*Suction Volume of High Pressure Compressor*((Discharge Pressure of Low Pressure Compressor/Suction Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression)-1)+(Polytropic Index for Compression/(Polytropic Index for Compression-1))*Discharge Pressure of Low Pressure Compressor*Discharge Volume of High Pressure Compressor*((Discharge Pressure of High Pressure Compressor/Discharge Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression)-1) to calculate the Total Work Done per Cycle, Total Work done per cycle in Compressor during Incomplete Intercooling given Volume formula is defined as the energy transferred per cycle in a two-stage compressor with incomplete intercooling, which is a critical parameter in evaluating the performance of a compressor system. Total Work Done per Cycle is denoted by wt symbol.

How to calculate Total Work done per cycle in Compressor during Incomplete Intercooling given Volume using this online calculator? To use this online calculator for Total Work done per cycle in Compressor during Incomplete Intercooling given Volume, enter Polytropic Index for Compression (nc), Suction Pressure of Low Pressure Compressor (P1), Suction Volume of High Pressure Compressor (V1,hc), Discharge Pressure of Low Pressure Compressor (P2), Discharge Volume of High Pressure Compressor (V2,hc) & Discharge Pressure of High Pressure Compressor (P3) and hit the calculate button. Here is how the Total Work done per cycle in Compressor during Incomplete Intercooling given Volume calculation can be explained with given input values -> 341352.4 = (1.2/(1.2-1))*200*0.001*((700000/200)^((1.2-1)/1.2)-1)+(1.2/(1.2-1))*700000*0.6*((1500000/700000)^((1.2-1)/1.2)-1).

FAQ

What is Total Work done per cycle in Compressor during Incomplete Intercooling given Volume?
Total Work done per cycle in Compressor during Incomplete Intercooling given Volume formula is defined as the energy transferred per cycle in a two-stage compressor with incomplete intercooling, which is a critical parameter in evaluating the performance of a compressor system and is represented as wt = (nc/(nc-1))*P1*V1,hc*((P2/P1)^((nc-1)/nc)-1)+(nc/(nc-1))*P2*V2,hc*((P3/P2)^((nc-1)/nc)-1) or Total Work Done per Cycle = (Polytropic Index for Compression/(Polytropic Index for Compression-1))*Suction Pressure of Low Pressure Compressor*Suction Volume of High Pressure Compressor*((Discharge Pressure of Low Pressure Compressor/Suction Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression)-1)+(Polytropic Index for Compression/(Polytropic Index for Compression-1))*Discharge Pressure of Low Pressure Compressor*Discharge Volume of High Pressure Compressor*((Discharge Pressure of High Pressure Compressor/Discharge Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression)-1). Polytropic Index for Compression is a measure of the efficiency of a two-stage compressor, indicating the degree of isentropic compression in a real compression process, Suction Pressure of Low Pressure Compressor is the pressure at which the low-pressure compressor in a two-stage compressor system draws in air or gas, Suction Volume of High Pressure Compressor is the volume of air sucked by the high-pressure compressor in a two-stage compression system, Discharge Pressure of Low Pressure Compressor is the pressure at which the low-pressure compressor stage of a two-stage compressor discharges compressed air or gas, Discharge Volume of High Pressure Compressor is the volume of gas discharged by the high-pressure compressor in a two-stage compression system & Discharge Pressure of High Pressure Compressor is the pressure at which the high-pressure compressor stage of a two-stage compressor discharges compressed air or gas.
How to calculate Total Work done per cycle in Compressor during Incomplete Intercooling given Volume?
Total Work done per cycle in Compressor during Incomplete Intercooling given Volume formula is defined as the energy transferred per cycle in a two-stage compressor with incomplete intercooling, which is a critical parameter in evaluating the performance of a compressor system is calculated using Total Work Done per Cycle = (Polytropic Index for Compression/(Polytropic Index for Compression-1))*Suction Pressure of Low Pressure Compressor*Suction Volume of High Pressure Compressor*((Discharge Pressure of Low Pressure Compressor/Suction Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression)-1)+(Polytropic Index for Compression/(Polytropic Index for Compression-1))*Discharge Pressure of Low Pressure Compressor*Discharge Volume of High Pressure Compressor*((Discharge Pressure of High Pressure Compressor/Discharge Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression)-1). To calculate Total Work done per cycle in Compressor during Incomplete Intercooling given Volume, you need Polytropic Index for Compression (nc), Suction Pressure of Low Pressure Compressor (P1), Suction Volume of High Pressure Compressor (V1,hc), Discharge Pressure of Low Pressure Compressor (P2), Discharge Volume of High Pressure Compressor (V2,hc) & Discharge Pressure of High Pressure Compressor (P3). With our tool, you need to enter the respective value for Polytropic Index for Compression, Suction Pressure of Low Pressure Compressor, Suction Volume of High Pressure Compressor, Discharge Pressure of Low Pressure Compressor, Discharge Volume of High Pressure Compressor & Discharge Pressure of High Pressure Compressor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Total Work Done per Cycle?
In this formula, Total Work Done per Cycle uses Polytropic Index for Compression, Suction Pressure of Low Pressure Compressor, Suction Volume of High Pressure Compressor, Discharge Pressure of Low Pressure Compressor, Discharge Volume of High Pressure Compressor & Discharge Pressure of High Pressure Compressor. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Total Work Done per Cycle = (Polytropic Index for Compression/(Polytropic Index for Compression-1))*Mass of Refrigerant in kg per minute*[R]*((Suction Temperature at Low Pressure Compressor*(Discharge Pressure of Low Pressure Compressor/Suction Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression))+Temperature at Exit of Intercooler*(Discharge Pressure of High Pressure Compressor/Discharge Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression)-Suction Temperature at Low Pressure Compressor-Temperature at Exit of Intercooler)
  • Total Work Done per Cycle = (Polytropic Index for Compression/(Polytropic Index for Compression-1))*Mass of Refrigerant in kg per minute*[R]*Suction Temperature at Low Pressure Compressor*((Discharge Pressure of Low Pressure Compressor/Suction Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression)+(Discharge Pressure of High Pressure Compressor/Discharge Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression)-2)
  • Total Work Done per Cycle = (Polytropic Index for Compression/(Polytropic Index for Compression-1))*Suction Pressure of Low Pressure Compressor*Suction Volume*((Discharge Pressure of Low Pressure Compressor/Suction Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression)+(Discharge Pressure of High Pressure Compressor/Discharge Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression)-2)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!