Total Settling Tank Surface Area given Actual Solid Loading Rate Solution

STEP 0: Pre-Calculation Summary
Formula Used
Surface Area = Solid Processed/Solid Loading Rate
SA = Sp/SLr
This formula uses 3 Variables
Variables Used
Surface Area - (Measured in Square Meter) - Surface Area is the horizontal area available for sedimentation, impacting the tank's capacity to separate solids, typically measured in square meters (m²).
Solid Processed - (Measured in Kilogram per Second) - Solid Processed is the total quantity or volume of solids treated, settled, or removed from the wastewater over a specific period, typically measured in kilograms, tons, or cubic meters.
Solid Loading Rate - (Measured in Kilogram per Second Square Meter) - Solid Loading Rate is the amount of solids applied per unit area of a treatment process, such as a clarifier, typically measured in kilograms per square meter per day (kg/m²/day).
STEP 1: Convert Input(s) to Base Unit
Solid Processed: 80.01 Kilogram per Day --> 0.000926041666666667 Kilogram per Second (Check conversion ​here)
Solid Loading Rate: 20 kilogram per Day Square Meter --> 0.000231481481481481 Kilogram per Second Square Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
SA = Sp/SLr --> 0.000926041666666667/0.000231481481481481
Evaluating ... ...
SA = 4.00050000000001
STEP 3: Convert Result to Output's Unit
4.00050000000001 Square Meter --> No Conversion Required
FINAL ANSWER
4.00050000000001 4.0005 Square Meter <-- Surface Area
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Design of a Circular Settling Tank Calculators

Design Surface Loading Rate given Surface Area of Circular Settling Tank
​ LaTeX ​ Go Surface Loading Rate = (Peak Discharge/Surface Area)
Peak Discharge given Surface Area of Circular Settling Tank
​ LaTeX ​ Go Peak Discharge = (Surface Area*Surface Loading Rate)
Surface Area of Circular Settling Tank
​ LaTeX ​ Go Surface Area = (Peak Discharge/Surface Loading Rate)
Peak Discharge in Circular Settling Tanks
​ LaTeX ​ Go Peak Discharge = Average Daily Load*Peaking Factor

Total Settling Tank Surface Area given Actual Solid Loading Rate Formula

​LaTeX ​Go
Surface Area = Solid Processed/Solid Loading Rate
SA = Sp/SLr

What is Surface Area?

The Surface Area is the measurement of the size of flat surface in a plane (two-dimensional), whereas surface area is the measurement of the exposed surface of a solid shape (three-dimensional).

How to Calculate Total Settling Tank Surface Area given Actual Solid Loading Rate?

Total Settling Tank Surface Area given Actual Solid Loading Rate calculator uses Surface Area = Solid Processed/Solid Loading Rate to calculate the Surface Area, The Total Settling Tank Surface Area given Actual Solid Loading Rate is defined as combined area of all surfaces within the settling tank, typically measured in square meters (m²). Surface Area is denoted by SA symbol.

How to calculate Total Settling Tank Surface Area given Actual Solid Loading Rate using this online calculator? To use this online calculator for Total Settling Tank Surface Area given Actual Solid Loading Rate, enter Solid Processed (Sp) & Solid Loading Rate (SLr) and hit the calculate button. Here is how the Total Settling Tank Surface Area given Actual Solid Loading Rate calculation can be explained with given input values -> 6 = 0.000926041666666667/0.000231481481481481.

FAQ

What is Total Settling Tank Surface Area given Actual Solid Loading Rate?
The Total Settling Tank Surface Area given Actual Solid Loading Rate is defined as combined area of all surfaces within the settling tank, typically measured in square meters (m²) and is represented as SA = Sp/SLr or Surface Area = Solid Processed/Solid Loading Rate. Solid Processed is the total quantity or volume of solids treated, settled, or removed from the wastewater over a specific period, typically measured in kilograms, tons, or cubic meters & Solid Loading Rate is the amount of solids applied per unit area of a treatment process, such as a clarifier, typically measured in kilograms per square meter per day (kg/m²/day).
How to calculate Total Settling Tank Surface Area given Actual Solid Loading Rate?
The Total Settling Tank Surface Area given Actual Solid Loading Rate is defined as combined area of all surfaces within the settling tank, typically measured in square meters (m²) is calculated using Surface Area = Solid Processed/Solid Loading Rate. To calculate Total Settling Tank Surface Area given Actual Solid Loading Rate, you need Solid Processed (Sp) & Solid Loading Rate (SLr). With our tool, you need to enter the respective value for Solid Processed & Solid Loading Rate and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Surface Area?
In this formula, Surface Area uses Solid Processed & Solid Loading Rate. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Surface Area = (Peak Discharge/Surface Loading Rate)
  • Surface Area = Maximum Solids/Solid Loading Rate
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!