Total Projected Area of Bearing Pad in Terms of Load acting on Bearing Solution

STEP 0: Pre-Calculation Summary
Formula Used
Total Projected Area of Bearing Pad = Load Acting on Sliding Bearing/(Pressure of Lubricating Oil*Load Coefficient for Bearing)
Ap = W/(pr*af)
This formula uses 4 Variables
Variables Used
Total Projected Area of Bearing Pad - (Measured in Square Meter) - The Total Projected Area of Bearing Pad is the surface area of the bearing pad that is in contact with the load, influencing load distribution and performance.
Load Acting on Sliding Bearing - (Measured in Newton) - The Load Acting on Sliding Bearing is the force exerted on a sliding bearing surface, crucial for assessing bearing performance and ensuring proper mechanical function.
Pressure of Lubricating Oil - (Measured in Pascal) - The Pressure of Lubricating Oil is the force exerted by the oil within a bearing, essential for reducing friction and ensuring smooth operation in mechanical systems.
Load Coefficient for Bearing - The Load Coefficient for Bearing is a measure of the load-carrying capacity of a bearing, indicating its performance under specific operating conditions.
STEP 1: Convert Input(s) to Base Unit
Load Acting on Sliding Bearing: 1800 Newton --> 1800 Newton No Conversion Required
Pressure of Lubricating Oil: 4.3 Megapascal --> 4300000 Pascal (Check conversion ​here)
Load Coefficient for Bearing: 0.93 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Ap = W/(pr*af) --> 1800/(4300000*0.93)
Evaluating ... ...
Ap = 0.000450112528132033
STEP 3: Convert Result to Output's Unit
0.000450112528132033 Square Meter -->450.112528132033 Square Millimeter (Check conversion ​here)
FINAL ANSWER
450.112528132033 450.1125 Square Millimeter <-- Total Projected Area of Bearing Pad
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Vaibhav Malani
National Institute of Technology (NIT), Tiruchirapalli
Vaibhav Malani has created this Calculator and 600+ more calculators!
Verifier Image
Verified by Anshika Arya
National Institute Of Technology (NIT), Hamirpur
Anshika Arya has verified this Calculator and 2500+ more calculators!

Hydrostatic Step Bearing with Pad Calculators

Length of Slot in Direction of Flow in Terms of Flow of Lubricant
​ Go Length of Slot in Direction of Flow = Pressure Difference between Slot Sides*Breadth of Slot for Oil Flow*(Oil Film thickness^3)/(12*Dynamic Viscosity of Lubricant*Flow of Lubricant from Slot)
Flow of Lubricant through slot in Terms of Pressure Difference
​ Go Flow of Lubricant from Slot = Pressure Difference between Slot Sides*Breadth of Slot for Oil Flow*(Oil Film thickness^3)/(12*Dynamic Viscosity of Lubricant*Length of Slot in Direction of Flow)
Dimension b of Slot given Flow of Lubricant
​ Go Breadth of Slot for Oil Flow = Length of Slot in Direction of Flow*12*Dynamic Viscosity of Lubricant*Flow of Lubricant from Slot/((Oil Film thickness^3)*Pressure Difference between Slot Sides)
Total Projected Area of Bearing Pad
​ Go Total Projected Area of Bearing Pad = Dimension X of Bearing Pad*Dimension Y of Bearing Pad

Total Projected Area of Bearing Pad in Terms of Load acting on Bearing Formula

​Go
Total Projected Area of Bearing Pad = Load Acting on Sliding Bearing/(Pressure of Lubricating Oil*Load Coefficient for Bearing)
Ap = W/(pr*af)

What is Sliding Contact Bearing?

The sliding contact bearings in which the sliding action is along the circumference of a circle or an arc of a circle and carrying radial loads are known as journal or sleeve bearings.

How to Calculate Total Projected Area of Bearing Pad in Terms of Load acting on Bearing?

Total Projected Area of Bearing Pad in Terms of Load acting on Bearing calculator uses Total Projected Area of Bearing Pad = Load Acting on Sliding Bearing/(Pressure of Lubricating Oil*Load Coefficient for Bearing) to calculate the Total Projected Area of Bearing Pad, Total Projected Area of Bearing Pad in Terms of Load acting on Bearing formula is defined as a method to determine the effective area of a bearing pad that supports a load. This area is crucial for ensuring proper load distribution and minimizing wear in mechanical systems. Total Projected Area of Bearing Pad is denoted by Ap symbol.

How to calculate Total Projected Area of Bearing Pad in Terms of Load acting on Bearing using this online calculator? To use this online calculator for Total Projected Area of Bearing Pad in Terms of Load acting on Bearing, enter Load Acting on Sliding Bearing (W), Pressure of Lubricating Oil (pr) & Load Coefficient for Bearing (af) and hit the calculate button. Here is how the Total Projected Area of Bearing Pad in Terms of Load acting on Bearing calculation can be explained with given input values -> 4.5E+8 = 1800/(4300000*0.93).

FAQ

What is Total Projected Area of Bearing Pad in Terms of Load acting on Bearing?
Total Projected Area of Bearing Pad in Terms of Load acting on Bearing formula is defined as a method to determine the effective area of a bearing pad that supports a load. This area is crucial for ensuring proper load distribution and minimizing wear in mechanical systems and is represented as Ap = W/(pr*af) or Total Projected Area of Bearing Pad = Load Acting on Sliding Bearing/(Pressure of Lubricating Oil*Load Coefficient for Bearing). The Load Acting on Sliding Bearing is the force exerted on a sliding bearing surface, crucial for assessing bearing performance and ensuring proper mechanical function, The Pressure of Lubricating Oil is the force exerted by the oil within a bearing, essential for reducing friction and ensuring smooth operation in mechanical systems & The Load Coefficient for Bearing is a measure of the load-carrying capacity of a bearing, indicating its performance under specific operating conditions.
How to calculate Total Projected Area of Bearing Pad in Terms of Load acting on Bearing?
Total Projected Area of Bearing Pad in Terms of Load acting on Bearing formula is defined as a method to determine the effective area of a bearing pad that supports a load. This area is crucial for ensuring proper load distribution and minimizing wear in mechanical systems is calculated using Total Projected Area of Bearing Pad = Load Acting on Sliding Bearing/(Pressure of Lubricating Oil*Load Coefficient for Bearing). To calculate Total Projected Area of Bearing Pad in Terms of Load acting on Bearing, you need Load Acting on Sliding Bearing (W), Pressure of Lubricating Oil (pr) & Load Coefficient for Bearing (af). With our tool, you need to enter the respective value for Load Acting on Sliding Bearing, Pressure of Lubricating Oil & Load Coefficient for Bearing and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Total Projected Area of Bearing Pad?
In this formula, Total Projected Area of Bearing Pad uses Load Acting on Sliding Bearing, Pressure of Lubricating Oil & Load Coefficient for Bearing. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Total Projected Area of Bearing Pad = Dimension X of Bearing Pad*Dimension Y of Bearing Pad
  • Total Projected Area of Bearing Pad = Flow Coefficient*Load Acting on Sliding Bearing*(Oil Film thickness^3)/(Dynamic Viscosity of Lubricant*Flow of Lubricant)