How to Calculate Total Pressure per unit Area for Dams on Soft Foundations?
Total Pressure per unit Area for Dams on Soft Foundations calculator uses Total Pressure at given Point = Depth of Dam*Specific Weight of Water in KN per cubic meter*((Degree of Saturation+Void Ratio)/(1+Void Ratio)) to calculate the Total Pressure at given Point, The Total Pressure per unit Area for Dams on Soft Foundations formula is defined as pressure generated by the water under the dams. Total Pressure at given Point is denoted by P0 symbol.
How to calculate Total Pressure per unit Area for Dams on Soft Foundations using this online calculator? To use this online calculator for Total Pressure per unit Area for Dams on Soft Foundations, enter Depth of Dam (D), Specific Weight of Water in KN per cubic meter (W), Degree of Saturation (S) & Void Ratio (e) and hit the calculate button. Here is how the Total Pressure per unit Area for Dams on Soft Foundations calculation can be explained with given input values -> 109.6936 = 3*9810*((7+1.2)/(1+1.2)).