Time in Hours given Specific Capacity of Open Well Solution

STEP 0: Pre-Calculation Summary
Formula Used
Time = (1/Specific Capacity)*log((Depression Head/Depression Head in Well 2),e)
t = (1/Ka)*log((hd/hw2),e)
This formula uses 1 Constants, 1 Functions, 4 Variables
Constants Used
e - Napier's constant Value Taken As 2.71828182845904523536028747135266249
Functions Used
log - Logarithmic function is an inverse function to exponentiation., log(Base, Number)
Variables Used
Time - (Measured in Second) - Time refers to the ongoing and continuous sequence of events that occur in succession, from the past through the present to the future.
Specific Capacity - (Measured in Meter per Second) - Specific Capacity is capacity of an open well.
Depression Head - (Measured in Meter) - Depression Head is the difference of level of waters table and the water level in the well when pumping stopped.
Depression Head in Well 2 - (Measured in Meter) - Depression Head in Well 2 is depression head in the well at a time T after the pumping stopped.
STEP 1: Convert Input(s) to Base Unit
Specific Capacity: 2 Meter per Hour --> 0.000555555555555556 Meter per Second (Check conversion ​here)
Depression Head: 27 Meter --> 27 Meter No Conversion Required
Depression Head in Well 2: 10 Meter --> 10 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
t = (1/Ka)*log((hd/hw2),e) --> (1/0.000555555555555556)*log((27/10),e)
Evaluating ... ...
t = 1812.22933490939
STEP 3: Convert Result to Output's Unit
1812.22933490939 Second -->0.503397037474831 Hour (Check conversion ​here)
FINAL ANSWER
0.503397037474831 0.503397 Hour <-- Time
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Discharge from Well Calculators

Discharge from Well given Specific Capacity
​ LaTeX ​ Go Discharge in Well = Specific Capacity in SI unit*Cross-Sectional Area of Well*Constant Depression Head
Discharge from Well given Specific Capacity for Clay Soil
​ LaTeX ​ Go Discharge in Well = 0.25*Cross-Sectional Area of Well*Constant Depression Head for Clay Soil
Discharge from Well given Specific Capacity for Coarse Sand
​ LaTeX ​ Go Discharge in Well = 1*Cross-Sectional Area of Well*Constant Depression Head for Coarse Sand
Discharge from Well given Specific Capacity for Fine Sand
​ LaTeX ​ Go Discharge in Well = 0.5*Cross-Sectional Area of Well*Constant Depression Head for Fine Soil

Time in Hours given Specific Capacity of Open Well Formula

​LaTeX ​Go
Time = (1/Specific Capacity)*log((Depression Head/Depression Head in Well 2),e)
t = (1/Ka)*log((hd/hw2),e)

What is Specific Capacity?

Specific Capacity refers to the efficiency of a well in producing water. It is a measure of how much water (in volume) a well can yield per unit of drawdown (or drop in water level) over a specific period of time. The specific capacity is typically expressed in units such as gallons per minute per foot (gpm/ft) or liters per second per meter (L/s/m).

How to Calculate Time in Hours given Specific Capacity of Open Well?

Time in Hours given Specific Capacity of Open Well calculator uses Time = (1/Specific Capacity)*log((Depression Head/Depression Head in Well 2),e) to calculate the Time, The Time in Hours given Specific Capacity of Open Well formula is defined as the calculation of value of time in hours when we have prior information of specific capacity of open well. Time is denoted by t symbol.

How to calculate Time in Hours given Specific Capacity of Open Well using this online calculator? To use this online calculator for Time in Hours given Specific Capacity of Open Well, enter Specific Capacity (Ka), Depression Head (hd) & Depression Head in Well 2 (hw2) and hit the calculate button. Here is how the Time in Hours given Specific Capacity of Open Well calculation can be explained with given input values -> 0.00014 = (1/0.000555555555555556)*log((27/10),e).

FAQ

What is Time in Hours given Specific Capacity of Open Well?
The Time in Hours given Specific Capacity of Open Well formula is defined as the calculation of value of time in hours when we have prior information of specific capacity of open well and is represented as t = (1/Ka)*log((hd/hw2),e) or Time = (1/Specific Capacity)*log((Depression Head/Depression Head in Well 2),e). Specific Capacity is capacity of an open well, Depression Head is the difference of level of waters table and the water level in the well when pumping stopped & Depression Head in Well 2 is depression head in the well at a time T after the pumping stopped.
How to calculate Time in Hours given Specific Capacity of Open Well?
The Time in Hours given Specific Capacity of Open Well formula is defined as the calculation of value of time in hours when we have prior information of specific capacity of open well is calculated using Time = (1/Specific Capacity)*log((Depression Head/Depression Head in Well 2),e). To calculate Time in Hours given Specific Capacity of Open Well, you need Specific Capacity (Ka), Depression Head (hd) & Depression Head in Well 2 (hw2). With our tool, you need to enter the respective value for Specific Capacity, Depression Head & Depression Head in Well 2 and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Time?
In this formula, Time uses Specific Capacity, Depression Head & Depression Head in Well 2. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Time = (2.303/Specific Capacity)*log((Depression Head/Depression Head in Well 2),10)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!