Thickness of Aquifer given Drawdown Value measured at Well Solution

STEP 0: Pre-Calculation Summary
Formula Used
Thickness of Aquifer = Total Drawdown+Depth of Water
b = st+hw
This formula uses 3 Variables
Variables Used
Thickness of Aquifer - (Measured in Meter) - The Thickness of Aquifer vertical thickness of the hydro geologically defined aquifer in which the pore spaces of the rock forming the aquifer are filled with water.
Total Drawdown - (Measured in Meter) - The Total Drawdown is defined as the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test.
Depth of Water - (Measured in Meter) - Depth of Water is the depth in the well measured above the impermeable layer.
STEP 1: Convert Input(s) to Base Unit
Total Drawdown: 0.83 Meter --> 0.83 Meter No Conversion Required
Depth of Water: 2.44 Meter --> 2.44 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
b = st+hw --> 0.83+2.44
Evaluating ... ...
b = 3.27
STEP 3: Convert Result to Output's Unit
3.27 Meter --> No Conversion Required
FINAL ANSWER
3.27 Meter <-- Thickness of Aquifer
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Aquifer Thickness Calculators

Thickness of Aquifer given Discharge in Unconfined Aquifer
​ LaTeX ​ Go Thickness of Unconfined Aquifer = sqrt(Depth of Water^2+(Discharge*log((Radius of Influence/Radius of Well),e))/(pi*Coefficient of Permeability in Well Hydraulics))
Thickness of Aquifer for Discharge in Unconfined Aquifer with Base 10
​ LaTeX ​ Go Thickness of Aquifer = sqrt(Depth of Water^2+(Discharge*log((Radius of Influence/Radius of Well),10))/(1.36*Standard Coefficient of Permeability at 20°C))
Cross-section Area of Soil Mass given Flow Velocity
​ LaTeX ​ Go Area of Cross Section in Enviro. Engin. = (Rate of Flow in Aquifer/Flow Velocity for Unconfined Aquifer)
Thickness of Aquifer given Drawdown Value measured at Well
​ LaTeX ​ Go Thickness of Aquifer = Total Drawdown+Depth of Water

Thickness of Aquifer given Drawdown Value measured at Well Formula

​LaTeX ​Go
Thickness of Aquifer = Total Drawdown+Depth of Water
b = st+hw

What is Drawdown?

A drawdown is a peak-to-trough decline during a specific period for an investment, trading account, or fund. A drawdown is usually quoted as the percentage between the peak and the subsequent trough.

How to Calculate Thickness of Aquifer given Drawdown Value measured at Well?

Thickness of Aquifer given Drawdown Value measured at Well calculator uses Thickness of Aquifer = Total Drawdown+Depth of Water to calculate the Thickness of Aquifer, The Thickness of Aquifer given Drawdown Value measured at Well formula is defined as the value of thickness of aquifer when we have prior information of drawdown. Thickness of Aquifer is denoted by b symbol.

How to calculate Thickness of Aquifer given Drawdown Value measured at Well using this online calculator? To use this online calculator for Thickness of Aquifer given Drawdown Value measured at Well, enter Total Drawdown (st) & Depth of Water (hw) and hit the calculate button. Here is how the Thickness of Aquifer given Drawdown Value measured at Well calculation can be explained with given input values -> 3.27 = 0.83+2.44.

FAQ

What is Thickness of Aquifer given Drawdown Value measured at Well?
The Thickness of Aquifer given Drawdown Value measured at Well formula is defined as the value of thickness of aquifer when we have prior information of drawdown and is represented as b = st+hw or Thickness of Aquifer = Total Drawdown+Depth of Water. The Total Drawdown is defined as the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test & Depth of Water is the depth in the well measured above the impermeable layer.
How to calculate Thickness of Aquifer given Drawdown Value measured at Well?
The Thickness of Aquifer given Drawdown Value measured at Well formula is defined as the value of thickness of aquifer when we have prior information of drawdown is calculated using Thickness of Aquifer = Total Drawdown+Depth of Water. To calculate Thickness of Aquifer given Drawdown Value measured at Well, you need Total Drawdown (st) & Depth of Water (hw). With our tool, you need to enter the respective value for Total Drawdown & Depth of Water and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Thickness of Aquifer?
In this formula, Thickness of Aquifer uses Total Drawdown & Depth of Water. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Thickness of Aquifer = sqrt(Depth of Water^2+(Discharge*log((Radius of Influence/Radius of Well),10))/(1.36*Standard Coefficient of Permeability at 20°C))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!