Thickness of Counterfort Shear Unit Stress on Horizontal Section Solution

STEP 0: Pre-Calculation Summary
Formula Used
Thickness of Counterfort = Normal Shear Unit Stress/(Counterfort Shear Unit Stress*Horizontal Distance)
tc = Vo/(vc*d)
This formula uses 4 Variables
Variables Used
Thickness of Counterfort - (Measured in Meter) - Thickness of Counterfort is the thickness of a buttress built against or integral with a wall (as a retaining wall or dam) but on the back or thrust-receiving side.
Normal Shear Unit Stress - (Measured in Pascal) - Normal Shear Unit Stress is the shear stress acting perpendicularly.
Counterfort Shear Unit Stress - (Measured in Pascal) - Counterfort Shear Unit Stress is the unit stress acting on a horizontal section.
Horizontal Distance - (Measured in Meter) - Horizontal Distance is the distance from face of wall to main steel.
STEP 1: Convert Input(s) to Base Unit
Normal Shear Unit Stress: 8 Megapascal --> 8000000 Pascal (Check conversion ​here)
Counterfort Shear Unit Stress: 3.2 Megapascal --> 3200000 Pascal (Check conversion ​here)
Horizontal Distance: 500.2 Meter --> 500.2 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
tc = Vo/(vc*d) --> 8000000/(3200000*500.2)
Evaluating ... ...
tc = 0.00499800079968013
STEP 3: Convert Result to Output's Unit
0.00499800079968013 Meter -->4.99800079968013 Millimeter (Check conversion ​here)
FINAL ANSWER
4.99800079968013 4.998001 Millimeter <-- Thickness of Counterfort
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Rachana B V
The National Institute of Engineering (NIE), Mysuru
Rachana B V has created this Calculator and 25+ more calculators!
Verifier Image
Verified by Ayush Singh
Gautam Buddha University (GBU), Greater Noida
Ayush Singh has verified this Calculator and 100+ more calculators!

Cantilever and Counterfort Retaining Walls Calculators

Shear Force on Section for Vertical Wall Face
​ LaTeX ​ Go Shear Force on Section = Shear on Section 1+(Bending Moment/Horizontal Distance)*tan(Angle between Earth and Wall)
Thickness of Counterfort Shear Unit Stress on Horizontal Section
​ LaTeX ​ Go Thickness of Counterfort = Normal Shear Unit Stress/(Counterfort Shear Unit Stress*Horizontal Distance)
Counterfort Shear Unit Stress on Horizontal Section
​ LaTeX ​ Go Counterfort Shear Unit Stress = Normal Shear Unit Stress/(Thickness of Counterfort*Horizontal Distance)
Normal Shear Unit Stress on Horizontal Section
​ LaTeX ​ Go Normal Shear Unit Stress = (Counterfort Shear Unit Stress*Thickness of Counterfort*Horizontal Distance)

Thickness of Counterfort Shear Unit Stress on Horizontal Section Formula

​LaTeX ​Go
Thickness of Counterfort = Normal Shear Unit Stress/(Counterfort Shear Unit Stress*Horizontal Distance)
tc = Vo/(vc*d)

What is a Counterfort?

It is a buttress built against or integral with a wall (as a retaining wall or dam) but on the back or thrust-receiving side.

How to Calculate Thickness of Counterfort Shear Unit Stress on Horizontal Section?

Thickness of Counterfort Shear Unit Stress on Horizontal Section calculator uses Thickness of Counterfort = Normal Shear Unit Stress/(Counterfort Shear Unit Stress*Horizontal Distance) to calculate the Thickness of Counterfort, The Thickness of Counterfort Shear Unit Stress on Horizontal Section formula is defined as the width of supporting elements resisting lateral forces in retaining walls or similar structures. Thickness of Counterfort is denoted by tc symbol.

How to calculate Thickness of Counterfort Shear Unit Stress on Horizontal Section using this online calculator? To use this online calculator for Thickness of Counterfort Shear Unit Stress on Horizontal Section, enter Normal Shear Unit Stress (Vo), Counterfort Shear Unit Stress (vc) & Horizontal Distance (d) and hit the calculate button. Here is how the Thickness of Counterfort Shear Unit Stress on Horizontal Section calculation can be explained with given input values -> 4998.001 = 8000000/(3200000*500.2).

FAQ

What is Thickness of Counterfort Shear Unit Stress on Horizontal Section?
The Thickness of Counterfort Shear Unit Stress on Horizontal Section formula is defined as the width of supporting elements resisting lateral forces in retaining walls or similar structures and is represented as tc = Vo/(vc*d) or Thickness of Counterfort = Normal Shear Unit Stress/(Counterfort Shear Unit Stress*Horizontal Distance). Normal Shear Unit Stress is the shear stress acting perpendicularly, Counterfort Shear Unit Stress is the unit stress acting on a horizontal section & Horizontal Distance is the distance from face of wall to main steel.
How to calculate Thickness of Counterfort Shear Unit Stress on Horizontal Section?
The Thickness of Counterfort Shear Unit Stress on Horizontal Section formula is defined as the width of supporting elements resisting lateral forces in retaining walls or similar structures is calculated using Thickness of Counterfort = Normal Shear Unit Stress/(Counterfort Shear Unit Stress*Horizontal Distance). To calculate Thickness of Counterfort Shear Unit Stress on Horizontal Section, you need Normal Shear Unit Stress (Vo), Counterfort Shear Unit Stress (vc) & Horizontal Distance (d). With our tool, you need to enter the respective value for Normal Shear Unit Stress, Counterfort Shear Unit Stress & Horizontal Distance and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!