Thickness of Confined Aquifer given Discharge in Confined Aquifer with Base 10 Solution

STEP 0: Pre-Calculation Summary
Formula Used
Aquifer Thickness given Confined Aquifer Discharge = Discharge in Confined Aquifer/((2.72*Coefficient of Permeability in Well Hydraulics*(Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),10)))
taq = Qc/((2.72*KWH*(bw-hw))/(log((Rw/r),10)))
This formula uses 1 Functions, 7 Variables
Functions Used
log - Logarithmic function is an inverse function to exponentiation., log(Base, Number)
Variables Used
Aquifer Thickness given Confined Aquifer Discharge - (Measured in Meter) - Aquifer Thickness given Confined Aquifer Discharge is the thickness of an aquifer based on the rate of water discharge from a confined aquifer.
Discharge in Confined Aquifer - (Measured in Cubic Meter per Second) - Discharge in Confined Aquifer is the amount of water that is released from a confined aquifer.
Coefficient of Permeability in Well Hydraulics - (Measured in Meter per Second) - Coefficient of Permeability in Well Hydraulics of soil in well hydraulics describes how easily a liquid will move through the soil.
Aquifer Thickness - (Measured in Meter) - Aquifer Thickness (at Midpoint between Equipotential lines) or otherwise is the thickness of aquifer in which the pore spaces of rock forming the aquifer may or may not be with water.
Depth of Water - (Measured in Meter) - Depth of Water is the depth in the well measured above the impermeable layer.
Radius of Influence - (Measured in Meter) - Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table.
Radius of Well - (Measured in Meter) - Radius of Well is defined as the distance from center of well to its outer boundary.
STEP 1: Convert Input(s) to Base Unit
Discharge in Confined Aquifer: 0.04 Cubic Meter per Second --> 0.04 Cubic Meter per Second No Conversion Required
Coefficient of Permeability in Well Hydraulics: 10 Centimeter per Second --> 0.1 Meter per Second (Check conversion ​here)
Aquifer Thickness: 14.15 Meter --> 14.15 Meter No Conversion Required
Depth of Water: 2.44 Meter --> 2.44 Meter No Conversion Required
Radius of Influence: 8.6 Meter --> 8.6 Meter No Conversion Required
Radius of Well: 7.5 Meter --> 7.5 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
taq = Qc/((2.72*KWH*(bw-hw))/(log((Rw/r),10))) --> 0.04/((2.72*0.1*(14.15-2.44))/(log((8.6/7.5),10)))
Evaluating ... ...
taq = 0.211288538334417
STEP 3: Convert Result to Output's Unit
0.211288538334417 Meter --> No Conversion Required
FINAL ANSWER
0.211288538334417 0.211289 Meter <-- Aquifer Thickness given Confined Aquifer Discharge
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Aquifer Thickness Calculators

Thickness of Confined Aquifer given Discharge in Confined Aquifer
​ Go Aquifer Thickness During Pumping = Discharge/((2*pi*Coefficient of Permeability*(Initial Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),e)))
Thickness of Confined Aquifer given Discharge in Confined Aquifer with Base 10
​ Go Aquifer Thickness given Confined Aquifer Discharge = Discharge in Confined Aquifer/((2.72*Coefficient of Permeability in Well Hydraulics*(Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),10)))
Aquifer Thickness from Impermeable Layer given Discharge in Confined Aquifer
​ Go Initial Aquifer Thickness = Depth of Water+((Discharge*log((Radius of Influence/Radius of Well),e))/(2*pi*Coefficient of Permeability*Aquifer Thickness))
Aquifer Thickness from Impermeable Layer given Discharge in Confined Aquifer with Base 10
​ Go Initial Aquifer Thickness = Depth of Water+((Discharge*log((Radius of Influence/Radius of Well),10))/(2.72*Coefficient of Permeability*Aquifer Thickness))

Thickness of Confined Aquifer given Discharge in Confined Aquifer with Base 10 Formula

Aquifer Thickness given Confined Aquifer Discharge = Discharge in Confined Aquifer/((2.72*Coefficient of Permeability in Well Hydraulics*(Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),10)))
taq = Qc/((2.72*KWH*(bw-hw))/(log((Rw/r),10)))

What is Aquifer?

An aquifer is an underground layer of water-bearing permeable rock, rock fractures or unconsolidated materials (gravel, sand, or silt). Groundwater can be extracted using a water well.

How to Calculate Thickness of Confined Aquifer given Discharge in Confined Aquifer with Base 10?

Thickness of Confined Aquifer given Discharge in Confined Aquifer with Base 10 calculator uses Aquifer Thickness given Confined Aquifer Discharge = Discharge in Confined Aquifer/((2.72*Coefficient of Permeability in Well Hydraulics*(Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),10))) to calculate the Aquifer Thickness given Confined Aquifer Discharge, The Thickness of Confined Aquifer given Discharge in Confined Aquifer with Base 10 formula is defined as the value of thickness of confined aquifer when we have prior information of discharge in aquifer. Aquifer Thickness given Confined Aquifer Discharge is denoted by taq symbol.

How to calculate Thickness of Confined Aquifer given Discharge in Confined Aquifer with Base 10 using this online calculator? To use this online calculator for Thickness of Confined Aquifer given Discharge in Confined Aquifer with Base 10, enter Discharge in Confined Aquifer (Qc), Coefficient of Permeability in Well Hydraulics (KWH), Aquifer Thickness (bw), Depth of Water (hw), Radius of Influence (Rw) & Radius of Well (r) and hit the calculate button. Here is how the Thickness of Confined Aquifer given Discharge in Confined Aquifer with Base 10 calculation can be explained with given input values -> 0.211289 = 0.04/((2.72*0.1*(14.15-2.44))/(log((8.6/7.5),10))).

FAQ

What is Thickness of Confined Aquifer given Discharge in Confined Aquifer with Base 10?
The Thickness of Confined Aquifer given Discharge in Confined Aquifer with Base 10 formula is defined as the value of thickness of confined aquifer when we have prior information of discharge in aquifer and is represented as taq = Qc/((2.72*KWH*(bw-hw))/(log((Rw/r),10))) or Aquifer Thickness given Confined Aquifer Discharge = Discharge in Confined Aquifer/((2.72*Coefficient of Permeability in Well Hydraulics*(Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),10))). Discharge in Confined Aquifer is the amount of water that is released from a confined aquifer, Coefficient of Permeability in Well Hydraulics of soil in well hydraulics describes how easily a liquid will move through the soil, Aquifer Thickness (at Midpoint between Equipotential lines) or otherwise is the thickness of aquifer in which the pore spaces of rock forming the aquifer may or may not be with water, Depth of Water is the depth in the well measured above the impermeable layer, Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table & Radius of Well is defined as the distance from center of well to its outer boundary.
How to calculate Thickness of Confined Aquifer given Discharge in Confined Aquifer with Base 10?
The Thickness of Confined Aquifer given Discharge in Confined Aquifer with Base 10 formula is defined as the value of thickness of confined aquifer when we have prior information of discharge in aquifer is calculated using Aquifer Thickness given Confined Aquifer Discharge = Discharge in Confined Aquifer/((2.72*Coefficient of Permeability in Well Hydraulics*(Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),10))). To calculate Thickness of Confined Aquifer given Discharge in Confined Aquifer with Base 10, you need Discharge in Confined Aquifer (Qc), Coefficient of Permeability in Well Hydraulics (KWH), Aquifer Thickness (bw), Depth of Water (hw), Radius of Influence (Rw) & Radius of Well (r). With our tool, you need to enter the respective value for Discharge in Confined Aquifer, Coefficient of Permeability in Well Hydraulics, Aquifer Thickness, Depth of Water, Radius of Influence & Radius of Well and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Aquifer Thickness given Confined Aquifer Discharge?
In this formula, Aquifer Thickness given Confined Aquifer Discharge uses Discharge in Confined Aquifer, Coefficient of Permeability in Well Hydraulics, Aquifer Thickness, Depth of Water, Radius of Influence & Radius of Well. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Aquifer Thickness given Confined Aquifer Discharge = Discharge/((2.72*Coefficient of Permeability*Total Drawdown)/(log((Radius of Influence/Radius of Well),10)))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!