Thermal Resistance of Wall Solution

STEP 0: Pre-Calculation Summary
Formula Used
Thermal Resistance = Length/(Thermal Conductivity*Cross-Sectional Area)
Rth = L/(k*A)
This formula uses 4 Variables
Variables Used
Thermal Resistance - (Measured in Kelvin per Watt) - Thermal resistance is a heat property and a measurement of a temperature difference by which an object or material resists a heat flow.
Length - (Measured in Meter) - Length is the measurement or extent of something from end to end.
Thermal Conductivity - (Measured in Watt per Meter per K) - Thermal Conductivity is rate of heat passes through specified material, expressed as amount of heat flows per unit time through a unit area with a temperature gradient of one degree per unit distance.
Cross-Sectional Area - (Measured in Square Meter) - Cross-Sectional Area is the area of a two-dimensional shape that is obtained when a three-dimensional shape is sliced perpendicular to some specified axis at a point.
STEP 1: Convert Input(s) to Base Unit
Length: 3 Meter --> 3 Meter No Conversion Required
Thermal Conductivity: 10 Watt per Meter per K --> 10 Watt per Meter per K No Conversion Required
Cross-Sectional Area: 13 Square Meter --> 13 Square Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Rth = L/(k*A) --> 3/(10*13)
Evaluating ... ...
Rth = 0.0230769230769231
STEP 3: Convert Result to Output's Unit
0.0230769230769231 Kelvin per Watt --> No Conversion Required
FINAL ANSWER
0.0230769230769231 0.023077 Kelvin per Watt <-- Thermal Resistance
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Vallurupalli Nageswara Rao Vignana Jyothi Institute of Engineering and Technology (VNRVJIET), Hyderabad
Sai Venkata Phanindra Chary Arendra has created this Calculator and 100+ more calculators!
Verifier Image
Verified by Maiarutselvan V
PSG College of Technology (PSGCT), Coimbatore
Maiarutselvan V has verified this Calculator and 300+ more calculators!

Single Plane Wall Calculators

Thermal Conductivity of Material Required to Maintain Given Temperature Difference
​ LaTeX ​ Go Thermal Conductivity = (Heat Flow Rate*Length)/((Inner Surface Temperature-Outer Surface Temperature)*Area of Wall)
Area of Plane Wall Required for Given Temperature Difference
​ LaTeX ​ Go Area of Wall = (Heat Flow Rate*Length)/(Thermal Conductivity*(Inner Surface Temperature-Outer Surface Temperature))
Thickness of Plane Wall for Conduction through Wall
​ LaTeX ​ Go Length = ((Inner Surface Temperature-Outer Surface Temperature)*Thermal Conductivity*Area of Wall)/Heat Flow Rate
Thermal Resistance of Wall
​ LaTeX ​ Go Thermal Resistance = Length/(Thermal Conductivity*Cross-Sectional Area)

Thermal Resistance of Wall Formula

​LaTeX ​Go
Thermal Resistance = Length/(Thermal Conductivity*Cross-Sectional Area)
Rth = L/(k*A)

What is Thermal resistance?

Thermal resistance is a heat property and a measurement of a temperature difference by which an object or material resists a heat flow. Thermal resistance is the reciprocal of thermal conductance. For a wall, it is obtained by dividing the length of the wall along the heat flow by the product of its thermal conductivity and the area perpendicular to the heat flow.

How to Calculate Thermal Resistance of Wall?

Thermal Resistance of Wall calculator uses Thermal Resistance = Length/(Thermal Conductivity*Cross-Sectional Area) to calculate the Thermal Resistance, Thermal Resistance of Wall is a heat property and a measurement of a temperature difference by which a wall resists a heat flow. Thermal resistance is the reciprocal of thermal conductance. Thermal Resistance is denoted by Rth symbol.

How to calculate Thermal Resistance of Wall using this online calculator? To use this online calculator for Thermal Resistance of Wall, enter Length (L), Thermal Conductivity (k) & Cross-Sectional Area (A) and hit the calculate button. Here is how the Thermal Resistance of Wall calculation can be explained with given input values -> 0.023077 = 3/(10*13).

FAQ

What is Thermal Resistance of Wall?
Thermal Resistance of Wall is a heat property and a measurement of a temperature difference by which a wall resists a heat flow. Thermal resistance is the reciprocal of thermal conductance and is represented as Rth = L/(k*A) or Thermal Resistance = Length/(Thermal Conductivity*Cross-Sectional Area). Length is the measurement or extent of something from end to end, Thermal Conductivity is rate of heat passes through specified material, expressed as amount of heat flows per unit time through a unit area with a temperature gradient of one degree per unit distance & Cross-Sectional Area is the area of a two-dimensional shape that is obtained when a three-dimensional shape is sliced perpendicular to some specified axis at a point.
How to calculate Thermal Resistance of Wall?
Thermal Resistance of Wall is a heat property and a measurement of a temperature difference by which a wall resists a heat flow. Thermal resistance is the reciprocal of thermal conductance is calculated using Thermal Resistance = Length/(Thermal Conductivity*Cross-Sectional Area). To calculate Thermal Resistance of Wall, you need Length (L), Thermal Conductivity (k) & Cross-Sectional Area (A). With our tool, you need to enter the respective value for Length, Thermal Conductivity & Cross-Sectional Area and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!