Theoretical Oxygen requirements using Conversion Factor Solution

STEP 0: Pre-Calculation Summary
Formula Used
Theoretical Oxygen Requirement = ((Average Daily Influent Flow Rate*(Influent Substrate Concentration-Effluent Substrate Concentration)*8.34)/BOD Conversion Factor)-(1.42*Net Waste Activated Sludge)
O2 = ((Qa*(So-S)*8.34)/f)-(1.42*Px)
This formula uses 6 Variables
Variables Used
Theoretical Oxygen Requirement - (Measured in Kilogram per Second) - Theoretical Oxygen Requirement is the calculated amount of oxygen required to oxidize a compound to its final oxidation products.
Average Daily Influent Flow Rate - (Measured in Cubic Meter per Second) - Average Daily Influent Flow Rate is the total discharge that comes in the reactor.
Influent Substrate Concentration - (Measured in Kilogram per Cubic Meter) - Influent Substrate Concentration refers to the concentration of organic matter or nutrients in the raw wastewater entering a treatment plant.
Effluent Substrate Concentration - (Measured in Kilogram per Cubic Meter) - Effluent Substrate Concentration refers to the concentration of organic matter or nutrients present in the treated wastewater (effluent) that is discharged from a wastewater treatment plant.
BOD Conversion Factor - BOD Conversion Factor is the value that is multiplied in the 5 days BOD to get the value of ultimate BOD.
Net Waste Activated Sludge - (Measured in Kilogram per Second) - Net Waste Activated Sludge is the amount of waste product that can be treated using the activated sludge process.
STEP 1: Convert Input(s) to Base Unit
Average Daily Influent Flow Rate: 1.2 Cubic Meter per Day --> 1.38888888888889E-05 Cubic Meter per Second (Check conversion ​here)
Influent Substrate Concentration: 25 Milligram per Liter --> 0.025 Kilogram per Cubic Meter (Check conversion ​here)
Effluent Substrate Concentration: 15 Milligram per Liter --> 0.015 Kilogram per Cubic Meter (Check conversion ​here)
BOD Conversion Factor: 0.68 --> No Conversion Required
Net Waste Activated Sludge: 20 Milligram per Day --> 2.31481481481481E-10 Kilogram per Second (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
O2 = ((Qa*(So-S)*8.34)/f)-(1.42*Px) --> ((1.38888888888889E-05*(0.025-0.015)*8.34)/0.68)-(1.42*2.31481481481481E-10)
Evaluating ... ...
O2 = 1.70310266884532E-06
STEP 3: Convert Result to Output's Unit
1.70310266884532E-06 Kilogram per Second -->147148.070588235 Milligram per Day (Check conversion ​here)
FINAL ANSWER
147148.070588235 147148.1 Milligram per Day <-- Theoretical Oxygen Requirement
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

Theoretical Oxygen Requirement Calculators

Theoretical Oxygen requirements using Conversion Factor
​ LaTeX ​ Go Theoretical Oxygen Requirement = ((Average Daily Influent Flow Rate*(Influent Substrate Concentration-Effluent Substrate Concentration)*8.34)/BOD Conversion Factor)-(1.42*Net Waste Activated Sludge)
Theoretical Oxygen Requirement for removal of Carbonaceous Organic Matter
​ LaTeX ​ Go Theoretical Oxygen Requirement = Total BOD Utilized-(1.42*Mass of Organisms Wasted)
Total Mass of BOD Utilized given Theoretical Oxygen Requirement
​ LaTeX ​ Go Total BOD Utilized = Theoretical Oxygen Requirement+(1.42*Mass of Organisms Wasted)
Mass of Organisms Wasted given Theoretical Oxygen Requirement
​ LaTeX ​ Go Mass of Organisms Wasted = (Total BOD Utilized-Theoretical Oxygen Requirement)/1.42

Theoretical Oxygen requirements using Conversion Factor Formula

​LaTeX ​Go
Theoretical Oxygen Requirement = ((Average Daily Influent Flow Rate*(Influent Substrate Concentration-Effluent Substrate Concentration)*8.34)/BOD Conversion Factor)-(1.42*Net Waste Activated Sludge)
O2 = ((Qa*(So-S)*8.34)/f)-(1.42*Px)

What is Conversion Factor?

Conversion Factor is the value that is multiplied in the 5 days BOD to get the value of the ultimate BOD.

How to Calculate Theoretical Oxygen requirements using Conversion Factor?

Theoretical Oxygen requirements using Conversion Factor calculator uses Theoretical Oxygen Requirement = ((Average Daily Influent Flow Rate*(Influent Substrate Concentration-Effluent Substrate Concentration)*8.34)/BOD Conversion Factor)-(1.42*Net Waste Activated Sludge) to calculate the Theoretical Oxygen Requirement, The Theoretical Oxygen requirements using Conversion Factor formula is defined as the amount of oxygen required to oxidize a compound to its final oxidation products. Theoretical Oxygen Requirement is denoted by O2 symbol.

How to calculate Theoretical Oxygen requirements using Conversion Factor using this online calculator? To use this online calculator for Theoretical Oxygen requirements using Conversion Factor, enter Average Daily Influent Flow Rate (Qa), Influent Substrate Concentration (So), Effluent Substrate Concentration (S), BOD Conversion Factor (f) & Net Waste Activated Sludge (Px) and hit the calculate button. Here is how the Theoretical Oxygen requirements using Conversion Factor calculation can be explained with given input values -> 1.3E+16 = ((1.38888888888889E-05*(0.025-0.015)*8.34)/0.68)-(1.42*2.31481481481481E-10).

FAQ

What is Theoretical Oxygen requirements using Conversion Factor?
The Theoretical Oxygen requirements using Conversion Factor formula is defined as the amount of oxygen required to oxidize a compound to its final oxidation products and is represented as O2 = ((Qa*(So-S)*8.34)/f)-(1.42*Px) or Theoretical Oxygen Requirement = ((Average Daily Influent Flow Rate*(Influent Substrate Concentration-Effluent Substrate Concentration)*8.34)/BOD Conversion Factor)-(1.42*Net Waste Activated Sludge). Average Daily Influent Flow Rate is the total discharge that comes in the reactor, Influent Substrate Concentration refers to the concentration of organic matter or nutrients in the raw wastewater entering a treatment plant, Effluent Substrate Concentration refers to the concentration of organic matter or nutrients present in the treated wastewater (effluent) that is discharged from a wastewater treatment plant, BOD Conversion Factor is the value that is multiplied in the 5 days BOD to get the value of ultimate BOD & Net Waste Activated Sludge is the amount of waste product that can be treated using the activated sludge process.
How to calculate Theoretical Oxygen requirements using Conversion Factor?
The Theoretical Oxygen requirements using Conversion Factor formula is defined as the amount of oxygen required to oxidize a compound to its final oxidation products is calculated using Theoretical Oxygen Requirement = ((Average Daily Influent Flow Rate*(Influent Substrate Concentration-Effluent Substrate Concentration)*8.34)/BOD Conversion Factor)-(1.42*Net Waste Activated Sludge). To calculate Theoretical Oxygen requirements using Conversion Factor, you need Average Daily Influent Flow Rate (Qa), Influent Substrate Concentration (So), Effluent Substrate Concentration (S), BOD Conversion Factor (f) & Net Waste Activated Sludge (Px). With our tool, you need to enter the respective value for Average Daily Influent Flow Rate, Influent Substrate Concentration, Effluent Substrate Concentration, BOD Conversion Factor & Net Waste Activated Sludge and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Theoretical Oxygen Requirement?
In this formula, Theoretical Oxygen Requirement uses Average Daily Influent Flow Rate, Influent Substrate Concentration, Effluent Substrate Concentration, BOD Conversion Factor & Net Waste Activated Sludge. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Theoretical Oxygen Requirement = Total BOD Utilized-(1.42*Mass of Organisms Wasted)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!