Superimposed Load given Unit Pressure Solution

STEP 0: Pre-Calculation Summary
Formula Used
Superimposed Load = (2*pi*Unit Pressure*(Slant Height)^5)/(3*(Distance between Pipe and Fill)^3)
P = (2*pi*Pt*(hSlant)^5)/(3*(H)^3)
This formula uses 1 Constants, 4 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
Variables Used
Superimposed Load - (Measured in Newton) - Superimposed Load Thermal Expansion Coefficient is a material property that is indicative of the extent to which a material expands upon heating.
Unit Pressure - (Measured in Pascal) - The Unit Pressure refers to a developed at any point in the fill at a depth of H below the surface.
Slant Height - (Measured in Meter) - The Slant Height refers to the height of a cone from the vertex to the periphery (rather than the center) of the base.
Distance between Pipe and Fill - (Measured in Meter) - The Distance between Pipe and Fill refers to the distance between the upper part of pipe to lower end of fill.
STEP 1: Convert Input(s) to Base Unit
Unit Pressure: 16 Pascal --> 16 Pascal No Conversion Required
Slant Height: 1.5 Meter --> 1.5 Meter No Conversion Required
Distance between Pipe and Fill: 3 Meter --> 3 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
P = (2*pi*Pt*(hSlant)^5)/(3*(H)^3) --> (2*pi*16*(1.5)^5)/(3*(3)^3)
Evaluating ... ...
P = 9.42477796076938
STEP 3: Convert Result to Output's Unit
9.42477796076938 Newton --> No Conversion Required
FINAL ANSWER
9.42477796076938 9.424778 Newton <-- Superimposed Load
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Pressure Due to External Loads Calculators

External Diameter of Pipe given Load Per Unit Length for Pipes
​ LaTeX ​ Go External Diameter = sqrt(Load per unit Length/(Pipe Coefficient*Specific Weight of Fill))
Pipe Coefficient given Load Per Unit Length for Pipes
​ LaTeX ​ Go Pipe Coefficient = (Load per unit Length/(Specific Weight of Fill*(External Diameter)^2))
Specific Weight of Fill Material given Load Per Unit Length for Pipes
​ LaTeX ​ Go Specific Weight of Fill = Load per unit Length/(Pipe Coefficient*(External Diameter)^2)
Load Per Unit Length for Pipes Resting on Undisturbed Ground on Cohesion Less Soil
​ LaTeX ​ Go Load per unit Length = Pipe Coefficient*Specific Weight of Fill*(External Diameter)^2

Superimposed Load given Unit Pressure Formula

​LaTeX ​Go
Superimposed Load = (2*pi*Unit Pressure*(Slant Height)^5)/(3*(Distance between Pipe and Fill)^3)
P = (2*pi*Pt*(hSlant)^5)/(3*(H)^3)

What is superimposed load ?

The load superimposed on the dead load of a building. The term is generally synonymous with live load, although a distinction is sometimes made between the superimposed dead load caused by movable partitions, etc., and the live load caused by people.

How to Calculate Superimposed Load given Unit Pressure?

Superimposed Load given Unit Pressure calculator uses Superimposed Load = (2*pi*Unit Pressure*(Slant Height)^5)/(3*(Distance between Pipe and Fill)^3) to calculate the Superimposed Load, The Superimposed Load given Unit Pressure is defined as the live load which is imposed on a structure. Superimposed Load is denoted by P symbol.

How to calculate Superimposed Load given Unit Pressure using this online calculator? To use this online calculator for Superimposed Load given Unit Pressure, enter Unit Pressure (Pt), Slant Height (hSlant) & Distance between Pipe and Fill (H) and hit the calculate button. Here is how the Superimposed Load given Unit Pressure calculation can be explained with given input values -> 9.424778 = (2*pi*16*(1.5)^5)/(3*(3)^3).

FAQ

What is Superimposed Load given Unit Pressure?
The Superimposed Load given Unit Pressure is defined as the live load which is imposed on a structure and is represented as P = (2*pi*Pt*(hSlant)^5)/(3*(H)^3) or Superimposed Load = (2*pi*Unit Pressure*(Slant Height)^5)/(3*(Distance between Pipe and Fill)^3). The Unit Pressure refers to a developed at any point in the fill at a depth of H below the surface, The Slant Height refers to the height of a cone from the vertex to the periphery (rather than the center) of the base & The Distance between Pipe and Fill refers to the distance between the upper part of pipe to lower end of fill.
How to calculate Superimposed Load given Unit Pressure?
The Superimposed Load given Unit Pressure is defined as the live load which is imposed on a structure is calculated using Superimposed Load = (2*pi*Unit Pressure*(Slant Height)^5)/(3*(Distance between Pipe and Fill)^3). To calculate Superimposed Load given Unit Pressure, you need Unit Pressure (Pt), Slant Height (hSlant) & Distance between Pipe and Fill (H). With our tool, you need to enter the respective value for Unit Pressure, Slant Height & Distance between Pipe and Fill and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.