Stroke Length of Axial Piston Pump Solution

STEP 0: Pre-Calculation Summary
Formula Used
Stroke Length of Piston Pump = Pitch Circle Diameter of Bore*tan(Swash Plate Inclination)
Ls = db*tan(θ)
This formula uses 1 Functions, 3 Variables
Functions Used
tan - The tangent of an angle is a trigonometric ratio of the length of the side opposite an angle to the length of the side adjacent to an angle in a right triangle., tan(Angle)
Variables Used
Stroke Length of Piston Pump - (Measured in Meter) - Stroke Length of Piston Pump is how far the piston travels within a cylinder.
Pitch Circle Diameter of Bore - (Measured in Meter) - Pitch Circle Diameter of Bore is the diameter of the bore of a piston pump.
Swash Plate Inclination - (Measured in Radian) - Swash plate inclination is the inclination of the swash plate with axis of cylinder.
STEP 1: Convert Input(s) to Base Unit
Pitch Circle Diameter of Bore: 0.1 Meter --> 0.1 Meter No Conversion Required
Swash Plate Inclination: 63.43 Degree --> 1.1070623445398 Radian (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Ls = db*tan(θ) --> 0.1*tan(1.1070623445398)
Evaluating ... ...
Ls = 0.199956820831798
STEP 3: Convert Result to Output's Unit
0.199956820831798 Meter --> No Conversion Required
FINAL ANSWER
0.199956820831798 0.199957 Meter <-- Stroke Length of Piston Pump
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Sagar S Kulkarni
Dayananda Sagar College of Engineering (DSCE), Bengaluru
Sagar S Kulkarni has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Chilvera Bhanu Teja
Institute of Aeronautical Engineering (IARE), Hyderabad
Chilvera Bhanu Teja has verified this Calculator and 200+ more calculators!

Piston Pumps Calculators

Theoretical Volumetric Displacement given Bore Diameter and Swash Plate Inclination
​ LaTeX ​ Go Theoretical Volumetric Displacement in Piston Pump = Number of Pistons*Area of Piston*Pitch Circle Diameter of Bore*tan(Swash Plate Inclination)
Piston Pump Constant K
​ LaTeX ​ Go Piston Pump Constant = (pi*Number of Pistons*Piston Diameter^2*Pitch Circle Diameter of Bore)/4
Theoretical Volumetric Displacement given Area of Piston and Stroke Length
​ LaTeX ​ Go Theoretical Volumetric Displacement in Piston Pump = Number of Pistons*Area of Piston*Stroke Length of Piston Pump
Stroke Length of Axial Piston Pump
​ LaTeX ​ Go Stroke Length of Piston Pump = Pitch Circle Diameter of Bore*tan(Swash Plate Inclination)

Stroke Length of Axial Piston Pump Formula

​LaTeX ​Go
Stroke Length of Piston Pump = Pitch Circle Diameter of Bore*tan(Swash Plate Inclination)
Ls = db*tan(θ)

What are the two major types of piston pumps?

The two major types of piston pumps are: 1. Axial piston pumps and 2. Radial piston pumps. This classification is based on their orientation.

How to Calculate Stroke Length of Axial Piston Pump?

Stroke Length of Axial Piston Pump calculator uses Stroke Length of Piston Pump = Pitch Circle Diameter of Bore*tan(Swash Plate Inclination) to calculate the Stroke Length of Piston Pump, Stroke Length of Axial Piston Pump formula is defined as a measure of the distance traveled by the piston in an axial piston pump, which is a critical parameter in determining the pump's performance and efficiency in hydraulic systems. Stroke Length of Piston Pump is denoted by Ls symbol.

How to calculate Stroke Length of Axial Piston Pump using this online calculator? To use this online calculator for Stroke Length of Axial Piston Pump, enter Pitch Circle Diameter of Bore (db) & Swash Plate Inclination (θ) and hit the calculate button. Here is how the Stroke Length of Axial Piston Pump calculation can be explained with given input values -> 0.373205 = 0.1*tan(1.1070623445398).

FAQ

What is Stroke Length of Axial Piston Pump?
Stroke Length of Axial Piston Pump formula is defined as a measure of the distance traveled by the piston in an axial piston pump, which is a critical parameter in determining the pump's performance and efficiency in hydraulic systems and is represented as Ls = db*tan(θ) or Stroke Length of Piston Pump = Pitch Circle Diameter of Bore*tan(Swash Plate Inclination). Pitch Circle Diameter of Bore is the diameter of the bore of a piston pump & Swash plate inclination is the inclination of the swash plate with axis of cylinder.
How to calculate Stroke Length of Axial Piston Pump?
Stroke Length of Axial Piston Pump formula is defined as a measure of the distance traveled by the piston in an axial piston pump, which is a critical parameter in determining the pump's performance and efficiency in hydraulic systems is calculated using Stroke Length of Piston Pump = Pitch Circle Diameter of Bore*tan(Swash Plate Inclination). To calculate Stroke Length of Axial Piston Pump, you need Pitch Circle Diameter of Bore (db) & Swash Plate Inclination (θ). With our tool, you need to enter the respective value for Pitch Circle Diameter of Bore & Swash Plate Inclination and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Stroke Length of Piston Pump?
In this formula, Stroke Length of Piston Pump uses Pitch Circle Diameter of Bore & Swash Plate Inclination. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Stroke Length of Piston Pump = Theoretical Volumetric Displacement in Piston Pump/(Number of Pistons*Area of Piston)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!